Loading...
00-0529-017 -_ AA C000080 s Suite 100 6401 SW 87th Ave. -Miami, Florida, 33173 ELECTRICAL RISER DIAGRAM � � - _ �---;(305) 271 - 1000 William Friedman, R.A. AR 0002115 F f� O.H. ELEC. SERVICE 2-3/0 THW IN 2" C. 200 AMP DISC.----,, 200 AMP. PANEL 42 CB PANEL 8 • M ELECT. METER 3-3/0 THW CU. IN 2" COND. 3E _---_� �-- ' 3 STRIP LIGHTS ---�-�.W. . 1 #4 THW. COPPER IN 3/4 SINK- r CONDUIT TO COLD WATER LINE s 26 GFI E ' AND SLAB REBAR 14,16 AND (2) 5/8 COPPER CLAD (� =Q" STEEL RODS DRIVEN INTO THE E E "�i�E MIN. GROUND 10' MIN. DISTANCE RANGE V BETWEEN RODS SHALL BE NOT GFI 5 LESS THAN 6'. 29 29 ' _---_ -_ _- EXIS PAN REF REF. OW SECURITY AND FORCED ENTRY PREVENTION : --- --------- ------- - ------ ---------- ------- _ TYPE ITE EQ MAIN BUS : 125 1 . PROVIDE INTRUSION AND BURGLARY SECURITY DEVICES AS SET FORTH SERVICE 240V-1 3W A NEUTRAL FULL j MOUNTING SURFACE PANEL MAINS MCO (125) l IN CHAPTER 36 OF THE SOUTH FLORIDA BUILDING CODE. POLES : 42 A.I.C. 10K 2. ALL LOCKS ON INTERIOR DOORS SHALL BE CAPABLE OF RESISTING A DEM NO. DEM ;TRIP CON-J WIRE REMARKS CKT. �CKT., REMARKS WIRE CON-:TRIP N0. DEMi OEM K.V.A. K.V.A. POLE DUIT INO. ! :NO. _ I DUIT POLE i K.V.A. K.V.A. I - I -- 1 --- WASHER - 12 1/2" ! 20-1 FORCE OF 300 LB. APPLIED IN ANY MOVEABLE DIRECTION AND IN -_ � - ±----,----. ---- ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN THE SOUTH 1.0 15 1 ; 1/2 #14 STRIP LIGHTS -- _ - FLORIDA BUILDING CODE. 1.5 20-1 ', 1/2" #12 KITCHEN GFI 3 4 i DINING GFI #12 1/2" 120-1' 1.5 _ r- - --- -�---- - - - --- ---- 1 - 3. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY ,, i 5 ! 6 ' #14 ~ 1 2" 15-1 1.5 �SINK� 2 H H - OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6000 POSSIBLE ' 1.0 15-1 . 1/2 #14 f LITES & RECEPT. i LITES & RECEP. i / I _-! NEW 'TABLE _ �' ------ i 1.0 15-1 ' 1/2" I #14 1 LITES & RECEPT. 7 8 LITES & RECEP. #14 1/2" 15-1' 1.5 �` 0 KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH 1 -_ � _-_- _- _--- _ -: NEW --- j HARDENED BOLT INSERTS. 1.0 15-1 1/2" #14 i LITES & RECEPT. 9 ! ! 10 ' LITES & RECEP_ #14 1/2" 15-1 '; 1.5 _ SD 13,15 4. THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL HAVE 1.0 , 15-111/2" : #14 j LITES & RECEPT. 11 12 POOL PUMP - #12 1/2" j 20-1 3,0 t SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING DOORS. THE 3 0 , 30-2 1/2 #10 ! HWH 13 14 RANGE #6 3/4 1 50-2; 12.0 INACTIVE LEAF SHALL HAVE MULTIPLIED POINTS OF LOCKS WITH 5/8 -- ------ - ---+--- -- -- -- --- - ° 15 16 MIN. THROW BOLTS WITH INSERTS. - 3.0 ; 30-2 1/2" ! #10 HWH 17 18 DRYER -_- #10 1 1/2" 130-2 5.0 5. JAMBS OF ALL EXTERIOR OFFSET TYPE IN SWING DOORS SHALL BE � �- I I 21,23 19 20 , . RABBETED, OR OF SIMILAR FABRICATION, TO PREVENT DEFEATING THE -- -- - -- - - ---- --?- - - --- -?-- - �- 30 PURPOSE OF THE STRIKE AND THE INTEGRITY OF THE LOCKS AND 5.7 30-2' 1/2`#10 1 A/C AH 21 122 , A/C COMP - #10 1/2" 30-2+ - ! 3.5 - , 30 - LATCHES. -- -�--- i ! ---- �4�-- T � �/� � i ' 30 -- i 1.5 ! 20-1 ! 1/2 j #12 KITCHEN GFI 1 25 1 126 DISH WASHER- _ #�12 1/2 20-11 1.5 6. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NONREMOVABLE 1.5 20-1 1/2' #12 REF. 27 28 BATH/UTILIII' GFI #12 1/2" 20-1 ! - - - PINS AND NON-EXPOSED SCREWS. � - �� 8 „�-�- 1.5 20-1 1/2" 12 REF. 29 30 LITES & RECEP. #14 j 1/2 15-1 ' 1.0 ---- - ---; -1- I r 1.0 1 15-1 1/2" #14 ' LITES & RECEP. 31 321' & RECEP. #14 1/2 15-1 1 0 7. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN / ; - i --- -- -' -- -� NATIONAL STANDARDS INSTITUTE'S STANDARD 297.1 . 1.5 20-1 1/2 #12 SMALL APPLIANCES 33 34 SPACE _ --- ! } - 30 � - - - - - - 35 1 36 - - --- -- + - --r --- I 30 30� r --- - -- _ I SPACE 8. VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40 OF 37 38 ' i THE INSIDE LOCKING ACTIVATING DEVICE OF LOOSE AND SWING DOORS -- ------ - --- -- - - ; -r;- ------ -�-�- -`� SHALL COMPLY WITH THE AMERICAN NATIONAL STANDARD - 3s ; 40 - INSTITUE'S - STANDARD 297.1 -- - ' - -i------ --' 31 31 ° --- - ------ 41 42 i _..- I EXIST. 6 X 12 19.5 i-31 - _ _ _ WOOD BEAM _ _ _ _ SD 9. WINDOWS SHALL BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL --- ------- -! $ CAN BE LIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION AND 22.5 FIRST 10 KVA ® 100% 100.3 KVA 3.5_16. SO AS TO COMPLY WITH THE ARCHITECTURAL ALUMINUM MAGS REMAINDER ® 40% - 15.L6 KVA ASSOCIATION STANDARDS FOR FORCE ENTRY RESISTANCE, AAMA 1303.3 A/c ® 100% I: 147.5 AMPS PROVIDE LOCKS AS PER SFBC 3603.2(A),(8)2(AA) AND (C) EXTERIOR TOTAL = 35.4 KVA 8 WINDOW SHALL BE LOCKED WITH DEVICE CAPABLE OF WITHSTANDING A _ _ _ -- I 32 FORCE OF 150 LB. APPLIED IN AN OPERABLE DIRECTION. --- --- --- _ - C9F0 31 10. EXTERIOR WINDOW USED AS A MEANS OF ESCAPE SHALL ALSO COMPLY WITH A DOOR SCOPE OR VISION PANELS. Wp 11 . FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE 31 OR VISION PANELS. ELECTRICAL ELECTRICAL SYSTEM SHALL BE COMPLETELY GROUNDED AS REQUIRED BY THE 15 CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND ELECTRICAL GENERAL NOTES LATEST ADDITION OF THE N.E.C. 9. ALL MATERIALS SHALL BE NEW AND SHALL BEAR UNDERWRITERS LABELS 16. THE ELECTRICAL INSTALATION SHALL MEET ALL STANDARD REQUIREMENTS 32 1. DO NOT SCALE ELECTRICAL DRAWINGS. REFER TO ARCHITECTURAL PLANS WHERE APPLICABLE. OF POWER AND TELEPHONE COMPANIES. AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPTMENT AND CONFIRM 17. FURNISH AND" INSTALL DISCONNECT SWITCHES AND WIRING FOR AIR WITH OWNER'S REPRESENTATIVE. 10. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR CONDITIONING SYSTEM AS PER MANUFACTURER RECOMMENDATIONS. CONTROLS IN A FIRST-CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL ARE TO BE SUPPLIED BY AIR CONDITIONING CONTRACTOR AND CONNECTED GFI 321 Project: RENOVATION BE FULLY OPERATIVE, AND ACCEPTED BY ENGINEER / ARCHITECT. 32 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL BY ELECTRICAL CONTRACTOR. 01 � _� ° CODE AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES. 11. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFER- 18. ALL RACEWAYS UNDERGROUND SHALL BE A MINIMUM OF 3/4" CONDUIT. 3. MINIMUM WIRE SIZE SHALL BE # 14 A.W.G., EXCLUDING CONTROL WIRING. ENCE WITH THE PROGRESS OF CONSTRUCTION. UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE COPPER WITH THW 12. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE 19. ALL CIRCUIT BREAKERS TWO OR THREE POLE, TO BE COMMON TRIP. NO TIE FOR: MRS. & MR. BEA INSULATION. FROM DEFECTS FOR A PERIOD OF NOT LESS THAN (1) YEAR FROM DATE HANDLES, OR TANDEMS WILL BE ACCEPTED. 4. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY OF ACCEPTANCE. 20. ALL FUSES, UNLESS NOTED ON DRAWING, SHALL BE CURRENT LIMITED FUSES ELECTRICAL PLAN 676o S.W. 68th TERRACE WITH THREADED HUBS IN WET OR OR DAMP LOCATIONS AND SPECIAL 13. CORRECTIONS OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL (C.L.) RATED FOR 200,000 A.I.C. MIAMI, FL. 33143 ENCLOSURES FOR OTHER CLASSIFIED AREAS. CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER 21. ROMEX IS AN APPROVED ALTERNATE WIRING METHOD IF APPROVED BY OWNER / 5. DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUTY, QUICK-MAKE, PHASE OF THE INSTALATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 1 4 =1 Commission Number: QUICK-BREAK ENCLOSURES AS REQUIRED BY EXPOSURE. 14. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST 6. MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC, WITH OVERLOAD RELAYS PUBLIC LIABILITY OF PROPERTY DAMAGED FOR THE DURATION OF WORK. .... ... .. .. IN EACH HOT LEG. -,.._ .. _ -�� .__ ..._-•-,::p. � ..,.�-,.::,� .. .. CC ` � p �4��`�y Drawn by: ....• ..-. _- , 7. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY Date: 10/06/00 FOR EQUIPTMENT TO BE PLACED IN PROPER WORKING ORDER. g` Sheet of A - 4 of 5