Loading...
00-0142-005 ?L U 8 I NG ,L-E- EN NEW 3" VENT J ; ; ' c0 N c0 O .- SANITARY SEVER 'LINE • 3/4„0 o Nt 1 1 /2"0 3"-4 FU U LO VENT LINE CONNECT NEW 3/4” WATER � 3„ ' , , , ' ' , , , , , , , ' ., � M PIPE TO EXISTING 3/4" " ' ' ' WATER PIPE. v v WCO ---- CD�i CONDENSATE DRAINAGE LINE _ P_2 uj uj EXISTING 3/4" COLD WATER IN, P-1 i o CTG CL.EANOUT TO GRADE �- 3„ FD 1 1 /2" @ 1/4" FT ACOCLEAN OUT : 3 -3 FU I ui �t 3" FD: FLOOR DRAIN WITH NCO WALL C :EANOLTT 319 @ 1/8 / FT.- 4 FU NIKALOY TOP, AND PRIMER tD N 4"-9 FU TAP FOR FLOOR DRAIN ° _...---. P-2 c FDM FLOOR DRAIN TRAP RESEAL. O w M M z Q / / ,,,� 3 1 8„ FT. - 3 FU w � ------ --•_ COLD WATER . t C . by . � L I NEE 4 � 1/8 / FT. - 6 FU w o 0 HOT WATER ( H, V . LINE 4„ _ 9 FLI z - CTG ) .�° ,,i, ,. . o Q PT -”- . PRESS . � 'TEMP . RELIES LINE TWO WAY ._ �. _- � ,�'_.' � �`;.:`_ � � �" 4" CO SEAL GATE VALVE WATER SUPPLY PLAN CHECK VALVE - SCALE 1/4 = 17-0 4" -i 9 FU p EXISTING 4 SAN. PIPE NOTES: 4" CTG (TWO WAY) 4" CO _ 1. INSTALL 1/2" C.W. AT RIGHT SIDE OF FIXTURE. SAIKJITARY ISOMETRIC DIAGRAIVI4„ RE TE • RELIEF VALVE 2. RUN 1 1/2" PIPE 0 1/4"/FT. FIXTURE ARM. 3. RUN 2" PIPE 0 1/4"/FT. N.T.S. - V 4. RUN 3" PIPE ® 1/8"/FT. � LN I ON 5. RUN 4" PIPE 0 1/8"/FT. 4„ 9 FU .... ENGINEERS HB HOSE BIBS f y CONNECT NEW 4" SANITARY _ PIPE TO EXISTING 4" b8 VACUUM BREAKER 3/4" S SANITARY PIPE. . F y, UT EXISTING 4 SAN. PIPE v i v VALVE IN VERTICAL � y . VTR VENT THRU ROOF NEW 3/4" REVISIONS: kiSTINc 3/4a � pFySHu T AFF ABOVE FINISHED FLOOR LEVEL 3/4� cw A�yE W N O FE FIRE EXTINGUISHER ON WALL BRACKET ( 2A- 208C ) NEW 3/4P-1 4"-9 FU � Cyy FEC FIRE EXTINGUISHER IN CABINET ( 2A- 10BC ) P-2 PARTIAL WATER PIPING ISOMETRIC FCC FLOOR CLEAN OUT PARTIAL (N.T.S.) 1/4" kO cq NEW 4" 0 EXISTING 4" SANITARY PIPE (D M EXISTING CO. Z . KUNMING GENERAL O ° o N � � Q P w LUMBING FIXTURE CONNECTION SCHEDULE i w tn CD q Do � 1 . THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT No. DESCRIPTION DRAIN WATER SLOPE REMARKS FU EXISTING 4" SANITARY PIPE �? 7 0 o ` p ., �, W NECESSARY FOR THE INSTALLATION OF A COMPLETE PLUMBING SYSTEM l=' COLD HOT NEW 4" CO. � � � z � ACCORDANCE WITH THESE DRAWINGS, THE APPLICABLE EDITION OF THE E : 'N, V P-1 WATER CLOSET 4" 1/2" N/A 3"&4-@1/8"/FT'. HANDICAPPED-18"H 4 W •i SOUTH FLORIDA BUILDING CODE, ALL OTHER APPLICABLE STATE, COUNTY uj L I � AND LOCAL CODES AND ORDINANCES. P-2 LAVATORY 1-1/2" 1/2" N/A 1-1/2"t�1/4"/FT. HANDICAPPED-34"H 2 CONNECT NEW 4" SANITARY EXISTING 4" SANITARY PIPE 2. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND PIPE TO EXISTING 4" '' Q ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS SANITARY PIPE c WORK. UPON FINAL ACCEPTANCE, A CERTIFICATE FROM THE LOCAL PLUMBING PLAN INSPECTION AUTHORITY SHALL BE FURNISHED TO THE OWNER. SCALE 1/4" = 1'-0" - O V ' 3. ALL MATERIALS AND EQUIPMENTS SHALL BE NEW, OF U.S. MANUFACTURER AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE, AND MUST BE ® ® w FURNISHED SO AS TO PREVENT ANY DEALAY IN THE PROGRESS OF THE o WORK. ALL WORK, THROUGHOUT SHALL BE PERFORMED IN A WORKMAN-- ka LIKE MANNER BY SUFFICIENT NUMBER OF SKILLED WORKMEN. 4. CONTRACTOR SHALL VISIT THE SITE AND REVIEW ALL PERTINENT UTILITY , DRAWINGS TO FAMILIARIZE HIMSELF WITH THE LOCATION OF ALL EXISTING w �1? AND/OR PROPOSED UTILITY STUB OUTS, PIPING, EQUIPMENT, ETC., AND Q BY W w MAKE DUE. ALLOWANCES FOR ANY CONDITION AFFECTING HIS WORK, APPROVED O MIAMI-DADE COLUN Y FIRE DEPARTIMEN'T I-- f- 5. ALL UNDERGROUND SANITARY & STORM DRAINAGE PIPING AND FITTINGS � � � p SHALL BE PVC-DWV (ASTM D-2662/0-3034). _ Mfi.LLDG. P9,l_mIT ON SITE -0 LL WATMR Iii Vl'EINSION LLJ i' 6, ALL ABOVE GROUND SANITARY & STORM DRAINAGE BRANCH & VENT ®.•;`�= 6 ���� �-- X � PIPES AND FITTINGS SHALL BE PVC-DWV (ASTM D-2662/0-3034). : , 7. ALL UNDERGROUND WATER PIPING SHALL BE COPPER TYPE "K" ASTM V) Q ~` B-306). ALL ABOVE GROUND PIPING SHALL BE COPPER TYPE 'L° z o w (ASTM B-306). z Lo u r 8. ALL HOT WATER PRESSURE AND TEMPERATURE RELIEF PIPING SHALL BE F EXHAUST FAN COPPER TYPE "K" (ASTM B-306). GRILLE 9. Q PVC (ASTM ' EXCEPT WHEN INSTALLED IN RETURN AIR PLENUM TIE TO EXISTING WHERE eePPER TYPE " " OR EQ6IPv0J=ENT MUST 13E USED. CIRCUIT. DRAWING TITLE ; 10. � ALL PLUMBING FIXTURES SHALL BE PROVIDED WITH ALL NECESSARY 8'-0" CEILING HEIGHT C2 IF L O O R"' ACCESSORIES SUCH AS STOP VALVES, "P" TRAPS, SUPPORTS, P & T P LA N VALVES, ETC., AS REQUIRED. ALL EXPOSED PIPING AT FIXTURES AND EQUIPMENT SHALL BE CHROME PLATED BRASS PIPE OR TUBE. PROVIDE SHUT OFF VALVES AND UNIONS TO ALL FIXTURES, ETC., REQUIRING WATER SUPPLY. PROVIDE DIELECTRIC COUPLINGS AS REQUIRED. FOR ALL COPPER PIPING CONTRACTOR MUST USE 95/5 SOLDER. PROVIDE AR CHAMBERS TO EACH FIXTURE AS REQUIRED. .- 11 . PROVIDE CLEANOUTS (WITH CHROME PLATED WALL OR FLOOR ACCESS DATE: FRAMES AND COVERS AS REQUIRED) AT THE BASE OF ALL WASTE 2/1/00 AND/OR VENT STACKS. PROVIDE PITCH PANS & LEADS FLASHING FOR DRAWN BY: ALL SANITARY SYSTEM VENTS. JULIO A. CHECKED BY: 12. ALL HORIZONTAL WASTE PIPING SHALL BE SLOPPED AT 1/8 PER FOOT, LIGHTING PLAN DIVISION UNLESS OTHERWISE NOTED. SCALE 1/4" = 1'-0" MIAMI LOCATION NO. 285 W.D. GUIDE PLAN r' t Ar PROJECT NO. DRAWING N0.E-' OF 7 SHEET NO. 3 OF 3