00-0181-008 P L U M B I N G N 0 T E S (Z�"V Revisions:
1. ALL WORK SHALL CONFORM WITH THE SOUTH FLORIDA BUILDING CODE, NFPA, NEC, _ _ - _ ` O
KEY NOTES .
AND ALL OTHER APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS AND = _ _ _ ♦ 2
ORDINANCES. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR THE O �' ♦ 1 -1/2"V 10 EXISTING WASTE AND VENT STACK TO REMAIN
COMPLETION OF THE PLUMBING SYSTEMS DESCRIBED HEREIN AND SHOWN ON THE - - 2 ♦�
DRAWINGS. 1 -1/'.yv �',� IN PLACE.
2. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, INSPECTIONS, - __ _ - - 400400
_ 1
TESTS, PERFORMANCE BONDS, FINES AND OTHER ITEMS AS REQUIRED FOR THE - 1 2 EXISTING VENT PIPING TO REMAIN IN PLACE.
INSTALLATION OF THE COMPLETE PLUMBING SYSTEMS, AND SHALL BE RESPONSIBLE
FOR OBTAINING HIS OWN PERMIT. 1-1/2"V r `�♦ 2
3. CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST I `00 - " I O3 EXISTING COLD AND HOT DOMESTIC WATER �' Z rn
PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. I 1`1�Z V I TO REMAIN IN PLACE. U t0
4. EXCEPT WHERE LONGER WARRANTIES ARE SPECIFIED FOR SPECIFIC EQUIPMENT, I �� 1 1 DOUBLE SINK (0 m M
CONTRACTOR SHALL WARRANT ALL WORK TO BE FREE OF DEFECTS IN WORKMANSHIP I LAS/-H OI ® REPLACE EXISTING FIXTURES WITH NEW � rr 11
AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER FINAL WRITTEN ACCEPTANCE OF I FIXTURES. Q V d.
THE PROJECT BY THE OWNER.
Q�
5. SUBMIT SHOP DRAWINGS FOR ALL MATERIALS AND EQUIPMENT FOR ACCEPTANCE OF O I 3 FD 5 NEW FIXTURES.
THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLA- r, F 9 2 W w r.
TION OF ANY EQUIPMENT AND MATERIALS. I "W CO to
{h FL. 6 NOT USED. Ir�
6. PRODUCTS AND MATERIALS SPECIFIED BY TRADE NAME AND/OR MODEL ON THE W.C. �' O ® �
DRAWINGS ESTABLISH 'A STANDARD OF QUALITY, APPEARANCE PERFORMANCE AND
DIMENSIONS. CONTRACTOR SHALL BASE HIS BID ON THOSE ITEMS, WHICH SHALL BE CO 2"W I 3"W O7 NOT USED. Zv
CONSIDERED TO ESTABLISH A STANDARD BASIS OF BIDDING. REQUESTS FOR F�. 1 I SINK 3"W
SUBSTITUTION SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT/ENGINEER DOUBLE SINK I ® EXISTING PIPE CHASE e`er
DEMONSTRATING THAT THE PROPOSED PRODUCT IS COMPARABLE, AND THAT BASIC
DESIGN, CONSTRUCTION STANDARDS, QUALITY AND WARRANTIES ARE EQUAL OR T H
BETTER THAN THE PRODUCT SPECIFIED. CONTRACTOR SHALL BE RESPONSIBLE FOR O EXISTING ROOF DRAIN
ANY CHANGE IN THE WORK REQUIRED BY OTHER TRADES AND SHALL PAY FOR ANY
EXPENSES INCURRED DUE TO THE CONTRACTOR'S REQUEST FOR REVISIONS OR
SUBSTITUTIONS. CO
7. PROVIDE ALL NEW MATERIALS OF AMERICAN MANUFACTURE, BEARING THE U.L. LABEL , N
AS APPLICABLE. PROVIDE SUPPLEMENTAL MATERIALS NOT SPECIFICALLY NOTED
{h �.
HEREIN, BUT REQUIRED TO COMPLETE THE INSTALLATION IN ACCORDANCE WITH THE
INTENT OF THE CONTRACT DRAWINGS, AT NO ADDITIONAL COST TO THE OWNER. 2"W
N
8. FURNISH ALL NECESSARY ACCESS PANELS TO CONTROL VALVES, ETC., TO THE ►►����
GENERAL CONTRACTOR, FOR INSTALLATION UNDER THE GENERAL TRADES.
9. ALL WORK SHALL BE FIELD CHECKED BEFORE INSTALLATION AND COORDINATED WITH W
-
ALL OTHER TRADES. THE CONTRACT DRAWINGS ARE DIAGRAMMATIC AND INTENDED �
TO DEPICT APPROXIMATE EQUIPMENT LOCATIONS AND ARRANGEMENTS, NOT SHOW BASTE & VENT RISER DIAGRAM LABORATORY #1
Zp
ANY MINOR DETAIL. PLANS SHALL NOT BE SCALED: REFER TO THE ARCHITECTURAL N.T.S. 0
AND STRUCTURAL DRAWINGS FOR DIMENSIONS.
10. OFFSET PIPING AS REQUIRED TO CLEAR BUILDING STRUCTURE, DUCTWORK, ETC. AS
ALL
SHOWN ON DRAWINGS AND AS REQUIRED BY FIELD CONDITIONS.
11. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT PLUMBING FIXTURE CONNECTION SCHEDULE
JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. F-7
12. FURNISH AND INSTALL PLUMBING FIXTURES SELECTED BY THE TENANT. UNLESS PLUMBING LEGEND N 0. DESCRIPTION DRAIN C 0 D WATER HOT REMARKS
OTHERWISE SPECIFIED, FIXTURES SHALL BE FIRST QUALITY WHITE VITREOUS CHINA
WITH CHROME PLATED BRASS OR BRONZE TRIMMING.
FLUSH TANK, 1.6 GPF, H.C. HEIGHT M
13. EACH PLUMBING FIXTURE SHALL BE PROVIDED WITH AIR CHAMBERS AS PER S.F.B.C. W.C. WATER CLOSET (ELONGATED, H.C.) 3" 1/2##
-- D rn
ELONG. OPEN FRONT SEAT W/ COVER O
14. PROVIDE SHUT-OFF VALVE(S) FOR EACH LABORATORY AND FOR EACH FIXTURE. SANITARY WASTE (W) w O j
15. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE ____ LAV-A LAVATORY (COUNTER TOP) 1 1/4': 1/2" 1/2" PROVIDE 2.0 GPM FAUCET J LL.PROVIDED TO CONNECT BOTH TYPES OF PIPES. SANITARY VENT (V) Z E-1 O W
16. PROVIDE PIPING AS FOLLOWS: - DOMESTIC COLD WATER CW LAV-H LAVATORY (WALL MOUNTED, H.C.) 1 1/4 1/2 1/2" PROVIDE 2.0 GPM FAUCET Q
A. DOMESTIC COLD, HOT AND FILTERED WATER: TYPE L SEAMLESS HARD DRAWN ( )
COPPER TUBE WITH CAST COPPER ALLOY OR WROUGHT SOLDER JOINT FITTINGS. PROVIDE 2.5 GPM FAUCET
- - - - DOMESTIC HOT WATER HW / " / " /
( ) SINK DOUBLE KITCHEN SINK 1 2 1 2 1 1 2 GOOSENECK SPOUT, 4" WRIST BLADES W N m
SOLDER USED IN JOINTS SHALL BE 100 LEAD-FREE. � Q �
B. SANITARY WASTE AND VENT PIPING: CAST IRON NO-HUB PIPE AND FITTINGS FILTERED WATER (FW) DOUBLE DOUBLE COMPARTMENT SINK 1 1/2" /2" 1/2" PROVIDE 2.5 GPM FAUCET ~' [-� w
WITH NEOPRENE GASKETS AND STAINLESS STEEL DRAW BAND JOINT SEALS. SINK 1 GOOSENECK SPOUT, 4" WRIST BLADES W ►�
17. DISINFECT DOMESTIC WATER PIPING IN ACCORDANCE WITH SFBC AND AWWA -X- AM i90115 U!J DM i Wry
18. THERMAL INSULATION: DOMESTIC HOT WATER PIPING: 1/2" THICK PRE-MOLDED GLASS AT 4407 tt '
FIBER PIPE INSULATION WITH SELF-ADHESIVE JACKET. I IN 0%_:I?R!0OR CEILING TO LAB #2 O Q
19. CLEANOUTS Z o
A. WALL CLEANOUT: JOSAM SERIES 58790 WITH THREADED PLUG AND VANDAL ® O O Q Ir
PROOF STAINLESS STEEL ACCESS COVER PLATE.
B. FLOOR CLEANOUT: cJ(� �' � T , a R�
1�&�m�z CaN Grra) 9 p 0 .'
INTERIOR; JOSAM SERIES 56020 WITH VANDAL PROOF COVER. .TD .14r', w 4a-�' O m
PROVIDE CLEAN-OUTS IN HORIZONTAL PIPING AT INTERVALS REQUIRED BY CODE, AT MEN+! �� 13/4"FW I g W Z Q
THE BOTTOM OF ALL WASTE STACKS AND RISERS, AND AT EVERY CHANGE IN 211V
DIRECTION, AND WHERE INDICATED ON DRAWINGS. I i /4"CW 374 H �,
20. DRAINS: TOILET ROOM.FLOOR DRAIN (FD-1): JOSAM NO. 30000-6S-50, 6" X 6" NICKEL- / „
BRONZE STRAINER AND TRAP PRIMER CONNECTION. 1/2„HW 3 4 CW E---q I I 3 4"HW O ~ W
21. CARRIERS: j- 3/4"H 3 - - I / HOOD C\2 �
A. ALL CARRIERS SHALL BE FULLY BOLTED TO THE FLOOR AND INSTALLED AS N
RECOMMENDED BY MANUFACTURER. 1 2 W " FD 1/2"HW Z w
B. LAVATORIES H.C. : JOSAM SERIES 17100-67 RECTANGULAR STRUCTURAL STEEL 4 - /
UPRIGHTS WITH INTEGRAL WELDED HEAVY STEEL FOOT DUCTILE IRON DOUBLE N Z
CONCEALED ARMS FOR WHEELCHAIR FIXTURE. S I 713/4' 2 'V ~
I Q W
22. VALVES I 1 4 LAV-H DOUBLE SINK � U
A. GATE VALVES: ALL BRONZE CONSTRUCTION, SOLID WEDGE, CLASS 125, 200 PSIG I 1 /2 FW Z O Q g
NON-SHOCK WATER, THREADED ENDS, MILWAUKEE 115. 1 11 1/2„FW 0 0-
B. GLOBE VALVES: SOLDERED ENDS, MILWAUKEE 1502.
r II I
�
23. HANG PIPING FROM STRUCTURE UTILIZING GALVANIZED HANGER RODS AND TRAPEZE i I-�--I C
OR CLEVIS HANGERS. FOR COPPER PIPING, RODS AND HANGERS SHALL BE COPPER
CLAD. SUPPORT PIPING INDEPENDENTLY FROM EQUIPMENT. PLACE HANGERS AT IO 1 E"i
EVERY PIPE CHANGE OF DIRECTION AND AT EACH SIDE OF SHUT OFF VALVES. PROVIDE I i w
PROTECTING SHEET METAL SHIELDS FOR ALL INSULATED PIPING. I I I m O
24. PIPING TESTS HOOD 1/2 "HW I I I E UD
SANITARY PIPING: SUBJECT ENTIRE SYSTEM TO A HYDROSTATIC HEAD OF NO LESS / II 2"V 1/2„FW C fn
THAN 10 FEET OF WATER EXCEPT FOR THE TOPMOST 10 FEET OF PIPE BY FILLING 'L_ _ v O
SYSTEM WITH WATER UP TO THE OVERFLOW POINT OF THE HIGHEST OPENING, FOR A M
PERIOD OF TWO HOURS WITHOUT DROP IN WATER LEVEL. �+
M
DOMESTIC WATER PIPING: SUBJECT THE ENTIRE SYSTEM TO A HYDROSTATIC 1 a 114,
PRESSURE OF NO LESS THAN 150 PSIG FOR A PERIOD OF TWO HOURS WITHOUT LOSS
IN PRESSURE.
LAV-A
25, TEST ALL EQUIPMENT TO DEMONSTRATE PROPER FUNCTIONING AND CAPACITY. SINKO O
26. PROVIDE SHOCK ABSORBERS, DIELECTRIC FITTINGS, HANGERS AND INSERTS, TRAP RE-
5 .t
SEALERS, VACUUM BREAKERS, STRAINERS, VALVES, ETC., FOR COMPLETE AND
OPERABLE PLUMBING SYSTEMS AS REQUIRED BY CODE AND AS INDICATED ON PLANS. C 'v
PROVIDE UNIONS AND FLANGES AT ALL CONNECTIONS TO EQUIPMENT FOR EASY ca Z
MAINTENANCE AND DISMANTLING. PROVIDE ESCUTCHEONS AT ALL PIPE PENETRATIONS m a
OF WALLS, PARTITIONS, FLOORS AND CEILINGS. •�p v p
O
O �
Q pN C C
C O
PLUMBING FLOOR PLAN - LABORATORY #1
NORTH ° ` 3
SCALE: 1 /4" = 1 '-0" .� � � o.
Lagomasino &-Associates, P.A sheet no.
Consulting EngineeV,
FLORIDA P.E. # 1,783 - - MECHANICAL
814 PONCE DE LEOA'QLVDN.". 17 R I �fEL.:(305) 444-0867 of 'I
CORAL GABLES, FL. 33t343 T ^ j E 0 FFAX:(305)1441-6979