00-0529-028 • I
j AA 0000080 _
-_Su-it2 100
6401 SW 87th Ave.
----- - kl,a;ni, Florida, 33173
(305) 271 - 1000
William Friedman, R.A. >A
ELECTRICAL RISER DIAGRAM ,; E _ AR 0002115
/ 3 STRIP
� D
W. BfI� I LIGHTS
SINK
3 26 GFI E
II
O.H. ELEC. SERVICE 14,16 E
3-3/0 THW IN 2 C. 01 El E
E E RANGE pl
200 AMP DISC. 200 AMP. PANEL 42 CB PANEL 27 29 GII 25
XIST.
REF. REF. ANEL PANTRY
ELECT. METER 3-3/0 THW CU. IN 2,. COND.-
1 #4 THW. COPPER IN 3/4" Ow
CONDUIT TO COLD WATER LINE
AND SLAB REBAR Q�
AND (2) 5/8 COPPER .CLAD �
STEEL RODS DRIVEN INTO THE
MIN. GROUND 10' MIN. DISTANCE
BETWEEN RODS SHALL BE NOT
a
LESS THAN 6'.
TABLE GFI SINK 2 H
28
V)
SD 13.15 •
TYPE ITE EQ EXISTING MAIN BUS . 225
SERVICE :� 240V-1 -3W NEUTRAL FULL
MOUNTING SURFAC PANEL MAINS MOO (225) O - - - +E_� Li
SECURITY AND FORCED ENTRY PREVENTION: POLES 42 A.I,C. 21,23
i VP
DEM NO. DEM TRIP ON WIRE REMARKS CKT. ICKT. REMARKS WIRE CON- TRIP NO. DEM DEM
1. PROVIDE INTRUSION AND BURGLARY SECURITY DEVICES AS SET FORTH K.V.A. K.V.A. POLE DUIT NO. NO. DUIT POLE K.V.A. K.V.A. 30
IN CHAPTER 36 OF THE SOUTH FLORIDA BUILDING CODE. C I
#12 1/2 28 C:
3.0 1.0 15-1 1/2- #14 STRIP LIGHTS 1 2 WASHER " 20-1 1.5
2. ALL LOCKS ON INTERIOR DOORS SHALL BE CAPABLE OF RESISTING A 1,5 20-1 1/2- #12 KITCHEN GFI 3 4 DINING GFI #12 1/2" 20-1 1,5 30
FORCE OF 300 LB. APPLIED IN ANY MOVEABLE DIRECTION AND IN
ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN THE SOUTH 1.0 15-1 1/2" #14 LITES & RECEP. 5 6 LITES & RECEP. #14 11/2" 15-1 1.5
FLORIDA BUILDING CODE. - - - - 32
3. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY 1.0 15-1 1/2" #14 LITES & RECEP. 7 8 LITES & RECEP. #14 1/2" 15-1 1.5
OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6000 POSSIBLE 1.0 15-1 1/2" #14 LITES & RECEP. 9 10 LITES & RECEP. #14 1/2" 15-1 1.5 301- 1 30
KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH _ - - - _
HARDENED BOLT INSERTS. 1.0 15-1 1/2" #14 LITES & RECEP. 11 1 12 POOL PUMP #12 1/2" 20-1 3.0
4. THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL HAVE 3.0 30-2 1/2" #10 HWH 13 14 RANGE #6 3/4" 50-2 12.0
SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING DOORS. THE _f U
INACTIVE LEAF SHALL HAVE MULTIPLIED POINTS OF LOCKS WITH 5/8" 15 16
MIN. THROW BOLTS WITH INSERTS. 3.0 30-2 1/2" #10 HWH 17 18 DRYER #10 1/2" 30-2 5,0 SD 31 31
5. JAMBS OF ALL EXTERIOR OFFSET TYPE IN SWING DOORS SHALL BE
RABBETED, OR OF SIMILAR FABRICATION, TO PREVENT DEFEATING THE I 19 20 EXIST. 6 X 12
PURPOSE OF THE STRIKE AND THE INTEGRITY OF THE LOCKS AND 5 7 30-2 1/2" #10 A/C AH 21 22 A/C COMP #10 1/2" 30-2 3,5 - - - WOOD BEAM - - 32
LATCHES. - -
23 24 J _
6. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NONREMOVABLE 1.5 20-1 1/2" #12 KITCHEN GFI 25 26 DISH WAHER #12 1/2" 20x-1 1.5
PINS AND NON-EXPOSED SCREWS.
7. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN 1.5 20-111/2" #12 REF. 27 28 BATH/UTILITY GFI #12 11/2" 20-1 1.5
NATIONAL STANDARDS INSTITUTE'S STANDARD 297.1. 1.5 15-1 1/2" #12 REF. 29 30 LITES & RECEP. #14 1/2" 15-1 1.0
8, VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40 OF 1.0 15-1 1/2" #14 LITES & RECEP. 31 32 LITES & RECEP. #14 1/2" 15-1 1,0 32 31
THE INSIDE LOCKING ACTIVATING DEVICE OF LOOSE AND SWING DOORS SPACE 33 34 SPACE 31 31
SHALL COMPLY WITH THE AMERICAN NATIONAL STANDARD
INSTITUE'S - STANDARD 297.1 35 36 P
9. WINDOWS SHALL BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL 37 38
_ CAN BE LIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION AND 39 40 GFI GFI
SO AS TO COMPLY WITH THE ARCHITECTURAL ALUMINUM MAGS L 32 32
ASSOCIATION STANDARDS FOR FORCE ENTRY RESISTANCE, AAMA 1303.3 41 42
PROVIDE LOCKS AS PER SFBC 3603.2(A),(8)2(AA) AND (C) EXTERIOR
WINDOW SHALL BE LOCKED WITH DEVICE CAPABLE OF WITHSTANDING A 18 31
FORCE OF 150 LB. APPLIED IN AN OPERABLE DIRECTION. p
10. EXTERIOR WINDOW USED AS A MEANS OF ESCAPE SHALL ALSO COMPLY 5.7 FIRST D 0 4 100 15.6 KVA 3.5
WITH A DOOR SCOPE OR VISION PANELS. REMAINDER ® 40- - 9.2 KVA
A/C ® 100% - 1: 145 AMPS
11. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE TOTAL = 34.8 KVA
OR VISION PANELS.
ELECTRICAL PLAN
1/4"=1
'
8. ELECTRICAL SYSTEM SHALL BE COMPLETELY GROUNDED AS REQUIRED BY THE 15. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND
ELECTRICAL GENERAL NOTES LATEST ADDITION OF THE N.E.C. TESTINGS•
9. ALL MATERIALS SHALL BE NEW AND SHALL BEAR UNDERWRITERS LABELS 16. THE ELECTRICAL INSTALATION SHALL MEET ALL STANDARD REQUIREMENTS
1. DO NOT SCALE ELECTRICAL DRAWINGS. REFER TO ARCHITECTURAL PLANS WHERE APPLICABLE. OF POWER AND TELEPHONE COMPANIES.
AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPTMENT AND CONFIRM 10• ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR 17• FURNISH AND INSTALL DISCONNECT SWITCHES AND WIRING FOR AIR
WITH OWNER'S REPRESENTATIVE. IN A FIRST-CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL CONDITIONING SYSTEM AS PER MANUFACTURER RECOMMENDATIONS. CONTROLS
2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL BE FULLY OPERATIVE, AND ACCEPTED BY ENGINEER / ARCHITECT. ARE TO BE SUPPLIED BY AIR CONDITIONING CONTRACTOR AND CONNECTED Project: RENOVATION
BY ELECTRICAL CONTRACTOR.
CODE AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES.' 11. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFER 18. ALL RACEWAYS UNDERGROUND SHALL BE A MINIMUM OF 3/4" CONDUIT.
3. MINIMUM WIRE SIZE SHALL BE # 14 A.W,G., EXCLUDING CONTROL WIRING. ENCE WITH THE PROGRESS OF CONSTRUCTION.
UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE COPPER WITH THW 12. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE 19: ALL CIRCUIT BREAKERS TWO OR THREE POLE, TO BE COMMON TRIP. NO TIE FOR: MRS. & MR. . BEATY
INSULATION. FROM DEFECTS FOR A PERIOD OF NOT LESS THAN (1) YEAR FROM DATE HANDLES, OR TANDEMS WILL BE ACCEPTED.
4. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY OF ACCEPTANCE. 20. ALL FUSES, UNLESS NOTED ON DRAWING, SHALL BE CURRENT LIMITED FUSES 6760 S.W. 68th TERRACE
WITH THREADED HUBS IN WET OR OR DAMP LOCATIONS AND SPECIAL 13. CORRECTIONS OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL (C.L.) RATED FOR 200,000 A.I.C. MIAMI, FL. 33143
ENCLOSURES FOR OTHER CLASSIFIED AREAS. CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER 21. ROMEX IS AN APPROVED ALTERNATE WIRING METHOD IF APPROVED BY OWNER
5. DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUTY, QUICK-MAKE, PHASE OF THE INSTALATION WHICH MAY HAVE BEEN DAMAGED THEREBY.
QUICK-BREAK ENCLOSURES AS REQUIRED BY EXPOSURE. 14. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST COmmISSIOn Number:
6. MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC, WITH OVERLOAD RELAYS PUBLIC LIABILITY OF PROPERTY DAMAGED FOR THE DURATION OF WORK.
IN EACH HOT LEG. ff
7. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A •• ,• �� Drawn by: J.R.C.
O
COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY ` .w • �y •••
FOR EQUIPTMENT TO BE PLACED IN PROPER WORKING ORDER.
Date: 06/26/00
�< ` •� �� Sheet of
� '
A - of 5