00-0087-008 rr r r a a s j. TYPE: CUTLER I--MvER PRLA, ` MAINS: 35A 3P N1CB initial AI�EL"AAP" NG 100 A e �e ._ , . . . NpUVf1N� SURFACE P BUS RATI ngi er,. - AI.C. 18 KA .r Da STI VOLTAGE 120/208V,3PH•4W. _ 14 S.W. n CIR NO. OF DESMI TRIP Po M/oSI,S'Flord 3Terrace r i . — 78(fox) TRIP �iIOR! WIRE� CIR NO. VOLT DESC PT10N WIRE>� s ' CONDUIT N0. POLES ANDS. CONDUIT (305669 9393 �05�s 9-91 N0. POLES ANDS. Alfonso Femondez—Frogo, P.E. 3 ; - - 1 2 1 20 1000 AUDIO RACK EXISTING Florida Mechanical Engineer 3 126 Project No. 980150 3 3 MAIN 4 1 20 1300 GROTTO STAGE RCPT EXI STl NG GENERAL NOTES ELECTRICAL 1 20 loco GROTTO STAGE RCPT oasTln>G . . 5 6 COR � . ELECTRICAL . SYMBOL LEGEND - #12, 1/7 (1) - 20 1000 COMPUTER EXJSUNG 8 1 20 . 1100 IJGHTING! ONS: THE GENERAL CONDITIONS FORM A PART OF THE 500 SPARE CASTELLA 7 GENERAL CONDITI 9 1 20 1000 COMPUTER EX1STlNG 10 1 20 . , , SPECIFICATIONS FOR THIS TRADE AND EACH 11 1 20 1000 BMS Fa00tUl EXISTING 12 1 20 500 SPARE CRIPTIOI�I 13 1 20 500 LASER COMPUTER EXISTING 14 1 = SPACE SYMBOL DES THE GENERAL CONDITIONS AS WELL As THE SPECIFICATIONS FOR WORK _ OF THE OTHER TRADES TO ASCERTAIN WHAT WORK AND MATERIALS HE CARBALLO MUST SUPPLY TO THE OTHER CONTRACTORS. 15 1 - SPACE - INDICATES LIGHTING FIXTURE TYPE. °TYP.':INDICATES _ A THAT ALL SIMILAR FIXTURES WITHIN THE SPACE RESPONSIBILITY OF BIDDERS 17 1 SPACE T HOMPSON ARE OP .THE SAME TYPE, U.O.N. TO VI51 HE E OF THE WORK AND TO ACQUAINT THEMSELVES WITH 2 SITE INVESTIGATION: IT SHALL - T T SITE 19 1 SPACE : ALL INFORMATION REGARDING THE BUILDING. 21 1 . SPACE SAL-MAN" CEILING OUTLET WITH LIGHTING FIXTURE OR DEVICE _ 0 AS INDICATED. 23 1 SPACE : 3 MATERIALS: THE MATERIALS USED SHALL ALL CONFORM TO LOCAL CODE WITH LI TING FIXTURE OR REQUIREMENTS.' ALL MATERIALS USED.SHALL BE L15TED OR SHALL BEAR 1 - SPACE WALL MOUNTED OUTLET GH _ Arc h 1 t e C t S a DEVICE AS INDICATED. U.L. APPROVAL. 27 1 SPACE _ 29 1 - SPACE Engineers FLUORESCENT LIGHTING FIXTURE. 4 DESIGN: THE INSTALLATION OF THE WIRING SYSTEM ON THESE FLUORESCENT FIXTURE WITH EMERGENCY BATTERY PACK. DRAWINGS SMALL CONFORM TO THE REGULATIONS OF THE LOCAL CODES P I a n n e r S ®' OR IN EMERGENCY CIRCUIT AND ORDINANCES, N.E.G. AND LOCAL UTILITY COMPANIES. 901 Pena!de Leon BrMd„Sutte 9Q0 Cow! C IM Dodds •33134 CEILING OR WALL MOUNTED EXIT LIGHT FIXTURE WITH 5 GUARANTEE: THE SUB-CONTRACTOR SHALL FURNISH A WRITTEN 3foo 1soa�4ao2a ARROWS AS INDICATED. GUARANTEE THAT ALL WORK EXECUTED UNDER TH15 CONTRACT SHALL BE EHOOOJo�t AACooQ 2 FREE FROM DEFECTS, OF WORKMANSHIP AND MATERIALS FOR A PERIOD OF DUPLEX CONVENIENCE RECEPTACLE, 113" A.F.FJU.O.N. ONE YEAR FROM THE DATE OF THE FINAL ACCEPTANCE AND THAT HE . 0= QUAD (DOUBLE DUPLEX) RECEPTACLE. WILL AT HIS OWN EXPENSE, REPAIR AND REPLACE ALL WORK W141CH SUB-TOTAL 3500 5400 • BECOMES DEFECTIVE DURING V9 TIME OF THE GUARANTEE. SUB-TOTAL 5400 L 8900 CON�ETED LOAD) ' DUPLEX OUTLET WITH ISOLATED GROUND. TOTAL ) 6 CONDUCTORS: ALL CONDUCTORS MAY BE OF 9BX CONDUCTIVITY COPPER LOAD: 8.9 KVi4 24.7A DUPLEX CONVENIENCE OUTLET, HORIZONTALLY MOUNTED OR ALUMINUM EQUIVALENT. CONDUCTOR INSULATION SHALL BE TYPE THw CAPACITY PR(7VIDED 35A ABOVE COUNTERTOP OR BACKSPLASN. OR THWN FOR NO. B AWG AND LARGER AND TYPE TNHN�ii IWN FOR N0. 10 WP INDICATES WEATHERPROOF. AWG SMALLER UNLE55 OTHERWISE NOTED ON PLANS OR IN THE NOTES &WP a SCHED (1) PROM DE NEW G ROUT BAR I N AVAI LABLE MEL SPACE CLOCK OUTLET, AT 7'-6 ABOVE FLOOR, UNLESS INDICATED OTHERWISE. 7 RACEWAYS: ALL CONDUCTORS SHALL BE IN RACEWAYS AS FOLLOWS: SPECIAL PURPOSE RECEPTACLE, AS INDICATED ON DRAWINGS. FLEXIBLE CONDUIT CONNECTION. A PVC SCHEDULE 40 SHALL BE USED UNDERGROUND, IN CONCRETE, OR UNDER GROUND FLOOR SLAB. ' rn... dra.:Mp m le nopeft nr. - TYPE: CUTLER HAMMER PRLA MAINS: 100A-3P MCB „�, m "„ rw �,�,-o, INDICATES CONDUIT RUN, UNDERGROUND UNLESS INDICATED OTHERWISE. a I.M.C. OR R.G.S.C. SHALL BE USED WHERE EXPOSED OUTDOORS MOUNTING: SURFACE PANEL"MSL" BUS RATING' 100 A ,� m� INDICATES CONDUIT RUN CONCEALED UNLESS INDICATED A.I.C. 18 KA EXISTING VOLTAGE: 1201208V,3 PH. 4W. M to wna. UP TO A POINT 12' BELOW GRADE WHERE TRANSITIONS TO PVC • CIR NO. OF TRIP VOLT DESCRIPTION WIRE & CIR NO. OF TRIP VOLT DESCRIPTION WIRE 8: d p� �� �� OTHERWISE. SHALL BE MADE. INDICATES HOME RUN TO PANEL OR LOCATION INDICATED. NO. POLES AMPS. CONDUIT N0. POLES AMPS. CONDUIT °A' INDICATES PANEL W. TICKS DENOTE THE NUMBER OF G FLEXIBLE CONDUIT SHALL BE USED FOR CONNECTION TO ALL 1 1 20 1080 RECEPTACLES EXISTING 2 VIBRATING EQUIPMENT AND TO ALL RECESSED MOUNTED FIXTURES. 2 30 4000 CHARGER RECEPT. EXISTING J O B N U M B E R A-1,3,5 CONDUCTORS. /PNDICATES GROUND WIRE. NO TICKS 3 1 20 1080 RECEPTACLES F�CISTING 4 OR A-I/3/5 INDICATES TWO (2) WIRES. COMMAS SEPARATE SINGLE POLE FLEXIBLE CONDUIT SHALL BE LIQUID-TIGHT WHERE EXPOSED TO LE WEATHER. FLEXIBLE 5 1 20 1000 MERCHANDISE CART EXISTING 6 BRANCH CIRCUITS; SLASHES SEPARATE DIFFERENT POLES 2 30 4000 CHARGER RECEPT. TING MULTIPOLE BRANCH CIRCUITS. 7 1 20 1000 MERCHANDISE CART EXISTING 8 1933—1� D ELECTRICAL METALLIC TUBING MAY BE USED INDOORS, WHERE 9 1 20 1000 MERCHANDISE CART EXISTING 10 1 20 900 LIGHTS EXISTING of JUNCTION BOX, FLUSH MOUNTED IN CEILING, U.O.N. CONCEALED, ABOVE GRADE. 11 1 20 1000 MERCHANDISE CART EXISTING 12 1 20 1000 LIGHTS EXISTING • • . JUNCTION BOX FLUSH MOUNTED IN WALL, � E ELECTRICAL NONMETALLIC TUBING AND/OR SHEATHED NONMETALLIC (1) 13 1 20 600 VENDING MACHINE #12 1/2 14 1 20 720 RECEPTACLES #12 1/2" (1} � " (1) 15 1 20 600 VENDING MACHINE #12 1/2" 16 1 20 720 RECEPTACLES #12 1/2" (1) REV t S i O N S 7 -6 A.F.F./U.O.N. CABLE MAY BE USED WHERE PERMITTED BY CODE. 17 1 20 SPACE - 18 1 20 900 RECEPTACLES #121/2" (1) TELEPHONE OUTLET, IB' A.F.F./U.O.N. TELEPHONE/DATA OUTLET, IB° A.F.F./U.O.N. DATA/COMPUTER OUTLET IB°AFF/U.O.N. Q " INDICATES OUTLET OR DEVICE MOUNTED 4B" ABOVE FLOOR. 48 ® MAGNETIC MOTOR STARTER OR CONTACTOR. ELECTRIC DUCT HEATER t DISCONNECT. EXISTING STEP DOWN TRANSFORMER 9KVA-3PH- CODE 51ZED t RATED DISCONNECT SWITCH. 4BO-120/20BV E(15TING 15A so FUSED DISCONNECT SWITCH: 3=N0. OF POLES; 60=SWITCH o SIZE; 50-FUSE SIZE. (0 INDICATES NON-FUSED ). FEEDER FEEDERG 40A SUB-TOTAL 7360 12240 © THERMOSTAT. FEEDER SUB-TOTAL 12240 • PUSHBUTTON MOUNTED 4'-00 A.F.F./U.O.N. (— TOTAL 19600 (CONNETED LOAD) ❑ , - - PNL PNL I pNL CONNECTED LOAD: 19.6KVA-54.4A CAPACITY PROVIDED-100A , a TRANSFORMER. I MSL I I PNL I `T _I I ,gyp, I NOTES: _I_ (1) PROVIDE NEW CIRCUIT BREAKER IN AVAILABLE EXIST. EXIST. _ EXIST. �, MANUAL MOTOR STARTER W/ OVERLOADS, 4B° A.F.F./U.O.N. I I I I I I PANEL SPACE. SINGLE POLE TOGGLE SWITCH, 20A, 120/277V, MOUNTED S 4'-0' A.F.F./U.O.N. I So . DIMMER SWITCH THREE WAY AND 4 WAY TOGGLE SWITCHES, 20A, 1201277V, EXISTING IOOA I ( EXISTING 50A S3. S 4 MOUNTED 4'-0" A.F.F./U.O.N. FEEDER FEEDER SP SWITCH WITH PILOT LIGHT,. MOUNTED 4'-01 A.F.F./U.O.N. I . r-° ELECTRIC.PANELBOARD 120/20BV-3o-4W �_ ELECTRIC MOTOR. 'DM' INDICATES A/C DAMPER MOTOR. REFS I/E-3 REFER TO DETAIL I, SHEET E-3. 30 KVAG 3 PH, 480-120/220BN�SFORMER 1 PARKING LOT LUMINAIRE, .POLE AND POLE BASE. - ELECTRICAL RISER D CONDUIT ELBOW DOWN N.T.S. CONDUIT STUB UP ' © POWER OUTLET BOX FOR MODULAR FURNITURE " " o F I L E • CONNECTION . 4x4 x2 3/4 W/.BRUSHED STAINLESS STEEL_.COVER PLATE. P L 0 T : 100% COMBINATION TELEPHONE/COMPUTER DATA OUTLET' : FOR MODULAR"FURNITURE CONNECTION. 4'x4"x2 3/4" . USN STAINLESS STEEL COVER PLATE. D R A w N MA/CJ f : W/BR ED : CHECKED A c NOTES: 1- 'NOT ALL SYMBOLS ARE USED. D A 15J T E AN93 2- WP.:DENOTES WATERPROOF. 3 E DENOTES EXISTING. 4- R DENOTES RELOCATED. Q a W a a d. p _ U c Z o Q o °o E ZL• � � � 0 0. * ' 3. 0 0 0 3 dQ _ tLo SHEET INDEX • SCHEDULES, - NOTES,LEG ,• a - SHEET NUMBER E-2