00-0508-033
STANDARD 3" WIDE HANGERS GENERAL H.V.A.C. NOTES ��p' FASTENED C.U. TO SLAB W/ 4-112"0 x 1-112" 1 A.B. (ONE AT EACH SUPPORT) AND he distances extension to be the sum �A��t0� PROVIDE SOLID ISOLATION PAD of the distances between the hanging 1. The contractor shall furnish all labor, material and equipment - \ wires and the duct size, ID (Smacna) for a complete H.V.A.C. system in accordance with tes drawings. �P� R <^ \ FOR CORROSION INHIBITOR Duct size, Inches Maximum Hanger The South Florida Building Code and the latest edition of the Spacing following Publications: P g (o ANS 89.1 Mechanical Refrigeration (b) NFPA Pamphlets 90A & 91 48: Wide or grater 4 ft ,r, p (c) SMACNA (d) ASHRAE. Less tho 48" wide 6ft �p 2. All air conditioning ductwork shall be 1-1/2 " standard duty 2. All air conditioning ductwork shall be code gauge galvanized and less than 48" �0 foil reinforced fiberglass (R-6) manufactured logo rinted on the metal duct with exterior wrap around fiberglass insulation (R-6) for CONDENSING - POWER & CONTROL deep vapor barrier when in uncond( Coned space, and 3� standard duty unconditioned space and (R-4) for conditioned space and shall be UNIT LOCATION P �P foil reinforced fiberglass (R-4� manufactured logo printed on the installed as per standard regulations. Width between 28" 6ft 9 pd1 vapor barrier in conditioned space or return plenum space. & 48" and greater ip� 0.42 than 16" deep r � � e /i�� 3. All exhaust ductwork shall be code gage galvanized sheet metal. p° 1 0 (�° >, Less then 29" wide Sft d � and 16 depth or less 1-11, II 4. Duct size shown are net free area inside. i� II II II I 5. All air devices (diffusers, registers and grilles) shall be all . LIQUID LINE W/ 0 II aluminum construction, with exposed surface chemically treated to INSULATION CHANNEL SECTION II 8 y receive paint to match color or AIR GUIDE or approved .e ual CONCRETE BASE q W 16X6-10110 WWF If Total Minimum Minimum 6. Provide opposed blade dampers at all diffusers and registers. % �� % � Extension is Channel Channel 7. Thermostats shall be combination cooling heating with system not greater than: Gauge Profile i Cool / Auto / Heat / Off and Fan On /Auto selector switches. e �� 8. Refrigerant piping shall be copper type "L" with 112" armaflex. SUCTION LINE 6 24 3" X 1.5" y Insulation shall be provided for suction lines. 18" 22 3" X 2" 30 W/ 1/2 ARMAFLEX 18 3" X 2" 9. Provide new filters for fan coil before starting. These filters must also be replaced prior to final acceptance by owner. UNIT MUST BE INSTALLED TO INSULATION & VAPOR WITHSTAND 125 MPH BARRIER USE OF 2" WIDE 10. General contractor is to hire an independent Test and Balance HURRICANE FORCE WINDS 22 gauge 2'x 1.5" hangers may be substituted company which shall provide 3 set of the report sign and sealed for 3" hangers for ducts with widths not over 48" HANGERS AND SUPPORTS- by the Professional Engineer from the company prior of acceptance and depths not over 24" provided that not more of work. than one joint occurs between hangers and the 10. Mechanical contractor its to provide turnip vent at all change of directions CU MOUNTING DETAIL maximum hanger spacing 4ft. Exception: When P 9 9 duct perimeter is 80" or less and does not or to provide turning radio, all outlets shall have extractors or scuppers. require reinforcement two joints are permitted and shall be installed in accordance with the applicable regulations. N.T.S. between hangers i t ROOF STRUCTURE PROVIDE W/P. CAP LOW PROFILE SEE ARCHITECTURAL B.D.D. AT TOP FOR DRYER. FAN-COIL NO SCREEN FOR BATHROOM PROVIDE INSECT SCREEN MBTUH ENTERING F ELECTRICAL DATA REF. OBS DESIGNATION CFM WIRE TOTAL SENSIBLE WB DB VOLTS PHASES HTNG KW AMPS FUSES MANUFAC. UNIT LIQ. SUC. COND. 4-16d NAILS �� AHU-1,3,4 2000 56.0 41.4 80 67 240 1 10 44 60 RHEEM RBHA24J 10SU6Al 318 1-118 1 THRU PLYWOOD 6 eM�TN 6'CLEAR FROM AHU-2 1200 35.6 25.4 80 67 240 1 5 24 30 RHEEM RBHA1750SUDAI 318 314 1 A FINISH ROOF I SR Y DUCT FROM UNIT (SEE PLAN FOR SIZ SIZE & TYPE) e I ` 1°MIM I TYPICAL ROOF CAP DETAIL CONDENSING UNIT TEMP, ENT, ELECTRICAL DATA REF. OBS OR SEER SEE SI @ DRYER AND/OR TOILET EXH. DESIGNATION MBTUH CONDENSER VOLTS PHASES WIRE AMPS FUSES MANUFAC. UNIT AREA SERVED ` I 2 N.T.S. n' T o F� CU-1,3,4 56.0 95 240 1 34 60 RHEEM RAKA060JAZ 10.15 SHOWN �+ o p rnrZ 1 CU-2 35.6 95 240 1 22 30 RHEEM RAKA077JAZ 10.15 SHOWN ■ W LID •MIM C/) o M STRAP AS PER SMACNA 2,12 LI J d PROVIDE ALUMINUM TAPE _J M COVERING STRAP & JOINT r (NOT SHOWN FOR CLARITY) V (Y)CO CEILING (� U _J DISCHARGE BOX DETAIL �i Q ILL (SMACNA 2.16) NTS COIL T WALLS ® � M J Co REF. LINES FAN SECTION ►� Q J FILTER ACCESS a < COND. LINE O SEE PLUMBING U - DUJCx. PREFAB MTL. FRAME P.P. 4"0 EXHAUST DUCT A/C CLOSET INSTALLATION N.T.S. f� AT 1` STEEL HANGER WIRE �? LEGEND `° 24X24 CD-(SEE SCHEDULE) HVAC DESIGN REQUIRE: YES NO o DUCT TO MATCH NECK SIZE TYP. THEN RUN REF. PIPING Ny CEILING GRILLE SEE SIZE SCHEDULE DUCT SMOKE DETECTOR X + M M co TYPICAL CEILING CABINET IN WALL SPACE DUCT TO MATCH NECK SIZE TYP. FIRE DAMPER(S) X V EXHAUST FAN WITH BACKDRAFT PACK VOID SW/ ARMAFLEX SMOKE DAMPERS X W1 SILICONE © 24X48 RAG-( SEE SCHEDULE) w C DAMPER, LOW NOISE LEVEL & COAT F GH FIRE RATE ENCLOSURE X CO m SEALANT FOR TIGH ' VOLUME DAMPER AND NO VIBRATION. FIRE RATED ROOF FLOOR CEILING ASSEMBLY X � CLOSURE HARD TUBING ROOF/ 171 1 FLOOR THERMOSTAT FIRE STOPPING X -ter- 07 SOFT TUBING SMOKE CONTROL X W DUCT MOUNTED SMOKE DETECTOR -J I" M) —LJ SEE F.A. RISER FOR SPECS. m FRONT FACE GRILLE WITH < FASTENING SCREENS a _ AIR FLOW DIRECTION ( ARROWS DENOTE a 1 WAY, 2 WAY, ETC., SEE PLANS < Q RETURN OR EXHAUST, SEE PLANS. Z Q EXHAUST FAN BI BRACKET LE O W (ADJUSTABLE) CONCRETE SLAB WALL MOUNTED SIDE REGISTER. CEILING MOUNTED CABINET REFRIGERANT LINES SLAB • ELECTRICAL EXHAUST FAN DETAIL PVC PIPE-RUN UNDER SLAB J CD EXHAUST FAN • MECHANICAL • PLUMBING SEE FLOOR PLAN FOR LOCATION OAI. OUTSIDE AIR INTAKE w F z ( / ) W CARLOS M. N. S. SCH. 40 W SOLVENT WELD JOINTS W USE 4" OR 5" PIPE AS REQUIRED S.R SIDE REGISTER Wp BARRENECHEA Q Z 0 PRESIDENT J co CEILING DIFFUSER _p 4936A S.W. 74 CT. Nt N !!. MIAMI, FLA. O T_ REFRIGERANT LINE PIPING DETAIL. ;=' ,, ''I II 33 1 55 CV co CEILING GRILLE �" ?�' 11 ' OFFICE = NOTES: . � H.P. HEAT PUMP UNIT III W (305) 665-7759 ;e f,,yr. s r� Fax 1. CONCEALED OR NOW REMOVABLE JOINTS SHALL NOT BE INSTALLED ;�� ; (3❑5) 665-7758 BELOW SLA _ 2. PVC. S H. 40 SLEEVE SHALL BE 2" LARGER THAT THE PIPE INSULATION co CEILING GRILLE Ile E E ENCASED. HAVING AN ANGLE NO GREATER THAN 45 DEGREES WITH THE U.O.N. UNLESS OTHERWISE NOTED. ' a t', t4 L.C. N O. E B❑❑❑7 1 5❑ ENCASED REFRIGERANT PIPING REMOVABLE FOR REPLACEMENT. 1 P.E. No. 0053288 JOSE A. MENDEZ M-2 l MECHANICAL ENGINEER JA L�