Loading...
00-0683-013 DATE REVISION ELECTRICAL SCHEDULE FOR EACH APT. IN BLDG. 1,2,3 ELECTRICAL SCHEDULE FOR EACH APT. IN BLDG. 4 -- - PANELBOARD MAINS TYPE 125 AMPS 1-PHASE 3-WIRE 2401120 VOLTS MOUNTED SM PANELBOARD MAINS TYPE 1Z5 AMPS 1-PHASE 3-WIRE 240/120 VOLTS MOUNTED SM MANUFACTURER• a-70,D TYPE SCIC= A000 4tA r MANUFACTURER SQ,D TYPE scic= �D,oOOAMP KITCHEN OR BATHROOM BRANCH LOAD BREAKER CIRCUIT BREAKER LOAD BRANCH SMOKE DETECTOR BRANCH LOAD BREAKER CIRCUIT BREAKER LOAD BRANCH CIRCUIT No. CIRCUIT CIRCUIT No: CIRCUIT - p F F F W C K R T T R K W C SD W C K R T T R K' W C 1 O DESCRIPTION V A R R A V DESCRIPTION 1 0 1 O DESCRIPTION V A R R A V DESCRIPTION 1 0 R N A M t I M A R N 120 V. R N A M 1 I M A R N E D E P P E E D SWITCH LINE SIDE E D E P P E E D- - _ OF SWITCH 12 '/" REFRIGERATOR .9 20A 1 2 OA 11.7 RANGE&OVEN 6 12 %z" REFRIGERATOR .9 20A 1 2 50A 11.7 RANGE&OVEN 6 %" 10 %z" WATER HEATER 3.0 30A 3 4 SWITCr1 LEG. 8 '/" WATER HEATER 'T.5 50A 3 4 ° " PHASE CONDUCTOR " " 5 6 20A 1.5 SMALL APPL 12 %:" " 5 6 20A 1.5 SMALL APPL 12 '/:" 12 '/z' DISHWASHER 1.2 20A 7 8 20A 1.5 SMALL APPL. 12 '/" 12 '/" DISHWASHER 1.2 20A 7 8 20A 1.5 SMALL APPL. 12 %" 14 '/z" GEN. LIGHTING 15A 9 10 15A 2.1 GEN. LIGHTING 14 '/z" NOTE: 14 '/° GEN. LIGHTING 15A 9 10 15A 2.1 GEN. LIGHTING 14 '/z" 6 3/." A/C&HEAT 5.5 50A 11 12 15A GEN. LIGHTING 14 %" SMOKE DETECTOR SHALL BE HARDWIRED 1110 VOLT TYPE) TO A NON-SWITCHABLE KITCHEN (� 3�" A/C&HEAT 5.5 50A 11 12 15A CiEN. LIGHTING 14 �" " " . OR BATHROOM LIGHTING CIRCUIT, WITH BATTERY BACK-UP AND SHALL NOT BE CONNECTED 13 14 20A DEDICATED 12 ONTO THE LOAD SIDE OF GROUND FAULT CIRCUIT INTERRUPTER. ALL SMOKE DETECTORS 13 14 20A DEDICATED 12 W WITHIN EACH UNIT SHALL BE INTERCONNECTED. 10 A/C CONDENSOR (2.1) 30A 15 16 20A 1.5 RANGE HOOD 12 %" 10 3/4" A/C CONDENSOR (2.1) 30A 15 16 20A 1.5 RANGE HOOD 12 19 3/" "SPARE " 17 18 SPARE 20 'SMOKE DETECTOR CONNECTION DETAIL N. T .S. SPARE 19 20 SPARE 21 22 21 22 q..6 18.3 KVA 5.1 +A/C 5.5 18.3 KVA TOTAL CONNECTED LOAD = 21.9 + A/C & HEAT 5.5 KVA TOTAL CONNECTED LOAD = 23.4 + A/C 5.5 FIRST 10 KVA= 10 KVA FIRST 10 KVA= 10 KVA NEXT 17.9 KVA @ 40 % = 7.1.6 KVA NEXT 13.4 KVA @ 40 % = 5.4 KVA A/C HEAT & FAN= 5.50 KVA A/C HEAT & FAN = 5.5 KVA 2.265 KVA/ 240 = 94 AMPS 20.9 KVA 1240 = 87 AMPS ARCHITECT: FILER & HAMMOND ARCHITECTS, INC. ARCHITECT: FILER & HAMMOND ARCHITECTS, INC. ARCHITECT: FILER & HAMMOND ARCHITECTS, INC. ARCHITECT: FILER & HAMMOND ARCHITECTS, INC. o PROJECT: REFURBISH 4 APARTMENT BLDGS. PROJECT: REFURBISH 4 APARTMENT BLDGS. PROJECT: REFURBISH 4 APARTMENT BLDGS. PROJECT: REFURBISH 4 APARTMENT BLDGS. . F&H COMM. NO.: 0022 F&H COMM. NO.: 0022 F&H COMM. NO.: 0022 F&H COMM. NO.: 0022 1999 NEC 220-30 OPTIONAL CALCULATIONS FOR MULT. DWELLING UNITS. 1999 NEC 220-30 OPTIONAL CALCULATIONS FOR MULT. DWELLING UNITS 1999 NEC 220-30 OPTIONAL CALCULATIONS FOR MULT. DWELLING UNITS. 1999 NEC 220-30 OPTIONAL CALCULATIONS FOR MULT. DWELLING UNITS APARTMENT BUILDINGS NO. 4 APARTMENT BUILDINGS NO. 4 APARTMENT BUILDINGS NO. 1, 2, & 3 APARTMENT BUILDINGS NO 1 2 & 3 ,LO� COMPUTED LOAD FOR EACH BUILDING VA EACH APARTMENT BUILDING HAS 8 UNITS. COMPUTED LOAD FOR EACH BUILDING VA EACH APARTMENT BUILDING HAS 8 UNITS. GENERAL LIGHTING 2100 VA If UNIT X 8 UNITS 16800 EACH APARTMENT IS IDENTICAL. GENERAL LIGHTING 2100 VA / UNIT X 8 UNITS 16800 EACH APARTMENT IS IDENTICAL. a► V SM. APPLIANCE CIRCUITS - 3000 VA / UNIT X 8 UNITS 24000 EACH APARTMENT IS 702 SQ. FT. (OUT OT OUT) SM. APPLIANCE CIRCUITS - 3000 VA / UNIT X 8 UNITS 24000 EACH APARTMENT IS 702 SQ. FT. (OUT OT OUT) V 0 RANGES - 11700 VA / UNIT X 8 UNITS 93600 EACH APARTMENT IS SERVED BY A 2-TON RHEEM A/C SPLIT SYSTEM. RANGES - 11700 VA / UNIT X 8 UNITS 93600 EACH APARTMENT IS SERVED BY A 2-TON RHEEM A/C SPLIT SYSTEM. DISHWASHER , 1200 VA / UNIT X 8 UNITS 9600 EACH APARTMENT HAS AN EXISTING 3000 WATT HOT WATER HEATER. DISHWASHER , 1200 VA / UNIT X 8 UNITS 9600 EACH APARTMENT HAS AN EXISTING 3000 WATT HOT WATER HEATER. LL REFRIGERATORS - 900 VA / UNIT X 8 UNITS 7200 EACH APARTMENT HAS A GE RANGE / OVEN RATED 1 1.7 KW. REFRIGERATORS - 900*VA / UNIT X 8 UNITS 7200 = EACH APARTMENT HAS A GE RANGE / OVEN RATED 11.7 KW. INLINE ELEC. HOT WATER HEATER - 7500 VA / UNIT X 8 UNITS 60000 HOT WATER HEATER - 3000 VA / UNIT X 8 UNITS 24000 RANGE HOOD - 1500 VA / UNIT X 8 UNITS 12000 COMPUTED LOAD FOR EACH DWELLING UNIT. VA RANGE HOOD - 1500 VA / UNIT X 8 UNITS 12000 COMPUTED LOAD FOR EACH DWELLING UNIT. VA TOTAL 223200 GENERAL LIGHTING [TABLE 220-3(B)) - 702 SQ. FT. @ 3 VA / SQ.FT. 2100 TOTAL 187200 GENERAL LIGHTING [TABLE 220-3(B)) - 702 SQ. FT. @ 3 VA / SQ.FT. 2100 A APPLIANCE CIRCUIT - 2 @ 1500 VA 3000 APPLIANCE CIRCUIT- 2 @ 1500 VA 3000 L NET COMPUTED LOAD - OPTIONAL CALCULATION TABLE 220-32 RANGE 11700 NET COMPUTED LOAD - OPTIONAL CALCULATION TABLE 220-32 RANGE 11700 4=0 7m 223200 VA X 0.43 = 95976 DISHWASHER 1200 187200 VA X 0.43 = 80496 DISHWASHER 1200 m ' Q, REFRIGERATOR 900 REFRIGERATOR 900 SERVICE ENTRANCE CONDUCTORS INLINE ELECTRONIC HOT WATER HEATER 7500 SERVICE ENTRANCE CONDUCTORS HOT WATER HEATER 3000 1 = 95976 VA / 240 V = 400 AMPS RANGE HOOD 1500 1 = 80496 VA / 240 V = 335 AMPS RANGE HOOD 1500 t NEUTRAL VA TOTAL 27900 TOTAL 23400 j > X NEUTRAL Vq � / � GENERAL LIGHTING 2100 VA / UNIT X 8UNITS 16800 HVAC @ 100 % 5500 GENERAL LIGHTING 2100 VA / UNIT X 8UNITS 16800' HVAC @ 100 % 5500 ® V SM APPLIANCE CIRCUIT- 3000 VA / UNIT X 8 UNITS 24000 OTHER LOAD - 1ST 10000 VA @ 100% 10000 SM APPLIANCE CIRCUIT- 3000 VA / UNIT X 8 UNITS 24000 OTHER LOAD - 1ST 10000 VA @ 100% 10000 REFRIFGERATOR - 900 VA / UNIT X 8 UNITS 7200 REMAINDER OF OTHER LOAD - 27900 - 10000 = 17900 @ 40% 7160 REFRIFGERATOR - 900 VA / UNIT X 8 UNITS 7200 REMAINDER OF OTHER LOAD - 23400 - 10000 = 13400 @ 40% 5360 m RANGE HOODS - 1500 VA / UNIT X 8 UNITS 1200 TOTAL 22660 RANGE HOODS - 1500 VA / UNIT X 8 UNITS 12000 TOTAL 20860 �I TOTAL 49200 TOTAL 60000 � 09%DWELLING UNIT FEEDER (FROM METER TO UNIT PANEL) DWELLING UNIT FEEDER (FROM METER TO UNIT PANEL) !!J DEMAND (TABLE 220-11 1 = 22660 VA / 240 V = 94 AMPS 1 = 20860 VA / 240 V = 86.9 AMPS 1 ) DEMAND (TABLE 220-1 1) d FIRST 3000 VA @ 100% 3000 FIRST 3000 VA @ 100% 3000__ . ■. REMAINDER - 49200 VA - 3000 VA = 4.6200 VA @ 35% = 16170 NEUTRAL VA REMAINDER - 60000 VA -'3000 VA = 57000 VA @ 35% = 19950 NEUTRAL VA d RANGES - 8000 VA (TABLE 220-19) X 8 = 64000 @ 70% = 44800 GENERAL LIGHTING [TABLE 220-3(B)) - 702 SQ.FT. @ 3 VA / SQ. FT. 2100 RANGES - 8000 VA (TABLE 220-19) X 8 = 64000 @ 70% = 44800 GENERAL LIGHTING [TABLE 220-3(B)) - 702 SQ.FT. @ 3 VA / SQ. FT. 2100 TOTAL 63970 APPLIANCE CIRCUIT- 2 @ 1500 VA 3000 TOTAL 67750 APPLIANCE CIRCUIT- 2 @ 1500 VA 3000 REFRIFGERATOR 900 REFRIFGERATOR 900 �J I = 63970 VA / 240 V = 267 AMPS RANGE (11700 @ 70%) 8190 1 = 67750 VA / 240 V = 282 AMPS RANGE (11700 @ 70%) 8190 • RANGE HOOD 1500 RANGE HOOD 1500 FURTHER DEMAND (220-22) TOTAL 15690 FURTHER DEMAND (220-22) TOTAL 15690 / FIRST 200 AMPS @ 100% 200 AMPS FIRST 200 AMPS @ 100% 200 AMPS V REMAINDER @ 70% (67 X .7) 47 AMPS DWELLING UNIT NEUTRAL (FROM METER TO UNIT PANEL) REMAINDER @ 70% (82 X .7) 57 AMPS DWELLING UNIT NEUTRAL (FROM METER TO UNIT PANEL) NEUTRAL 247 AMPS 1 = 15690 VA / 240 V = 65 AMPS. NEUTRAL 257 AMPS 1 = 15690 VA / 240 V = 65 AMPS BUILDING-1 BUILDING 3 00 7. Lu HOUSE PANEL 1 MAINS TYPE 125 AMPS 1-PHASE 3-WIRE 240/120 VOLTS MOUNTED SM HOUSE PANEL 3 MAINS TYPE 125 AMPS 1-PHASE 3-WIRE 240/120 VOLTS MOUNTED SIN H1 MANUFACTURER SQ.D TYPE SCIC=10,000 H3 MANUFACTURER SQ.D TYPE SCIC=10,000 BRANCH LOAD BREAKER CIRCUIT BREAKER LOAD BRANCH BRANCH LOAD BREAKER CIRCUIT BREAKER LOAD BRANCH CIRCUIT No. CIRCUIT CIRCUIT No. CIRCUIT P 4 ■ F I F F F C6 W C K R T T R K W C W C K R T T R K W C 1 0 DESCRIPTION V A R R A V DESCRIPTION 1 0 1 0 DESCRIPTION V A R R A V DESCRIPTION 1 0 R N A M I i M A R N R N A M I I M A R N cl� CD E D E P P E E D E D E P P E E D qAl 12 %" GATE MOTOR .8 20A 1 2 20A .7 GATE 12 %" 12 %z" GATE MOTOR .8 20A 1 2 20A 7 GATE 12 '/z" ! (D 0 12 W. GATE MOTOR .8 20A 3 4 20A .8 FOUNTAIN 12 '/z" 12 W WASHER 1.0 20A 3 4 20A .8 FOUNTAIN 12 %° C== co 12 %z" WASHER 1.0 20A 5 6 20A .8 LIGHTING 12 %" 12 %" WASHER 1.0 20A 5 6 20A 1.0 LIGHTING 12 '/z" m C=L ° 12 %z" WASHER 1.0 20A 7 8 20A .8 LIGHTING 12 '/z" 8 3/4" DRYER 5.4 30A 7 8 20A 1.0 LIGHTING 12 W 8 3/4" DRYER 5.4 30A 9 10 20A .8 FOUNTAIN 12 %" 9 10 LL 11 12 20A .8 GATE MOTOR 12 %z" 8 3/+" DRYER 5.4 30A 11 12 8 3/" DRYER 5.4 30A 13 14 13 14 15 16 12 %" GATE MOTOR 17 18 .8 20A 15 16 DATE: 5/30/00 17 18 19 20 19 20 21 22 21 22 L,IC.#FILER: 3144, 23 22 23 22 HAMMOND: 5159 14.4 4.7 14.4 3.5 COMM. NO.: 0022 TOTAL CONNECTED LOAD=19.1 TOTAL CONNECTED LOAD = 17.9 19100 VA/ 240 = 80 AMPS 17900 VA/ 240 = 75 AMPS TITLE: BUILDING 2 BUILDING 4 HOUSE PANEL 2 MAINS TYPE 125 AMPS 1-PHASE 3-WIRE 240/120 VOLTS MOUNTED SM HOUSE PANEL 4 MAINS TYPE 125 AMPS 1-PHASE 3-WIRE 240/120 VOLTS MOUNTED SIN H2 MANUFACTURER SQ.D TYPE SCIC=10,000 H4 MANUFACTURER SQ.D TYPE SCIC=10,000 SHEET: E-4 BRANCH LOAD BREAKER CIRCUIT BREAKER LOAD BRANCH BRANCH LOAD' BREAKER CIRCUIT BREAKER LOAD BRANCH CIRCUIT No. CIRCUIT CIRCUIT No. CIRCUIT F F F F W C K R T T R K W C W C K R T T R K W C 1 0 DESCRIPTION V A R R A V DESCRIPTION 1 O 1 O DESCRIPTION V A R R A V DESCRIPTION t O R N A M I i I M A R N R N A M I t M A R N 4" E D E P P E E D E D E P P E E D h 12 %" GATE MOTOR .8 20A 1 2 20A .7 GATE 12 '/"' 12 %" GATE MOTOR .8 20A 1 2 20A. .7 GATE 12 12 %" GATE MOTOR .8 20A 3 4 20A 1.0 LIGHTING 12 %" 12 %" GATE MOTOR .8 20A 3 4 20A .8 FOUNTAIN&LIGHT 12 %z" 12 %' WASHER 1.0 20A 5 6 20A 1.0 LIGHTING 12 %° 12 %z" WASHER 1.0 20A 5 6 20A .8 LIGHTING 12 %" 12 %" WASHER 1.0 20A 7 8 12 %z" WASHER 1.0 20A 7 8 20A 1.0 LIGHTING 12 %" 8 3/" DRYER 5.4 30A 9 10 8 '/." DRYER 5.4 30A 9 10 20A 8 GATE MOTOR 12 %" 11 12 11 . 12 ` r Fl (lF 8 3/4" DRYER 5.4 30A 13 14 8 %11 DRYER 5.4 30A 13 14 15 16 1 15 16 ,.� E,� ;.101, , . , 17 18 17 18 19 20 19 20 21 22 21 22 ' 23 24 23 24 ee 22 22 14.4 2.7 14.4 4.1 TOTAL CONNECTED LOAD = 17.8 TOTAL CONNECTED LOAD= 18.5 , .... ..1: 474nn ve 0An - 74 nneoc 18500 VA 1240 = 77 AMPS ,