00-0529-027 AA 0000080 =
� ui;e; 100
r 6401 SW 87th Ave. .
1__ Miami, Florida, 331-73�.—•
(305) 271 - 1000
William Friedman, R.A. s�
AR 0002115 p�
EXISTING
PANTRY D.W. SINK fj
°I°
RANGE I
6' WOOD FENCE O
1221 1221
PANTRY
STUCCO REF. REF. !%-
— — — — — — — — — — — — — — — — — — — — — — — — — — to
OW 6/
a
NORTH ELEVATION
Lf
1/4"=1 ' EXISTING
RESIDENCE F
r — ,
DRYER
NEW TABLE SINK � HyH.� VENT
.
RELOCATE EXIST.
V ,!
A/C UNIT
AIR HANDLER
EXISTING --� — — — —
do
C I CF 6
6X
SAE 140
FRWTT7 SS , , I 4"�1S tom, •
EXISTING 0 8X8
CONNECT TO J
EXIST. A/C CFM
- "_ - - -,J, - - I
-- -- -- 1nTnT11r11nTnTnr,1r11nTn CF i50 6„,1 CF 8X8
Clio 150
EXIST. 6 x 12
WEST ELE VATION WOOD BEAM
— �
14X14X
AIR CONDITIONING SYSTEM — GENERAL NOTES
I,
1. DUCTWORK SHALL BE 1 1/2- THICK. 3 POUNDS PER CUBIC FOOT 5. A/C SYSTEM SHALL HAVE DISPOSABLE AIR FILTERS LOCATED AS
DENSITY FIBERGLASS WITH VAPOR BARRIERS. UNLESS OTHERWISE REQUIRED FOR EASY ACCESSIBILITY.
SPECIFIED. DUCKWORK SHALL BE FABRICATED AND INSTALLED IN ' s
ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS & ACCORDING 6. A/C SYSTEM SHALL BE CONTROLLED BY A THERMOSTAT, MOUNT
TO "ASHRAE" & "SMACNA" STANDARDS. THERMOSTAT 5'-0" ABOVE FINISHED FLOOR. U.O.N. I L i It • ; • I I ( �'�
`i
DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND TO INSIDE 7. ALL GRILLES & DIFFUSERS TO BE ALUMINUM CONSTRUCTION. DIFFUSERS
DIMENSIONS WIDTH X HEIGHT. DUCT SYSTEM SHALL COMPLY W/ SHALL HAVE HIDDEN OPPOSED BLADE DAMPERS. PROVIDE GASKETS p
"NFPA" STD. N0. 90A AND/OR 908. DUCTWORK AND COMPONENTS ON ALL GRILLES & DIFFUSERS. TITUS OR AIREGUIDE FINISHED COLOR AC f LA
SHALL BE CLASS 1 MATERIALS IN ACCORDANCE WITH U.L. 181 BY ARCHITECT.
TESTS. PROVIDE FIRE DAMPERS WHEN CROSSING F. RATED WALLS
OR CEILING. 8. UNDERCUT DOORS. 1" A.F.F. AS INDICATED.
2. COORDINATE LOCATIONS. SIZE & OPENINGS W/OTHER TRADES ON THE 9, ALL REFRIGERANT PIPING SHALL BE COPPER—HARD—DRAWN TYPE L-
JOB. A/C CONTRACTORS. SHALL PROVIDE THE COMPLETE DUCT SYSTEM ACR TYPE. DEHYDRATED & SEALED. ALL FITTINGS SHALL BE WROUGHT
W/ TURNING VANES AT ALL ELBOWS. SPLITTERS & DAMPERS. AS COPPER ALL JIONTS SHALL BE MADE WITH HIGH TEMPERATURE BRAZING
REQUIRED. ALLOY OF NOT LESS THAN 5% SILVER. PIPING INSULATION NOT LESS
THAN 3/4" THICK "ARMAFLEX". LIQUID & SUCTION LINES SHALL BE
3. DIFFUSERS SHALL BE SELECTED. LOCATED AND BALANCED IN ORDER SIZED ACCORDING TO EQUIPMENT MANUFACTURER'S RECOMMENDATIONS
THAT THEY DELIVER THE REQUIRED CFM TO THE ENTIRE ROOM EVENLY FOR EQUIVALENT LENGTH OF PIPING RUN FOR CONNECTED TONNAGE.
& DRAFT FREE TO MAINTAIN THE FOLLOWING DESIGN CONDITIONS: ALL PIPING ACCESSORIES SHALL BE CONSTRUCTED AS SUGGESTED BY
EQUIPMENT MANUFACTURER. ALL PIPING SHALL BE EVACUATED PER Project: RENOVATION
INSIDE OUTSIDE RELATIVE HUMIDITY GOOD PIPING PRACTICE BEFORE STAR—UP. PROVIDE FILTER/DRYER
COOLING — 76DB 91 DB — 79WB 509 TO 60% AND SIGHT CLASS ON LIQUID LINE. t r
FOR::` MRS. & MR. BEA711
HEATING — 72DB 45D8
R 6760 S.W. 68th TE RAGE,,
4. ALL FAN UNITS, MOTORS, COMPRESSORS, ETC. SHALL BE ISOLATED MIAMI, FL. 33143 ' ,
AS REQUIRED TO OPERATE QUIETLY SO THAT NO OBJECTIONABLE SOUND y``
WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY, I Com'�rlissio f�lumber•
MOTOR HUM, VIBRATION, OR MECHANICAL MOVEMENT.
Draw , by: "'J.R:C. `� 1
E.• f 1 C Date: 05/11 /00
All
r •
o ; Sheet =of
o f 5