ELECTRICAL RISER DIAGRAM E William Friedman, R.A. a
AR 0002115 pA
I{- GFI STRIP
D W.
I LIGHTS
1 �a
a SINK E
26 Get 3
O.H. ELEC. SERVICE 14,1s
II
-3/0 THW IN --4-f2" C. 0 I E E
E E RANGE pl =
200 AMP DISC. 200 AMP. PANEL 42 CB PANEL 27 29 Glt 25
XIST
ANEL
M REF. REF. PANTRY,,/ ,/
ELECT. METER 3-3/0 THW CU. IN 1 - 1 /2" COND.
4j
1 #4 -THW. COPPER IN 3/4" 1
CONDUIT TO COLD WATER LINE
OW
AND SLAB REBAR I�
AND (2) 5/8" COPPER CLAD f Q,
" STEEL RODS DRIVEN INTO THE ;
MIN. GROUND 10' MIN. DISTANCE
BETWEEN RODS `SHALL BE NOT
LESS THAN 6'. a
TABLE GFI SINK 2 H
28 - '
0
SD
13,15
TYPE ITE EQ
SERVICE 240V-10-3W EXISTING = _ MAIN BUS 225 �( x
NEUTRAL FULL
MOUNTING : SURFACE MAINS MCO (225)
PANEL +30 P
SECURITY AND FORCED ENTRY PREVENTION: POLES . 42 A.I.C.AIC ; 10K 21.23 - - -
VP DEM N0. DEM TRIP CON- WIRE REMARKS CKT. CKT. REMARKS WIRE CON- TRIP N0. DEM DEM '
1. PROVIDE INTRUSION AND BURGLARY SECURITY DEVICES AS SET FORTH K.V.A. K.V.A. POLE DUIT NO. NO. DUIT- POLE K.V.A. K.V.A
IN CHAPTER 36 OF THE SOUTH FLORIDA BUILDING CODE. . 30
I j
3.0 1.0 15-1 1/2" #14 STRIP LIGHTS 1 2 WASHER #12 1/2" 20-1 1.5 C
2. ALL LOCKS ON INTERIOR DOORS SHALL BE CAPABLE OF RESISTING A I 30 28 C:
FORCE OF 300 LB. APPLIED IN ANY MOVEABLE DIRECTION AND IN 1.5 20-1 1/2" #12 KITCHEN GFI 3 4 DINING GFI #12 1/2" 20-1 1.5 I
ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN THE SOUTH 1.0 15-1 1/2" #14 LITES & RECEP. 5 6 � 30'��
FLORIDA BUILDING CODE. LITES & RECEP. #14 1/2" 15-1 1,5 ]��v 0
3. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY 1.0 15-1 1/2- #14 LITES & RECEP. 7 8 LITES & RECEP. #14 1/2" 15-1 1.5 - - - - 32
OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6000 POSSIBLE 1.0 15-1 1/2" #14 LITES & RECEP. 9 10 LITES & RECEP, #14 1/2" 15-1 C)
KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH 1.5 30
HARDENED BOLT INSERTS. 1.0 15-1 1/2" #14 LITES & RECEP. 11 12 POOL PUMP #12 1/2" 20-1 3 p _ - - - - 3
4. THE ACTIVE LEAF OF PAIRS OF EXTERIOR. SWING DOORS SHALL HAVE 3.0 30-2 1/2" #10 HWH 13 14 6
SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING DOORS. THE RANGE # 3/4" 50-2 12.0
INACTIVE LEAF SHALL HAVE MULTIPLIED POINTS OF LOCKS WITH 5/8" 1 L 15 16H lk
MIN. THROW BOLTS WITH INSERTS.
3:0 30-2 1/2" #10 yyyH 17 18 DRYER #10 1/2" , 30-2 5p 31 31
5. JAMBS OF ALL EXTERIOR OFFSET TYPE IN SWING DOORS SHALL BE , SD
RABBETED, OR OF SIMILAR FABRICATION, TO PREVENT DEFEATING THE 19 20
PURPOSE OF THE STRIKE AND THE INTEGRITY OF THE LOCKS AND EXIST. 6 X 12
LATCHES. 5.7 30-2 1/2" #10 A/C AH 21 22 1 A/C COMP #10 1/2" 30-2 3.5 WOOD BEAM 32 I
0
6. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE. NONREMOVABLE 23 24 '
PINS AND NON-EXPOSED SCREWS. 1.5 20-1 , 1/2" #12 KITCHEN GFI 25 ' 26 DISH WAHER #12 1/2" 20-1 1.5 _
7. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN 1.5 20-1 1/2" #12 REF. 27 28 BATH/UTILITY GFI #12 1/2" 20-1 1,5
NATIONAL STANDARDS INSTITUTE'S STANDARD 297.1. 1.5 15-111/2- #12 REF. 29 30 LITES & RECEP. #14 1/2" 15-1 1.0
1.0 15-1 1/2" 14 E l� A-I
8, VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40 OF / # LITES & RECEP. 31 32 4 ' I 1.0
32
-' THE INSIDE LOCKING ACTIVATING DEVICE OF LOOSE AND SWING DOORS SPACE 33 34 31
� Y1,,�,,� `
SHALL COMPLY WITH THE AMERICAN NATIONAL STANDARD
INSTITUE'S - STANDARD 297.1 35 36 31 931
9. WINDOWS SHALL BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL 37 38 W
CAN BE LIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION AND 39 40 GFI I
SO AS TO COMPLY WITH THE ARCHITECTURAL ALUMINUM MAGS
ASSOCIATION STANDARDS FOR FORCE ENTRY RESISTANCE, AAMA 1303.3 32 41 42
PROVIDE LOCKS AS PER SFBC 3603.2(A),(8)2(AA) AND (C) EXTERIOR
= s�
WINDOW SHALL BE LOCKED WITH DEVICE CAPABLE OF WITHSTANDING A 18
FORCE OF 150 LB. APPLIED IN AN OPERABLE DIRECTION.
5.7 FIRST 10 KVA 0 100% = 1 KVA
10. EXTERIOR WINDOW USED AS A MEANS OF ESCAPE SHALL ALSO COMPLY 15.6 KVA 3.5 +
WITH A DOOR SCOPE OR VISION PANELS. REMAINDER 0 40% = 9,2 KVA
A/C ® 100 = I: 145 AMPS `
;j
11. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE TOTAL = 34.8 KVA
OR VISION PANELS.
ELECTRICAL PLAN
1 /4
"-1 '
8. ELECTRICAL SYSTEM SHALL BE COMPLETELY GROUNDED AS REQUIRED BY THE 15. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND
ELECTRICAL GENERAL NOTES LATEST ADDITION OF THE N.E.C. TESTINGS.
9. ALL MATERIALS SHALL BE NEW AND SHALL BEAR UNDERWRITERS LABELS 16. THE ELECTRICAL INSTALATION SHALL MEET ALL STANDARD REQUIREMENTS
1. DO NOT SCALE ELECTRICAL DRAWINGS. REFER TO ARCHITECTURAL PLANS WHERE APPLICABLE. OF POWER AND TELEPHONE COMPANIES.
AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPTMENT AND CONFIRM 10. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR 17• FURNISH AND INSTALL 'DISCONNECT SWITCHES AND WIRING FOR AIR
WITH OWNER'S REPRESENTATIVE. IN A FIRST-CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL CONDITIONING SYSTEM AS PER MANUFACTURER RECOMMENDATIONS. CONTROLS
2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL BE FULLY OPERATIVE, AND ACCEPTED BY ENGINEER / ARCHITECT. ARE TO BE SUPPLIED BY AIR CONDITIONING CONTRACTOR AND CONNECTED " -'--�
:roject RENOVATION i v �
CODE AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES. 11. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFER- BY ELECTRICAL CONTRACTOR. P .
3. MINIMUM WIRE SIZE SHALL BE # 14 A.W,G., EXCLUDING CONTROL WIRING. ENCE WITH THE PROGRESS OF CONSTRUCTION. 18. ALL RACEWAYS UNDERGROUND SHALL BE A MINIMUM OF 3/4" CONDUIT.
UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE COPPER WITH THW. 12 CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE 19• ALL CIRCUIT BREAKERS TWO OR THREE POLE, TO BE COMMON TRIP. NO TIE
.
INSULATION. FROM DEFECTS FOR A PERIOD OF NOT LESS THAN 1 YEAR FROM DATE HANDLES, OR TANDEMS WILL BE ACCEPTED. `
4. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY OF ACCEPTANCE. ( ) FOR: MRS. & MR. �BEATY t.
WITH THREADED HUBS IN WET OR OR DAMP LOCATIONS AND SPECIAL 20 (C.L.) RATED� UFORS200 000 0 C DRAWING, SHALL BE CURRENT LIMITED FUSES \
13. CORRECTIONS OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL ( ) �`'< 6760 S.W. 68th TERRACE
ENCLOSURES FOR OTHER CLASSIFIED AREAS. \`\+
CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER 21. ROMEX IS AN APPROVED ALTERNATE WIRING METHOD IF APPROVED BY OWNER MIA,M I, FL. 33143
5. DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUTY, QUICK-MAKE, PHASE OF THE INSTALATION WHICH MAY HAVE BEEN DAMAGED THEREBY. !
QUICK-BREAK ENCLOSURES AS REQUIRED BY EXPOSURE. 14. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST ,1
6. MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC, WITH OVERLOAD RELAYS PUBLIC LIABILITY OF PROPERTY DAMAGED FOR THE DURATION OF WORK.
Cornmiss�on Number:
IN EACH HOT LEG.
7. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FORA Drawn bya� J:R.C.
COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY F ra
FOR EQUIPTMENT TO BE PLACED IN PROPER WORKING ORDER.
~ .`�•A.. . �;•• �'►,f Date 05/11 /00`
. f R
• e.,� u'
Sheets of
�.
L
A - 4 / of 5