00-0529-011
I� AA 0000080 a f U Suite 100 -- -- 6401 SW 37th Ave. ELECTR:IC,4L_ RI SE R DIAGRAM 305''> 271 - 10003173 I c William Friedman, R.A. AR 0002115 O.H. ELEC. SERVICE 2-3/0 THW IN 2" C. 200 AMP DISC. 200 AMP. PANEL 42 CB PANEL - ELECT. METER 3-3/0 THW CU. IN 2" COND. 3 E I------------ r 3 STRIP PANTRY - - { - - �- GFf LIGHTS D.W. I :::_ .--•- -------- 1 #4 THW. COPPER IN 3/4" CONDUIT TO COLD WATER LINE 3 26 SINK ; GFI AND SLAB REBAR E AND (2) 5/8" COPPER CLAD 14,16 �.-6_-0 STEEL RODS DRIVEN INTO THE E E MIN. GROUND 10' MIN. DISTANCE RANGE; BETWEEN RODS SHALL BE NOT LESS THAN 6'. 29 29 GFI 5 � -- --- --_ , EXIS -- -- ___ PAN REF REF. 3 - - 0 SECURITY AND FORCED ENTRY PREVENTION : - _ _- --_----- - --- - -- -_----- ----- ------ ---------- ---- - ----- - - - __ ---_- - - _ sal ow - 1 . PROVIDE INTRUSION AND BURGLARY SECURITY DEVICES AS SET FORTH SERVICE 240V 41 -3W MAIN Bus : 125 -- -- _ NEUTRAL FULL IN CHAPTER 36 OF THE SOUTH FLORIDA BUILDING CODE. MOUNTING SURFAC PANEL MAINS MCO (125) POLES 42 10K IC 2. ALL LOCKS ON INTERIOR DOORS SHALL BE CAPABLE OF RESISTING A DEM NO. DEM TRIP CON-11 WIRE ' REMARKS CKT. CKT., REMARKS WIRE 'CON-TRIP :NO. DEM DEM .t FORCE OF 300 LB. APPLIED. IN ANY MOVEABLE DIRECTION AND IN K.V.A. K.V.A. POLE DUIT NO 4 NO. - DUIT POLE 'K.V.A. K.V.A. ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN THE SOUTH 1.0 15-1 1/2" #14 STRIP LIGHTS 1 2 WASHER #12 1/2" 20-1 1.5 FLORIDA BUILDING CODE. -- - - -- -- ---- - - - - - --- --- -- -- -------- - -T __ .- - - 1 5 20 1 1/2" #12 1 KITCHEN GFI 3 4 DINING GFI _ #12 1/2" i1 20-1 1.5 - - -- _ - . -- - ----- ---- ------ ---- _ --- ------ ---- __------_-- - -- ---- --.- --- � ---_' 3. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY r 3 OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6000 POSSIBLE 1.0 15-1 1/2" #14 LITES_& RECEPT. 5 6 , LITES & RECEP. #14 1/2" 15-1 , 1,5 3 "JHH) ------- -- - --- --- _ _. -- -- i- NEW TABLE 'SINK 2 - - -- 1/2" #14 LITES &- - 8;.-_._LITES & RECEP-- 1 #14- .--.1- 2" 15-1 1.5 , - --- NEW - - -HARDENEDGBOL�RINSERTS.LOCKING AUXILIARY SINGLE DEAD BOLT WITH 1 0 15_1 1/2" #14 ; LITES & RECEPT. Y 9 10 ' 14 1/ "? 15-1 1 1 12 , POOL PUMP 12 1/?_ 1.5 - -- 2" --- -- ---- -- ----- LITES & RECEP. __._# 13,15 4. THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL HAVE 1.0 15-1 1/2" #14 LITES & RECEPT. # 1/2" 20-1 3,0 SD SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING DOORS. THE - - -- - ' -- INACTIVE LEAF SHALL HAVE MULTIPLIED POINTS OF LOCKS WITH 5/8" 3.0 30-2 1/2" #10 HWH 13 14 RANGE _ ,�6 t3/4' 50-2 - 120 - n�__ S-i'i- cc - - --- �v1�N:THRE1�. BO�T.� vvITH INP.TS-:-- ---- --__._..._ . _ ____-- _----_ _ ....___ _ 15 � ' 16 - - - a - 3.0 #1 - HWH 17 18 --- 10 1 2" ,- 30-2 1/2" , DRYER # / 30-2 5.0 r 5. JAMBS OF ALL EXTERIOR OFFSET TYPE IN SWING DOORS SHALL BE - --- -- - - - - - ------ - -- - -- - - - --- ----- - -- -- -- - - - - - -" i 19 20 21 23 LL RABBETED, OR OF SIMILAR FABRICATION, TO PREVENT DEFEATING THE - - - --- - - -- - -- ----- - - - ;-- - -._ _---- -- ----- -- ± - -- -- - -- -- ---- - PURPOSE OF THE STRIKE AND THE INTEGRITY OF THE LOCKS AND LATCHES. A/C COMP ! #10 1/2" 30-2 3.5 ----- 30 30 5.7 30-2 1/2" 10 21 22 - --- 23 24 / 30 m --- • DISH WASHER #12 1/2 20-1 - KITCHEN GFI 25 26 o 1.5 20-1 1/2" #12 / 6. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NONREMOVABLE 1.5 20-1 1/2" #12 REF. 27 28 BATH UTILITY GFI #12 1/2 20-1 __ _. _ _ __ ,� . PINS AND NON-EXPOSED SCREWS. _ --- � -- ___ -- --- -------- ----- ---- -- ----- t--------- - 1/2" 115-1 -� LITES & RECEP #14 - 1.0 15-1 1/2" #14 LITES & RECEP. 31 32 - - - - - -- - 1.5 20-1 1 2 12 REF. 29 30 7. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN _ /2 1.0 - - -- _ _-- -- _. -- - - -- - __- - --------------_ ! _ -- -I---LITES-& RECEP. #14 1 15-1 NATIONAL STANDARDS INSTITUTES STANDARD 297. 1 . 1.5 20-1 1/2" #12 SMALL APPLIANCES 33 34 ; SPACE -- - - - -- 30 _ � 3, SPACE 35 36 ' - -- 30 0 8. VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40 OF -_. __-_-_-- - ----.- -----_-----____-- --_____-- __ _-- . -- THE INSIDE LOCKING ACTIVATING DEVICE OF LOOSE AND SWING DOORS - - - ---- -- - - -- ------- -- -- -- --- -- -- - ----------- ----- -- - - --- - - - _ =--_--- __-__ FI 37 38 ' SHALL COMPLY WITH THE AMERICAN, NATIONAL STANDARD _39 40 _ INS i UE S - STANDARD 297.1 - 41 - - -- --- --- ------- - 42 , - - - - -- -- - EXIST. 6 X 12 31 31 19.5 31 --- WOOD BEAM so 9• WINDOWS SHALL BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL - -- -- - - - - - - - - - - - _ - CAN BE LIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION AND 22.5 FIRST 10 KVA © 100% 10.0 KVA ' 3.5' ❑ „ - - REMAINDER ® 40% = 16.2 KVA = --- -- SO AS TO COMPLY WITH THE ARCHITECTURAL ALUMINUM MACS A/C � 100% = 15.6 KVA I: 147.5 AMPS ASSOCIATION STANDARDS FOR FORCE ENTRY RESISTANCE, AAMA 1303.3 PROVIDE LOCKS AS PER SFBC 3603.2(A),(B)2(AA) AND (C) EXTERIOR TOTAL = 35.4 KVA WINDOW SHALL BE LOCKED WITH DEVICE CAPABLE OF WITHSTANDING A --- --- ---- -_. --------- --- -- ---- --- - - - ----- - ------ -- ---- - -- - - - - - -- -- 32 ; a FORCE OF 150 LB. APPLIED IN AN OPERABLE DIRECTION. - -- ----- - 10. EXTERIOR WINDOW USED AS A MEANS OF ESCAPE SHALL ALSO COMPLY WITH A DOOR SCOPE OR VISION PANELS. ' 31 GFI WP 11 . FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE OR VISION PANELS. ; 31 ]ELECTRICAL GENERAL NOTES 8. ELECTRICAL SYSTEM SHALL BE COMPLETELY GROUNDED AS REQUIRED BY THE 15. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND LATEST ADDITION OF THE N.E.C. 9. ALL MATERIALS SHALL BE NEW AND SHALL BEAR UNDERWRITERS LABELS 16. THE ELECTRICAL INSTALATION SHALL MEET ALL STANDARD REQUIREMENTS 32 I /� 1. DO NOT SCALE ELECTRICAL DRAWINGS. REFER TO ARCHITECTURAL PLANS WHERE APPLICABLE. OF POWER AND TELEPHONE COMPANIES. AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPTMENT AND CONFIRM 10. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR 17. FURNISH AND INSTALL DISCONNECT SWITCHES,AND WIRING FOR AIR WITH OWNER'S REPRESENTATIVE. IN A FIRST-CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL CONDITIONING SYSTEM AS PER MANUFACTURER RECOMMENDATIONS. CONTROLS 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL BE FULLY OPERATIVE, AND ACCEPTED BY ENGINEER / ARCHITECT. ARE TO SUPPLIED Y AIR CONDITIONING CONTRACTOR AND CONNECTED 1,a •c�, t' 3Z Project: RENOVATION CODE AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES. 32 Il �° 1 1. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFER- 3. MINIMUM WIRE SIZE SHALL BE # 14 A.W.G., EXCLUDING CONTROL WIRING. ENCE WITH THE PROGRESS OF CONSTRUCTION. 18. ALL RACEWAYS UNDERGROUND SHALL BE A MINIMUM OF 3/4" CONDUIT. UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE COPPER WITH THW 12. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE 19. ALL CIRCUIT BREAKERS TWO OR THREE POLE, TO BE COMMON TRIP. NO TIE FOR: MRS. & MR. BEATY INSULATION. FROM DEFECTS FOR A PERIOD OF NOT LESS THAN (1) YEAR FROM DATE HANDLES, OR TANDEMS WILL BE ACCEPTED. 4. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY OF ACCEPTANCE. 20. ALL FUSES, UNLESS NOTED ON DRAWING, SHALL BE CURRENT LIMITED FUSES ELECTRICAL PLAN 6760 S.W. 68th TERRACE WITH THREADED HUBS IN WET OR OR DAMP LOCATIONS AND SPECIAL 13. CORRECTIONS OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL (C.L.) RATED FOR 200,000 A.I.C. MIAMI, FL. 33143 ENCLOSURES FOR OTHER CLASSIFIED AREAS. CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER 21. ROMEX IS AN APPROVED ALTERNATE WIRING METHOD IF APPROVED BY OWNER 1 /4"- 1 ' 5. DISCONNECT SWITCHES SHALL BE N.P. RATED, HEAVY DUTY, QUICK-MAKE, PHASE OF THE INSTALATION WHICH MAY HAVE BEEN DAMAGED THEREBY. - QUICK-BREAK ENCLOSURES AS REQUIRED BY EXPOSURE. 14. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST Commission Number: 6. MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC, WITH OVERLOAD RELAYS PUBLIC LIABILITY OF PROPERTY DAMAGED FOR THE DURATION OF WORK. IN EACH HOT LEG. x...., .� Drawn b 7. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FORA r E ( 0 Y COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY FOR .EQUIPTMENT TO BE PLACED IN PROPER WORKING ORDER. `,•''.��.' • �'���' a"e Date: 10/06/00 .. Sheet of • r� A - 4 .c _ I