00-0176-012 Revisions: o) QU c�D PAIR 18AWG TWISTED VARIABLE FREOUENCY 3PA1R 1SAWG TWISTED SHIELDED FOR: VFD CONTROLLER (PROVIDED BY M.C.) SHIELDED FOR: W M ) Aj SrEEdSTOP fC-URRENT )SPEED CONTROL )) O )SPEED REFERENCE C SPEED REEFEERENCE //y � 1/ '^ VARIABLE FREQUENCY LL V c 4! CONTROLLER (BY M.C.) VFD HAWKEYE G SWTG{T Q AIR MEAS URING STATION SUPPLY O X r- DEa N DAMPER -• SENSOA FAN Ey t AIR COOLED ® L~L rte, r CONDENSING UNIT Zv A FIRE ALARM AIR UNIT STARTER W/ 24VAC T O W/BLUE INTERLOCK TRANSFORMER �- R�T3 D FAN STATUS L AIR I �� Y Y W/Y SENSOR �_ RIBUIC H-800 CURRENT RELAY H A SENSOR W/BLUE Q � IN2 �J 7n fT1 GND W/Y Y GND FILTER I o o SUPPLY AIR (° V) _ — STATUS T i I FAN TO ROOM D/P R G '0 MANUAL DBL-205B SUPPLY12A R N VOLUME DIFFERENTIAL INS COM SENSOR (0 ❑UTSIDE AIR IN3 GND PRESSURE SWITCH DAMPER STE-1205 SENSOR C"CCAL,OF 3) RETURN AIR W Q -- SENS❑R GND � Z KMC ❑UTSIDE AIR 120 VAC IN4 4 PAIR r 0 CONTROL CIRCUIT 120/24 VAC KMD-6904 TWISTED PAIR �] I�J CONTROL TRANSFORMER RETURN AIR SHIELDED F�� L- CONNECTION CONTROLLER WIRE TO NEXT UNIT z, ", 0 �r+10� AIR UNIT CONTROL WIRING D IAG RAM ®zZ�ZCDl= 1I- tea"- 0a TWISTED 120 VAC (7) PAIR M TPB-202 W) SHIELDED � WIRE 120/24VAC p M TRANSFORMER CONTROL ENCLOSURE w O FROM PREVIOUS z La. WIRING DIAGRAM FOR STAND-ALONE UNIT DUCT DETECTORS WHERE NO FIRE DUCT All BLOWER " W O Z ALARM SYSTEM IS PROVIDED] AS THE ENERGY MANAGEMENT SYSTEM SHALL CONTROL THE COOLING Y Q BASED ON THE ZONE REQUIRING THE MOST AMOUNT OF V PER NFPA-90A ARTICLE 4-4. COOLING KMD-1101 NET SENSOR w N m DUCT DETECTOR - SYSTEM ~ Q W SENSOR DH400ACDC-P. TYPICAL AHU INTERLOCK SCHEMATIC A/C POWER: CONNECT TO A 120-V i 04 UNSWITCHED BRANCH CIRCUIT. Q BLOWER STARTER zo SHUTDOWN CONTACTS. ix AUDIOVISUAL REMOTE ANNUNCIATOR HORN p OJ AND TEST PANEL - SYSTEM SENSOR LOCATE PANEL IN a L. APA451, ` ' ` ' RECEPTION AREA. m ,O. /0, GREEN RED g W z Q E-1 2 DUCT DETECTOR WIRING SCHEMATIC N E w U N o � TO NEXT CONTROLLER 4 120 VAC 120VAC/24VAC Z di H KMD -5501 TRANSFORMER MER KMD-6904 TRANSFORMER w CONTROLLER 120VAC CONTROLLER 120VAC E" Q W HOFFMAN CONTROL ENCLOSURE 12"H, 12"W, 4"D 8 X 8 CONTROLLER W/ TIME CLOCK ~ � U SEE SHEET AC-2 FOR DETAIL PIPING OF SYSTEM WORK INCLUDED WITH LAB #1 WORK INCLUDED WITH LAB #2 KMD-1101 NET SENSOR Z O Q COMPONENTS. SEE PLANS FOR PIPE SIZES. KMD-6904 1P TYPICAL LR24 ~ �+ �0N a. D NEXT CONTROLLER HW RETURN COMMUNICATION LAN TO ALL w DEVICE 1y1 THREE WAY TWO CONTROLLERS C n� HOT WATER mw r, cq EXPANSION TANK m< = =� ���� N VALVE WAITI13N LOT w 9 &1(12 GALLONS) a®®®®® ®® I HW SUPPLY •• 1, 1 RJ-11 CONNECTION 1/2 — COMMUNICATIONS p REHEAT WATER RETURN FROM PREVIOUS 120VAC = N DEVICE 18AWG TWISTED PAIR T-255-120 120/24VAC "~ SHIELDED WIRE V O REHEAT WATER SUPPLY I TRANSFORMER o M AIR UNIT 1 120VAC DOMESTIC MAKE UP o S/S ON CIRCULATING REHEAT COIL PUMP RC RC o TEMP 74.0 0 120VAC/24VAC AC � (TYP) �"'0 TRANSFORMER °coo° NOTE: PLEASE VERIFY THAT THE INTERNAL TRANSFORMER HAS A 24V SECONDARY KMD-1001 NETVIEW CONTROLLER I KMD-1101 NET COMMUNICATING TO ALL DEVICES SENSOR RC ( RC 3 m a PUN RELIEF TO DISCHARGE WH RUN TYPICAL REHEAT COIL CONTROL WIRING EMS RISER WIRING DIAGRAM ° OVER JANITOR SINK WATER HEATER IN 3RD FLOOR � .. o c RC RC � � N C c DRAIN PAN RUN DRAIN TO } �. m 6 DISCHARGE OVER LABORATORY #1 LABORATORY #2 "v° 'v° �a JANITOR SINK IN 3RD FLOOR Lagomasil & Associates, P.A Sheet no. REHEAT SYSTEM PIPING SCHEMATIC Consultin4,:E�naIn�eerk..... . N.T.S. FLORIDA P.E.•3 -tWe72 ! HANICAL AC - 3 814 PONCE DE SON �tVl7 , z Tff.:(305) 444-0867 of 3 CORAL GABLES, T'E.:331 J4A j F A f AX:(305.) 441-6979