00-0508-002
STANDARD 3" WIDE HANGERS anget extension to be the sum GENERAL H V A C NOTES FASTENED C.J.-TO;SLAB 'y °4-:;1 2 x " - ^.RT)^AND wires 1 the distances between the hanging . The contractor shall furnish all labor, material and equipme �(P FR A.B. (ONE A7 PROVIDE SOLID EACF�„SUPQ ISOLATION PAD wres and the duct size, ID (Smacna) for a complete H.M.C.H. .C. system in accordance with these drawings. Duct size, Inches Maximum Hanger The South Florida Building Code and the latest edition of the �P�R FOR CORROSION INHIBITOR Spacing following publications: GV a ANS 89.1 Mechanical Refrigeration (b) NFPA Pamphlets 90A & 91 � - p (c) SMACNA (d) ASHRAE. 48: Wide or grater 4 ft ® - Less tha 48" wide 6ft �PgR 2. All air conditioning ductwork shall be 1-1/2 standard duty 2. All air conditioning ductwork shall be code gauge galvanized and less than 48 Off• foil reinforced fiberglass (R-6) manufactured logo rioted on the metal duct with exterior wrap around fiberglass insulation R-6 for ( l CONDENSING deep vapor barrier when m unconditioned space, and 3� , standard duty unconditioned space and (R-4 for conditioned space and shall be UNIT POWER & CONTROL �pP foil reinforced fiberglass (R-4) manufactured logo printed on the installed as per standard regulations. Width between 28" 6ft �II vapor barrier in conditioned space or return plenum space. LOCATION & 48" and greater i� W�I�'� than 16" deep � � ./I 0 3. All exhaust ductwork shall be code gage galvanized sheet metal. Less then 29" wide 8ft p O° 1',O,. and 16 depth or less II 4. Duct size shown are net free area inside. � II \ II II I 5. All air devices (diffusers, registers and grilles) shall be oil ' CHANNEL SECTION p s I aluminum construction, with exposed surface chemically treated to LIQUID LINE W/ 0 INSULATION ' > I receive pp q CONCRETE BASE t �L paint to match color or AIR GUIDE or approved equal. If Total Minimum Minimum 6. Provide opposed blade dampers at all diffusers and registers. w 16x6-10 110 wwF Extension r Channel Channel i/���' 7. Thermostats shall be combination cooling heating with system not greater than: Gauge Profile ��� Cool / Auto / Heat / Off and Fan On Auto selector switches. 6" 24 3" X 1.5" �% y 8. Refrigerant pipin shall be copper type "L" with 112" armaflex. 18' 22 3" X 2" � g insulation shall e provided for suction lines. 30 SUCTION LINE 18 3" X 2" 9. Provide new filters for fan coil before starting. These filters must also be replaced prior to final acceptance by owner. W/ 112 ARMAFLEX USE OF 2" WIDE UNIT MUST BE INSTALLED TO INSULATION & VAPOR 10. General contractor l WITHSTAND 125 MPH BARRIER to hire an independent Test and Balance 22 gauge 2'x 1.5" hangers may be substituted company which shall l provide. 3 set of the report sign and sealed HURRICANE FORCE WINDS for 3" hangers for ducts with widths not over 48" HANGERS AND SUPPORTS— by the Professional Engineer from the company prior of acceptance and depths not over 24" provided that not more of work. than one joint occurs between hangers and the 10. Mechanical contractor its to g g CU MOUNTING DETAIL maximum hanger spacing Oft. Exception: When or to provide turning radio, all outlets rshal! have aextra extractors or scuppers.) ions t 'l.0 11 j duct perimeter is nt or less and does not and shall be installed in accordance with the applicable regulations. require reinforcement two joints are permitted between hangers N.T.S. .T ROOF STRUCTURE PROVIDE W/P. CAP LOW PROFILE SEE ARCHITECTURAL B.D.D. AT TOP FOR DRYER. FAN—COIL NO SCREEN FOR BATHROOM PROVIDE INSECT SCREEN MBTUH ENTERING F ELECTRICAL DATA OBS DESIGNATION CFM WIRE REF, TOTAL SENSIBLE WB DB VOLTS PHASES HTNG KW AMPS FUSES MANUFAC. UNIT U0. SUC. COND. 4-16d NAILS THRU PLYWOOD AHU-1,3,4 . 2000 56.0 41.4 80 67 240 1 10 44 60 RHEEM RBHA244110SU6A1 3/8 1-118 1 r SIN le 6 NGTN 6"CLEAR FROM AHU-2 1200 35.6 25.4 80 67 240 1 5 24 30 RHEEM RBHA1750SUDAI 3 8 3 ASR FINISH ROOF 4 1 / / I e 1MIN I �`�� W 8Y GR DUCT FROM UNIT Ill (SEE PLAN FOR h I SIZe SIZE & TYPE) Z ` 1*MIN. I TYPICAL ROOF CAP DETAIL CONDENSING UNIT / ` I SEMIS ® DRYER AND/OR TOILET EXH. TEMP. ENT. ELECTRICAL DATA REF. OBS OR SEER \ G�\�� 1•MI E pIA ZE DESIGNATION MBTUH CONDENSER VOLTS PHASES WIRE AMPS FUSES MANUFAC. UNIT AREA SERVED N.T.S. _ o CU-1,3,4 56.0 95 240 1 34 60 RHEEM RAKA060JAZ 10.15 SHOWN 00 rn 1'M CU-2 35.6 95 240 1 22 30 RHEEM RAKA077JAZ 10.15 SHOWN ■ IN (n LO STRAP AS PER SMACNA 2.12 C') PROVIDE ALUMINUM TAPE COVERING STRAP & JOINT V J t (NOT SHOWN FOR CLARITY) 0 J CO CEILING �U c DISCHARGE BOX DETAIL � o (SMACNA 2.16) NTS COIL/HEAT WALLS o 07 LL SECTION ■�� m W FAN SECTION REF. LINES = Q J _J FILTER ACCESS--,, Q O J Q Ix SE' — E PLUMBING O DWG. () PREFAB MTL. FRAME P.F. 4"0 EXHAUST DUCT A/C CLOSET INSTALLATION / N.T.S. STEEL HANGER WIRE d- LEGEND 24X24 CD—(SEE SCHEDULE) HVAC DESIGN REQUIRE: YES NO LO DUCT TO MATCH NECK SIZE TYP. C) Fa THEN RUN REF. PIPING DUCT SMOKE DETECTOR CEILING GRILLE SEE SIZE SCHEDULE X TYPICAL CEILING CABINET IN WALL SPACE DUCT TO MATCH NECK SIZE TYP. FIRE DAMPER(S) X (0 EXHAUST FAN WITH BACKDRAFT PACK VOID SWK ARMAFLEX 24X48 RAG— SMOKE DAMPERS X m DAMPER, LOW NOISE LEVEL & COAT W� SILICONE ©` RAG—( SEE SCHEDULE) AND NO VIBRATION. SEALANT FOR TIGH FIRE RATE ENCLOSURE X VOLUME DAMPER CLOSURE HARD TUBING FIRE RATED ROOF/FLOOR CEILING ASSEMBLY X ri SOFT TUBING OT THERMOSTAT FIRE STOPPING X SMOKE CONTROL X = U7 CD� UW DUCT MOUNTED SMOKE DETECTOR J FRONT FACE GRILLE WITH �� MI D SEE F.A. RISER FOR SPECS. m FASTENING SCREENS a _ AIR FLOW DIRECTION ( ARROWS DENOTE (� 1 WAY, 2 WAY, ETC., SEE PLANS J a Q Z 0 EXHAUST FAN HANGING RETURN OR EXHAUST, SEE PLANS. O BRACKET (ADJUSTABLE) O H CONCRETE SLAB � \ WALL MOUNTED SIDE REGISTER. CEILING MOUNTED CABINET REFRIGERANT LINES UP ~ w THRU CONCRETE SLAB. EXHAUST FAN • ELECTRICAL � f- L J N Q Q EXHAUST FAN DETAIL PVC PIPE—RUN UNDER SLAB • MECHANICAL N.T.S. SEE FLOOR PLAN FOR LOCATION W • PLUMBING(SCH. 40 W/ SOLVENT WELD JOINTS) 0A.1. OUTSIDE AIR INTAKE z Z USE 4" OR 5" PIPE AS REQUIRED W'" CARLOS M.6.P1 SIDE REGISTER W< SARRENECHEA W Z o PRESIDENT LO ul ,Illlilil /� co CEILING DIFFUSER ��� a 4936A S.W. 74 CT. (V REFRICsERANT LINE PIPM, DETAIL. I` f'9 E��U oC MIAMI, FLA. r 0u 33755 Q d NOTES: co CEILING GRILLE ti` f, l r 1 C� �a Z Z.OFFICE N.P. HEAT PUMP UNIT ; ,� l (30.5) 665-7759 �- 1'�. b3288� FAX 1. CONCEALED OR NOW REMOVABLE JOINTS SHALL NOT BE INSTALLED (305)'665 7758 BELOW SLAB CD 2. PVC. SCH. 40 SLEEVE SHALL BE 2" LARGER THAT THE PIPE INSULATION CEILING GRILLE tij 5 ENCASED. HAVING AN ANGLE NO GREATER THAN 45 DEGREES WITH THE L.C. N o. E e❑o❑7 i s❑ ENCASED REFRIGERANT PIPING REMOVABLE FOR REPLACEMENT. U.OAL UNLESS OTHERWISE NOTED. P.E. No. O❑532BB ,f "S/ I � �. dosE A.'MENDEZ ///��� MECHANICAL ENGINEER � L I / I