00-0529-009 AA C000080 $ U Suite 100 6401 SW 87th Ave. ELECTRICAL RISER 'D IAG RAM Miami, Florida, 33173 - --- (305) 271 - 1000 William Friedman, R.A. AR 0002115 O.H. ELEC. SERVICE 2-3/0 THW IN 2" C. 200 AMP DISC.-, 200 AMP. PANEL 42 CB PANEL M ELECT. METER 3-3/0 THW CU. IN 2" COND. E STRIP PANTRY I -GFf LIGHTS 1 #4 THW. COPPER IN 3/4" Y- ------ D.w ==-----_ -- _ CONDUIT TO COLD- WATER LINE a SINK GFI 26 AND SLAB REBAR E _ AND (2) 5/8" COPPER CLAD 14,16 MIN STEEL RODS DRIVEN INTO THE E E C " _ E • GROUND 10' MIN. DISTANCE RANGE -- BETWEEN RODS SHALL BE NOT J LESS THAN 6 . 29 29 cFl 5 REF REF. AN It SECURITY AND FORCED ENTRY PREVENTION :. - ------ ------ , ZOW 1 . PROVIDE INTRUSION AND BURGLARY SECURITY DEVICES AS SET FORTH SERVICE 240V-10-3W MAIN Bus : 125 -- NEUTRAL : FULL q ' IN CHAPTER 36 OF THE SOUTH FLORIDA BUILDING CODE. MOUNTING SURFACE PANEL A MAINS MCO (125) � a POLES 42 _ A.I.C. 0K 2. ALL LOCKS ON INTERIOR DOORS SHALL BE CAPABLE OF RESISTING A DEM NO. DEM TRIP CON- WIRE T T T - - --- -"- - - REMARKS CKT. iCKT.! REMARKS i WIRE CON- TRIP N0. DEM DEM - - FORCE OF 300 LB. APPLIED IN ANY MOVEABLE DIRECTION AND IN K.V.A. iK.V.A-. POLE .DUIT No. 1 ,NO ! DUIT POLE K.V.A. K.V.A. ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN THE SOUTH --- '-- -`- - - - ----------�---- ---- --- - 1.0 - 15-1 ` 1/2" #14 STRIP LIGHTS 1 2 WASHER #12 1/2" 20-1 . 1,5 FLORIDA BUILDING CODE. -- - _. -=-- 1.5 20-1 1/2" #12 KITCHEN GFI 3 4 DINING GFI #12 1/2" 20-1 1.5 3. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY - �)H O PERATED FROM THE EXTERIOR WITH A MINIMUM OF 6000 POSSIBLE Y t.o 15-t t/2" #14 LITES & RECEPT. 5 6 ' LITES & RECEP. #14 1/2" 15-1 1.5 NEW TABLE SINK 2 KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH - 1.0 15-1 1/2" #14 LITES & RECEPT. 7 ' 8 14 1 2" 15-1 1 5 '_ __ _� ---.LITES & RECEP. # /HARDENED BOLT INSERTS. � - - - NEW --- ..- LITES & RECEP. #14 1/2" 15-1 5 Li - _ 1 0 15-1 1�2' #14 LITES & RECEPT 19 10 -- - - ----- -- --- ------ �- -- -- • - -- 13,15 ' 4. THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL HAVE 1.0 15-1 1/2" # _ S & RECEPT 12* POOL PUMP ! #12 1/2" 20-1 3.0 SD SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING DOORS. THE - --- - - INACTIVE LEAF SHALL HAVE MULTIPLIED POINTS OF LOCKS WITH 5/8" 3 0 30-2 1 2" #10 H1�lH 13 14 RANGE #6 3/4" 50-2 12.0 - - - --- -, -- - • -- --- -- ---H ----- - - MIN. THROW BOLTS WITH INSERTS. 15 16 3.0 30-2 1/2" 10 #10 -- - - ---- ;' -- -- - -- - - I 5. JAMBS OF ALL EXTERIOR OFFSET TYPE IN SWING DOORS SHALL BE DRYER # 0 1/2- 30-2 / # HWH 17 � � 18 �� 1 5.0 I - --- - I ! -- RABBETED, OR OF _SIMILAR FABRICATION, TO PREVENT DEFEATING THE _ _ _ _ _ ?_1,23 / #10 A/C AH -29 220 ' A C COMP 10 '---- -- - _. ------- ' --r1- - - PURPOSE OF THE STRIKE AND THE INTEGRITY OF THE LOCKS AND 5.7 30-2 1/2" 30-2 -- � 30 LATCHES. - ---- -- --- / # 1/2 3.5 _ " - ---- 23 30 ------ - -- 24 C ----- -- - -- 1- - �- ° 1.5 20-111/2" #12 KITCHEN GFI 25 26 " 1.5 ---- -_ y _ _ DISH WASHER #12 1/2 , 20-1 6. HINGES ON EXTERIOR "OUT SWINGING DOORS SHALL HAVE NONREMOVABLE 1.5 -• 20-1 1 2' / #12 : REF. - --T27 r 28 BATH/UTILITY GFI #12 1/2 20-1-.. 1.5 I PINS AND NON-EXPOSED SCREWS. __- _-- _-- _ _-- - -- - a - -- -- - - _ #14 _ -- _ 30 f LITES & RECEP. 15-1 V - 1.0 __ - ---- --- 1.0 15-1 1 2 14 LITES & RECEP. 31 - j #14 I $ 1.5 1 2 12 REF. ----_ --_-_- 29 7. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN / # 32 / 1.0 ,_- 30_ ' '-- - - _. -_ __ ..- - ---• ------- ------- ---• ---------- ----------- LITES & RECEP � 1 2' 15-1 � NATIONAL STANDARDS INSTITUTE'S STANDARD 297. 1 . -- _ ti 1. 20-1 1 2 12 SMALL APPLIANCES ; 33 34 SPACE SPACE 35 36 -- 3 8. VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40 OF - -- - - ---- -, �---- f THE INSIDE LOCKING ACTIVATING DEVICE OF LOOSE AND SWING DOORS 37 3s SHALL COMPLY WITH THE AMERICAN NATIONAL STANDARD 39 ~ ; 40 - N STITU E'S - STANDARD 297.1 -- - ---- - -- - ---- 41 '-- ---- - --------- -- :-__._.: -- - -- -- ---i L4 42 - 31 31 - - -- -- - - --------- ----- - -- ------------- ----- ---- --�------------- ---------------- -'--- -- ----- ____ �-- -_ - EXIST. 6 X 12 ; 19 5 31 WOOD BEAM g WINDOWS SHALL BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL - -- - - SD SO AN BE LIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION AND � 22_.5_ FIRST 10 KVA ® 100 = 10.0 KVA REMAINDER ® 40% = 16.2 KVA AS TO COMPLY WITH THE ARCHITECTURAL ALUMINUM MACS _ 15.6 KVA 8 ASSOCIATION STANDARDS FOR FORCE ENTRY RESISTANCE, AAMA 1303.3 A/C © 100% - I: 147.5 AMPS PROVIDE LOCKS AS PER SFBC 3603.2(A),(B)2(AA) AND (C) EXTERIOR TOTAL = 35.4 KVA WINDOW SHALL BE LOCKED WITH DEVICE CAPABLE OF WITHSTANDING A FORCE OF 150 LB. APPLIED IN AN OPERABLE DIRECTION. --- -- -- -------- ------ - - - -- -- ----- - - - -------- ---- - -- - ---- ---- --- - - ------------ 32 10. EXTERIOR WINDOW USED AS A MEANS OF ESCAPE SHALL ALSO COMPLY -31 =- WITH A DOOR SCOPE OR VISION PANELS. k Jy I\\ _ - 31 11 . FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE - � �_� WP --'f ED OR VISION PANELS. �----�------ -_ -_ 31 L LE C TRI CAL GENERAL NOTES 8. ELECTRICAL SYSTEM SHALL BE COMPLETELY GROUNDED AS REQUIRED BY THE 15. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND LATEST ADDITION OF THE N.E.C. TESTINGS. 9. ALL MATERIALS SHALL BE NEW AND SHALL BEAR UNDERWRITERS LABELS 16. THE ELECTRICAL INSTALATION SHALL MEET ALL STANDARD REQUIREMENTS 32 1. DO NOT SCALE ELECTRICAL DRAWINGS. REFER TO ARCHITECTURAL PLANS WHERE APPLICABLE. OF POWER AND TELEPHONE COMPANIES. AND ELEVATIONS FOR EXACT LOCATIONS of ALL EQUIPTMENT AND CONFIRM WITH OWNER'S REPRESENTATIVE. 10. ALL WORK SHALL BE PERFORMED BY A •LICENSED ELECTRICAL CONTRACTOR 17. FURNISH AND INSTALL DISCONNECT SWITCHES AND WIRING FOR AIR IN A FIRST-CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL CONDITIONING SYSTEM AS PER MANUFACTURER RECOMMENDATIONS. CONTROLS 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL BE FULLY OPERATIVE, AND ACCEPTED BY ENGINEER / ARCHITECT. ARE TO BE SUPPLIED BY AIR CONDITIONING CONTRACTOR AND CONNECTED CODE AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES. BY ELECTRICAL CONTRACTOR. 32 j 32 Project: RENOVATION 11. ALL WORK SHALL O COORDINATED WITH OTHER TRADES TO AVOID INTERFER- 18. ALL RACEWAYS UNDERGROUND SHALL BE A MINIMUM OF 3/4" CONDUIT. - -------1 ° 3. MINIMUM WIRE SIZE SHALL BE # 14 A.W.G., EXCLUDING CONTROL WIRING. ENCE WITH THE PROGRESS OF CONSTRUCTION. , UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE COPPER WITH THW 12. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE 19. ALL CIRCUIT BREAKERS TWO OR THREE POLE, TO BE COMMON TRIP. NO TIE INSULATION. FROM DEFECTS FOR A PERIOD OF NOT LESS THAN (1) YEAR FROM DATE HANDLES, OR TANDEMS WILL BE ACCEPTED. FOR: MRS. & MR, BEATY 4. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY OF ACCEPTANCE. 20. ALL FUSES, UNLESS NOTED ON DRAWING, SHALL BE CURRENT LIMITED FUSES WITH THREADED HUBS IN WET OR OR DAMP LOCATIONS AND SPECIAL 13. CORRECTIONS OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL (C.L.) RATED FOR 200,000 A.I.C. ELECTRICAL PLAN---- 6760 S.W. 68th TERRACE ENCLOSURES FOR OTHER CLASSIFIED AREAS. CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER 21• ROMEX IS AN APPROVED ALTERNATE WIRING METHOD IF APPROVED BY OWNER MIAMI, FL. 33143 5. DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUTY, QUICK-MAKE, PHASE OF THE INSTALATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 1 /4 = 1 QUICK-BREAK ENCLOSURES AS REQUIRED BY EXPOSURE. 14. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST Commission Number: 6. MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC, WITH OVERLOAD RELAYS PUBLIC LIABILITY OF PROPERTY DAMAGED FOR THE DURATION OF WORK. IN EACH-'HOT--LEG. _ .. 7. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FORA - -�..°•�-> "4t Drawn b y: 1 [ 0 �. COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY i FOR EQUIPTMENT TO BE PLACED IN PROPER WORKING ORDER. - � ,. •. ►: ' �♦ '; Date: 10/06/00 • �`heet of A - 4 of 5