00-0529-005 AA 0000080 • _ - Suite 100 6401 SW 87th Ave. Miami, Florida, 33173 PLUMBING FIXTURE PIPING SCHEDULE = -- --- --- , (305) 271 - 1000 FIXTURE CW HW TRAP FU REMARKS _ _ William Friedman, R.A. V4 �� AR 0002115 P p1 IN,� WATER CLOSET -WC" 1/2 - 3 4 FLUSH TANK PANTRY D.W. SINK I WATER , / ' / �\ LAVATORY-LAV 1/2 1/2 1-1/4 1 HEATER I I SINK L T BATHTUB-BT 1/2 1/2 1_1/2 2 p O SINK 61 WASHER / / / I ` SHOWER-SH. 1/2 1/2 2 2 RANGE 010 KITCHEN SINK-K.S. 1/2 1/2 1-1/2 2 I t L NEW SINK , i / I T DISHWASHER-DW - 1/2 1.W. 2 <. TUB I /' %/i, REF. REF. PANTRY/i i,', 3/4"CW / CLOTHES WASHER -WM 1/2 1/2 2 4 FROM HWH SUPPLY BIDET I I HOSE BIB-HB 3/4 - - - W/ VAC. BREAKER / I I REFRIGERATOR-REF 3/8 - - - ICE MAKER <\ < V W.C. I OW l ` L. T � \ LAV IN, LAV — EXIST. VENT ' � � �/�"cw ANTI SCALD I '1 I / HW PANTRY D.W. SINK TABLE VALVE SI K HWH VALVE CALD i \ \ I LAV 1 RANGE p 10 _7T LAV w 1 ---------------- • LAV Jc) U '1 REF. REF. PANTRY % ' 0 //"V 2.. WATER ISOMETRIC c I � 4 Fu N TS I 2" vTR ------------ 4" C.I. TO EXIST. p1N I f_�_-- -- �� SEPTIC TANK 2"V.T.R. EXIST. -x:O <,12 Fu BATHROOM I 3 8 FU 3"V.T.R. _L _-J) FU t SH J 0 EXIST 1 ; I _ �'� 1 �i .. �R . 2' 2.. SEPTIC TANK 3 TUB I- N , RAISE EXIST EXIST. 6 X 12 �-- Z ���V_� I EVI► TABLE SINK W. HWH WOOD BEAM -- �Ay co BIDET " DRYER � 3 UNDERII W.C. Co HWH LAV I - � 8 Fu FROM HWH SUPPLY I 1/2" HW FROM EXIST. HWH • LM S • _ PLUMBING ISOMETRIC a I - NTS II 1 /2" HW S2 17-1 PLUMBING GENERAL NOTES : i II 3/4" C.W. . I I 1/2" C.W. 41 _ -- 1. A CLEANOUT SHALL BE PROVIDED AT THE BASE OF EACH SOIL AND WASTE I 1/2" HW II PIPE I � - . ..,,1 �..■ I 2. MINIMUM PITCH OF ALL HORIZONTAL BRANCHES AND SEWER LINES SHALL I �' /11511 ` ass BE 1/8" PER LINEAL FOOT. 3. COORDINATE THE WORK OF THIS TRADE WITH ALL OTHER TRADES. 4. ALL UNDERGROUND PIPING SHALL BE C-PVC. ALL OTHER WATER PIPING SHALL BE COPPER TYPE M. ( �__ • 5. IN GENERAL, ALL WORK OF THIS TRADE MUST COMPLY WITH THE SOUTH �. FLORIDA BUILDING CODE AND ALL OTHER CODES IN EFFECT. EXIST. 6 X 12 ~� S E W E R PLAN 6. VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING WORK AND REPORT WOOD BEAM ANY DISCREPANCIES TO THE ARCHITECT / ENGINEER. — — — — — — — — — — 1/4"=1 ' 7. PROVIDE 1/2" RESEAL LINE FROM WATER SUPPLY TO EACH FLOOR DRAfN. 8. PROVIDE SAFEWASTE FOR AIR CONDITIONING UNIT CONDENSATE WITH TRAP. 9. PROVIDE AIR CHAMBERS FOR ALL WATER SUPPLIES FEEDING FIXTURES. 10. PROVIDE PIPE RELIEF VENT LINE FORM P&T RELIEF VALVE AND PAN DRAINS TO BUILDING EXTERIOR 6" ABOVE GRADE TURNED DOWN. (EACH SEPERATELY) _. 1 1. ALL HOSE BIBS SHALL HAVE VACUUM BREAKERS AND SHUT OFF VALVE. 12. INSTALL ALL FLOOR DRAINS PER SEC. 4613-12. OF THE SOUTH FLORIDA BUILDING CODE. Project: RENOVATION 13. ALL- OUTSIDE CLEANOUTS SHALL BE BROUGHT TO GRADE WITH COVER. 14. PROVIDE CLEANOUTS EVERY 50' FT. INSIDE BUILDING. FOR: MRS. & MR. BEATY 15. PROVIDE INDIVIDUAL SHUT OFF VALVES ON WATER PIPING TO EACH GROUP OF FIXTURES. ti 6760 S.W. 68th TERRACE 16. ALL SOIL, WASTE, VENT, AND RAIN WATER PIPING SHALL BE PVC SCHED. 40 MIAMI, FL. 33143 - 17. INSULATE HOT AND COLD WATER LINES AT WATER HEATER WITH 1 IN. THICK SELF SEALING TYPE INSULATION R= 4.2 MIN.) Commission Number: f Lo ..... '�/e f to Drawn by: J.R.C. • f Date: 08/21 /00 � 4a WASTE ` PLAN '�•,; ••.. . � ►•� •qtr; Sheet of ��°? , A - 5 of 5