Loading...
00-0176-008 PLUMBING NOTES KEY DOTES : _ A Revisions 1. ALL WORK SHALL CONFORM WITH THE SOUTH FLORIDA BUILDING CODE, NFPA, NEC, 1 AND ALL OTHER APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS AND (2 ORDINANCES. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR THE COMPLETION OF THE PLUMBING SYSTEMS DESCRIBED HEREIN AND SHOWN ON THE r�'� �' 1 2"V DRAWINGS. 1 - - - ��` 0�4�` 1 0 EXISTING WASTE AND VENT STACK TO REMAIN 2. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, INSPECTIONS, 12"V Amy cIN PLACE. TESTS, PERFORMANCE BONDS, FINES AND OTHER ITEMS AS REQUIRED FOR THE `` _ �.y +! INSTALLATION OF THE COMPLETE PLUMBING SYSTEMS, AND SHALL BE RESPONSIBLE ' 0'< I O2 EXISTING VENT PIPING TO REMAIN IN PLACE. FOR OBTAINING HIS OWN PERMIT. 1 -` r**ft` 2 1 3. CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST /� 1 12"V PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 2 �� I r� ' O3 EXISTING COLD AND HOT DOMESTIC WATER _0) �> 12 V 1 ��� I I TO REMAIN IN PLACE. o� � 0 c0 4. EXCEPT WHERE LONGER WARRANTIES ARE SPECIFIED FOR SPECIFIC EQUIPMENT, 10"'000 I 6 N CONTRACTOR SHALL WARRANT ALL WORK TO BE FREE OF DEFECTS IN WORKMANSHIP Q�000� �� ��2 V O (0 AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER FINAL WRITTEN ACCEPTANCE OF �� ( DOUBLE SINK I 2O �� 1 ® REPLACE EXISTING FIXTURES WITH NEW •. r � THE PROJECT BY THE OWNER, r�� 12"V CO r N �� I LSINK 1 FIXTURES. Q V Q It 5. SUBMIT SHOP DRAWINGS FOR ALL MATERIALS AND EQUIPMENT FOR ACCEPTANCE OF I 1 O qth F I �0) THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLA- 2"V FL' 5 NEW FIXTURES. TION OF ANY EQUIPMENT AND MATERIALS. I I � ` CO 4th 2 W SINK 0 =� 6. PRODUCTS AND MA 1 1 � ~O DRAWINGS ESTABLSHRIALSTANDARD OF QUALITY. APPEARANCE, PERFORMANCE AND 1 2'v 1 2"V�� 2"W © RUN NEW WASTE AT THE CEILING OF THE FLOOR 0 ov DIMENSIONS. CONTRACTOR SHALL BASE HIS BID ON THOSE ITEMS. WHICH SHALL BE i IO O 10 BELOW. Z CONSIDERED TO ESTABLISH A STANDARD BASIS OF BIDDING. REQUESTS FOR SUBSTITUTION SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT/ENGINEER I 2"W DEMONSTRATING THAT THE PROPOSED PRODUCT IS COMPARABLE, AND THAT.BASIC. W.C. 1 nth r�• �7 NEW VENT PIPING. CONNECT TO EXISTING VENT. DESIGN, CONSTRUCTION STANDARDS, QUALITY AND WARRANTIES ARE EQUAL OR RELOCATE EXISTING ° BETTER THAN THE PRODUCT SPECIFIED. CONTRACTOR SHALL BE RESPONSIBLE FOR I 3" $ EXISTING PIPE CHASE H ANY CHANGE IN THE WORK REQUIRED BY OTHER TRADES AND SHALL PAY FOR ANY 3'+W 1O STACKS AT CEILING OF EXPENSES INCURRED DUE TO THE CONTRACTOR'S REQUEST FOR REVISIONS OR 3rd FL AS REQUIRED. 3 FD " SUBSTITUTIONS. CO 3 W 9 EXISTING ROOF DRAIN 7. PROVIDE ALL NEW MATERIALS OF AMERICAN MANUFACTURE, BEARING THE U.L. LABEL 3"W LAV-H WASTE & VENT RISER DIAGRAM - LABORATORY #2 AS APPLICABLE. PROVIDE SUPPLEMENTAL MATERIALS NOT SPECIFICALLY NOTED N.T.S. 1 O NEW WASTE PIPING to HEREIN, BUT REQUIRED TO COMPLETE THE INSTALLATION IN ACCORDANCE WITH THE INTENT OF THE CONTRACT DRAWINGS, AT NO ADDITIONAL COST TO THE OWNER. 2"W 8. FURNISH ALL NECESSARY ACCESS PANELS TO CONTROL VALVES, ETC., TO THE N GENERAL CONTRACTOR, FOR INSTALLATION UNDER THE GENERAL TRADES. (0 9. ALL WORK SHALL BE FIELD CHECKED BEFORE INSTALLATION AND COORDINATED WITH PLUMBING FIXTURE CONNECTION SCHEDULE ALL OTHER TRADES. THE CONTRACT DRAWINGS ARE DIAGRAMMATIC AND INTENDED �y LtJ Q TO DEPICT APPROXIMATE EQUIPMENT LOCATIONS AND ARRANGEMENTS, NOT SHOW PLUMBING LEGEND WATER w z o ANY MINOR DETAIL. PLANS SHALL NOT BE SCALED: REFER TO THE ARCHITECTURAL N O. D S R I P T - AND STRUCTURAL DRAWINGS FOR DIMENSIONS. E C ION DRAIN COLD HOT REMARKS M O� 10. OFFSET PIPING AS REQUIRED TO CLEAR BUILDING STRUCTURE, DUCTWORK, ETC. AS „ FLUSH TANK, 1.6 GPF, H.C. HEIGHT Is.OJ SHOWN ON DRAWINGS AND AS REQUIRED BY FIELD CONDITIONS. SANITARY WASTE W W.C. WATER CLOSET (ELONGATED, H.C.) 3 1/2 -- ELONG. OPEN FRONT SEAT W COVER ILL 11. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. -------- SANITARY VENT (V) LAV-A LAVATORY (COUNTER TOP) 1 1/4': 1/2' 1/2" PROVIDE 2.0 GPM FAUCET 12. FURNISH AND INSTALL PLUMBING FIXTURES SELECTED BY THE TENANT. UNLESS a OTHERWISE SPECIFIED, FIXTURES SHALL BE FIRST QUALITY WHITE VITREOUS CHINA _ WITH CHROME PLATED BRASS OR BRONZE TRIMMING. DOMESTIC COLD WATER (CW) LAV-H LAVATORY (WALL MOUNTED, H.C.) 1 1/4' 1/2" 1/2" PROVIDE 2.0 GPM FAUCET d 13. EACH PLUMBING FIXTURE SHALL BE PROVIDED WITH AIR CHAMBERS AS PER S.F.B.C. C M - - DOMESTIC HOT WATER (HW) SINK DOUBLE KITCHEN SINK 1 1/2" 1/2" 1/2� PROVIDE 2.5 GPM FAUCET o 14. PROVIDE SHUT-OFF VALVE(S) FOR EACH LABORATORY AND FOR EACH FIXTURE. GOOSENECK SPOUT, 4" WRIST BLADES • 15. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE FILTERED WATER (FW) DOUBLE PROVIDE 2.5 GPM FAUCET 3 PROVIDED TO CONNECT BOTH TYPES OF PIPES. DOUBLE COMPARTMENT SINK 1 1/2" 1/2" 1/2" J SINK GOOSENECK SPOUT, 4 WRIST BLADES Z Z 16. PROVIDE PIPING AS FOLLOWS: A. DOMESTIC COLD, HOT AND FILTERED WATER: TYPE L.SEAMLESS HARD DRAWN COPPER d' Q TUBE WITH CAST COPPER ALLOY OR WROUGHT SOLDER JOINT FITTINGS. 4 ' ` '"_Wp�L& 715 A--r ry �, i-�-I SOLDER USED IN JOINTS SHALL BE 100% LEAD-FREE. REMOVE EXISTING N m� Q } B. SANITARY WASTE AND VENT PIPING: CAST IRON NO-HUB PIPE AND FITTINGS WATER CLOSET STUB LAJ WITH NEOPRENE GASKETS AND STAINLESS STEEL DRAW BAND JOINT SEALS. OUT AND BEND, PLUG w � � 17. DISINFECT ALL DOMESTIC WATER PIPING IN ACCORDANCE WITH SFBC AND AWWA OR REMOVE PIPING - STANDARDS. UNDER THE FLOOR 18. THERMAL INSULATION: DOMESTIC HOT WATER PIPING: 1/2" THICK PRE-MOLDED GLASS SLAB AND FILL SLAB HOOD FIBER PIPE INSULATION WITH SELF-ADHESIVE JACKET. OPENING WITH N Q 19. CLEANOUTS CONCRETE TO MATCH • 11/2 z A. WALL CLEANOUT: JOSAM SERIES 58790 WITH THREADED PLUG AND VANDAL EXISTING. PROOF STAINLESS STEEL ACCESS COVER PLATE. 0 DOUBLE SINKO B. FLOOR CLEANOUT: Q N (y INTERIOR; JOSAM SERIES 56020 WITH VANDAL PROOF COVER. ix PROVIDE CLEAN-OUTS IN HORIZONTAL PIPING AT INTERVALS REQUIRED BY CODE, AT HOO 3+ D W C _ m �' W THE BOTTOM OF ALL WASTE STACKS AND RISERS, AND AT EVERY CHANGE IN „ -� �� 6 I Q Q DIRECTION, AND WHERE INDICATED ON DRAWINGS. 1/2 C 1 2 FW I w Z 20. DRAINS: TOILET ROOM FLOOR DRAIN (FD-1): JOSAM N0. 30000-6S-50, 6" X 6" NICKEL- 1 2"HW RELOCATE EXIST E _I '-' BRONZE STRAINER AND TRAP PRIMER CONNECTION. 6 I WASTE STACK �D �� 21. CARRIERS: O I O 2"V O 1 2"V O� 2"V -- -----J- --------� --��--------L E-i w 0 A. ALL CARRIERS SHALL BE FULLY BOLTED TO THE FLOOR AND INSTALLED AS LA _ _ _ _ _ m RECOMMENDED BY MANUFACTURER. 1/2"HW v-H 3/4"HW I 3/4"FW 3/4"FW z N B. LAVATORIES (H.C.): JOSAM SERIES 17100-67 RECTANGULAR STRUCTURAL STEEL I 2O I 3/4"HW 1 1/2"HW ' w UPRIGHTS WITH INTEGRAL WELDED HEAVY STEEL FOOT, DUCTILE IRON © O CONCEALED ARMS FOR WHEELCHAIR FIXTURE. I REMOVE EXIST. Z � F- i 22. VALVES 2�+�--{a-'--i DOMESTIC COLD Q � W I I WATER PIPING IN 170 SIN E-1 ~ 0 A. GATE VALVES: ALL BRONZE CONSTRUCTION, SOLID WEDGE, CLASS 125, 200 PSIG O I I THIS AREA. II � � J 0-NON-SHOCK WATER, THREADED ENDS, MILWAUKEE 115. I 1 ` OD Q _ B. GLOBE VALVES: SOLDERED ENDS, MILWAUKEE 1502. 1 O „ NN 23. HANG PIPING FROM STRUCTURE UTILIZING GALVANIZED HANGER RODS AND TRAPEZE 3/4 FW I /2 FW F�--I -a OR CLEVIS HANGERS. FOR COPPER PIPING, RODS AND HANGERS SHALL BE COPPER 3/4"CW I ( I 2'�V W N CLAD. SUPPORT PIPING INDEPENDENTLY FROM EQUIPMENT. PLACE HANGERS AT PACKAGED DOMESTIC E--i EVERY PIPE CHANGE OF DIRECTION AND AT EACH SIDE OF SHUT OFF VALVES. PROVIDE / ++ (0 PROTECTING SHEET METAL SHIELDS FOR ALL INSULATED PIPING. -1- -�Q- FW TO LAB #1 3/4 HW _ 1 WATER FILTER SINK 5 m � PROVIDED BY O 0 O 3 24, PIPING TESTS FW TO LAB #2 I COLD WATER STIC EXIST. COLD AND HOT WATER OWNER, INSTALLED v • SANITARY PIPING: SUBJECT ENTIRE SYSTEM TO A HYDROSTATIC HEAD OF NO LESS BY-PASS RISERS. BY CONTRACTOR. THAN 10 FEET OF WATER EXCEPT FOR THE TOPMOST 10 FEET OF PIPE BY FILLING SYSTEM WITH WATER UP TO THE OVERFLOW POINT OF THE HIGHEST OPENING, FOR A pm PERIOD OF TWO HOURS WITHOUT DROP IN WATER LEVEL. U M DOMESTIC WATER PIPING: SUBJECT THE ENTIRE SYSTEM TO A HYDROSTATIC PRESSURE OF NO LESS THAN 150 PSIG FOR A PERIOD OF TWO HOURS WITHOUT LOSS REMOVE UNUSED CL IN PRESSURE. 25. TEST ALL EQUIPMENT TO DEMONSTRATE PROPER FUNCTIONING AND CAPACITY. 3/4"FW TO LABORATORY No. 2O WASTE, COLD AND 1 . RUN INSIDE CORRIDOR HOT WATER PIPING IN 26. PROVIDE SHOCK ABSORBERS, DIELECTRIC FITTINGS, HANGERS AND INSERTS, TRAP RE- CEILING. 3/4 DOM AND THIS AREA. '• SEALERS, VACUUM BREAKERS, STRAINERS, VALVES, ETC., FOR COMPLETE AND I FILTERED WATER DN •° " •° OPERABLE PLUMBING SYSTEMS AS REQUIRED BY CODE AND AS INDICATED ON PLANS. PROVIDE UNIONS AND FLANGES AT ALL CONNECTIONS TO EQUIPMENT FOR EASY I TO FILTER UNIT. c 'v MAINTENANCE AND DISMANTLING. PROVIDE ESCUTCHEONS AT ALL PIPE PENETRATIONS I ❑ WATER FILTER o o, OF WALLS, PARTITIONS, FLOORS AND CEILINGS. P r a � � v L - L o O O M p N C C 0 G m WT PLUMBING FLOOR PLAN - LABORATORY #2 m a ITATER FILTER PIPING SCHEMATIC NORTH SCALE: 1 /4" - l '-o" � a I N.T.S. , Lagomas' oL&,�� sociates, P.A She®t no. Consultinc��'En'gi eer� ` F �,''•, FLORIDA P.E. TT872 P • 814 PONCE D�, LfaN I A T E 0 F,CE1..4305) 444-0867 Of CORAL GABLES;FL?.3313 ' ,"FAX:(305) 441-6979 A L