Loading...
00-0076-006 Qc copyright Peter Marich Architect EXIST. 1"OCWP T 3/4' THICK CMIN.> TEMPERATURE AND SERVICE TO BE RELIEF VALVE REVISIONS BUILDING & DISCHARGE , 1 2'OHW PIPE T❑ OUTSIDE ❑F PRES 1 2"OVTR REUSED / GAP 6' ABOVE GRADE J 1 1„� 6E --------------- ^�\, 1 IST TO ------ ----- ---'--- -- - --- /' .\ E� VIGE —SHUT-OFF I -----------D4 �I.Sn \ I �.\ 1 SER�SED UNION VALVE HEAT TRAP PER ENERGY CODE UNI❑N H.S EWH IN TOP I i 0 `\�`\ ,'��V� 2"0 1"O HOSE `-', OF MEZZANINE � G� `� ` , ELECTRICAL (2170) EXIST 6"0 /�� FGT R \,�- ¢ '3� JUNCTION BOX I ® 1/4 SLOPE 1 2„�V GREASE LINE 0 \ IRE \, I 2"0 PVC 3 COMP I TO BE REUSED D \- \, I ELECT, ®1/4" SLOPE I.W SINK I�, "' - I IPPWELL CONNECT( 3"0 4FU - \ HOT WATER J CONN. rr ( ) 3"0(6170) I 0 4 0 FCO I v) \ 4 SUPPLY LINE o I � 3 \ 3„0(8.5170) i V � EMBLEM AND � 2°re I I DSN j RATING PLATE Ili 10 V 2"OV S•S O 4"0(16.5FU) I FCD z' IL --- -/-/'/\'\ ELECTRICAL "'0 „ „QR ACCESS PANELS F o c� I I �; w FOR /' DRIP DROP 0, j. ��' 1 WATER HEATER I DRAIN VALVE DIRECTORS L 3"OVTR I I EXISTING BUILDING z QUIP PAN (OMIT ❑N HOSE W/114 O.W WC WC I I GREASE TRAP o/ / \, '�\ ,�/�•l' i 316� GROUND FLR.) C❑NNECTI❑N DRIP ® EACH. 3 r�FD I I GALLUCAP 1500 O U- "'0' nl, n �\ \,,\/.;/, 1 "0(00..5FU) I I I w C @ n V�G ` II EWC RUN IN SLOPE I I U WALL PAN DRAIN • I I I Q d, PARALLEL TO (f� P&T RELIEF L____J EXIST. 6"0 SANITARY ILATERAL TO BE REUSED. Z HOT WATER HEATER DETAIL N.T.S. Q I w WATER RISER DIAGRAM. N.T.S. N.T.S SHALL BE "A.O. SMITH" OR APPROVED EQUAL MODEL No. ESS-40 0 WITH 40 GALLONS STORAGE TANKS, DUAL NON-CONCURRENT 4.5 kw. z\ � ELEMENTS AT 240 VOLTS, WITH A 44 G.P.H. DRAW AND 14 G.P.H. RECOVERY AT 100 DE. TEMP RISE WITH AN ENERGY EFFICIENCY OF 0.89 MINIMUM I �\ .L LIJ pv \ \ W CD PLUMBING o v PLUMBING FLOOR PLAN z \ SCALE 1 1 4" = l'-O" \ 2"Ov W U OJ OJfR 0 � LL Rr ECG J L OgFAi,I, Vs�$ \ V TO Sy STE� z m Q GOT Roo I� I I 2 05E � U � R GP GENERAL PLUMBING NOTES J _ \ 1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE,, FEDERAL 7. PROVIDE MEANS 'FURNISH AND INSTALL". � ORDINANCES AND BUILDING CODES GOVERNING THE FIXTURE CONNECTION SCHEDULE F— N p 2 F r INSTALLATION OF THE PLUMBING SYSTEM. IF WORK AS LAID 8. DO A COMPLETE JOB EVERYTHING CONNECTED READY FOR USE. Z QT o(8' OUT, INDICATED OR SPECIFIED IS (CONTRARY TO OR CONFLICTS — U) �'� G I WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS, 9. SHOP DRAWINGS: CONTRACTOR SHALL FURNISH THE ENGINEER WATER 3 3 THE CONTRACTOR SHALL REPORT IN WRITING TO THE WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE ITEM WASTE & 3 D /SEAS~ ARCHITECT/ENGINEER BEFORE SUBMITTING A BID. THE FOR APPROVAL. SOIL COLD HOT OF,, RE �� HITECT/ENGINEER WILL THEN ISSUE INSTRUCTIONS AS 1�2 ��� HOW TO PROCEED. 10. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL WATER CLOSET 3” 1/2" - - �Ty �JG 3 GIVE THE OWNER AN AS-BUILT SET OF REPRODUCIBLE SEPIAS h 2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT SHOWING THE EXACT LOCATION OF ALL INSTALLATIONS. FLOOR DRAINS 3" 112" IVY 16'S�U) MINOR ITEMS. SHOWING UNLESS SPECIFIC LDIMENS DIMENSIONS SCALE ALL OF THE � �� ` �( 1 NS ARE SHOWN, THE 11. PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS LAVATORY 1-1/4” 112 112 It`d k STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL REQUIRED BY CODE. TEST SHALL BE WITNESSED AND APPROVED 4 G 3" _ GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW BY PROPER AUTHORITIES. KITCHEN SINK 1-1/2" 112" 112” � I• T SFU) DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL GO i ''�� TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED 3 GO 12. THE PLUMBING CONTRACTOR SHALL WARRANT ALL DISHWASHER 1" hose - - 1/2" v F AND MAINTAIN MAXIMUM HEAD ROOM, AND SPACE CONDITIONS WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE v 3''O AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDITIONS OF FINAL WORK ACCEPTANCE BY OWNER. ANY BREAKDOWN APPEAR INADEQUATE, ARCHITECT/ ENGINEER SHALL BE OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE -_� 'p / NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS TO THE OWNER. H SANITARY RISER DIAGRAM. ,QED // CONTRACTOR O TRACT ON HALL, WITHOUT T NEEDED CHARGE, CONFLICT I ; ' N.T.S PREVENT/ WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION 13. PROVIDE BATHROOM FIXTURES AS SPECIFIED. WATER PIPING SIZE I. ; CO OF THE WORK O � k, 8 'Y 14. PROVIDE SHUT-OFF VALVE FOR EACH FIXTURE. (D 1 12"0 C W/I I W ` Lo Q1/2"0 C O M ITARy 3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. 15. WHEREVER NOT SIMILAR METALS ARE TO BE JOINED, A DI-ELECTRIC 314"0 CW 1112"0 I1W �� i t j 0 d V Z SA M IJ CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND/OR FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. C t; _ Q �0 CONNECT WITH APPROPRIATE SERVICES ALL PLUMBING ITEMS H) V4"0 W/HW 6 SHOWN ON ANY OF THE ARCHITECTURAL, AIR CONDITIONING, 16. PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING D 3/4"0 1IW ;N[�' Q) Q ,��R E�(IST' ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL CONDENSATE DRAIN AND TRAP. SEE AIR CONDITIONING PLANS © 314"0 C W �I' � ��'�I fi �2 SEER EXPENSE TO THE OWNER. IF DISCREPANCIES CONFLICTS FOR LOCATION OF UNITS AND DRAINS. Q 1"0 CW ( ::>y- ! LI I I ,. [ W J� � INTERFERENCE OR OMISSIONS OCCUR BETWEEN DRAWINGS, > O NOTIFY IN WRITING THE ARCHITECT/ ENGINEER IN AMPLE TIME 17. MATERIALS N TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED. A. COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE 9.,.1 Cr) e Q V- O , TYPE 'L COPPER BELOW GROUND AND TYPE "M" COPPER ABOVE GROUND. ( •„y Z d' 4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST B. COLD WATER PIPES INSIDE OF SLAB SHALL BE TYPE "K” SOFT COPPER J N CLASS WORKMANLIKE MANNER. THE OWNER RESERVES THE INSTALL INSIDE POLYETHYLENE CONDUIT. NO JOINTS PERMITTED INSIDE SLAB. 1V1'4 RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH, C. SANITARY WASTE AND VENT 4"0 AND SMALLER SHALL BE P.V.C., SCHEDULE 40 N 0 T E: ("."J ; W IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE S. STORM LINES INSIDE BUILDING SHALL BE P.V.C. SCHEDULE 40 Ali SANITARY PIPE "0 OR SMAII FR W APPEARANCE. REMOVAL AND REPLACEMENT 1S TO BE DONE IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT E. IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF BUILDING SHALL RUN © 114" SLOPE PER L.FT. J I THE SOLE EXPENSE OF CONTRACTOR. SHALL BE SCHEDULE 40, PVC. 3" AND LARGER © 118" SLOPE PER LET. F i �°�' _ �/ ti 2��� F. CONDENSATE DRAIN PIPE SHALL BE SCHEDULE 40, TI PVC PIPE AND FITTINGS. U (f) Q G . START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS G. WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE "L- COPPER, MIN 314 DIA. °�-- > ,_..!: n/ C) W J \ ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO °" n....= LL _ _j W ~ SUITABILITY OF THE WORK OF OTHER. TRADES OR OTHER a �ZFU) CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR FIRE RATED PENETA I w 2 SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL PLUMBING RATION NOTE Z WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF WHEN P.V.C. IS USED PROVIDE PRO-SE7" AND PATCH �+ INTERFERENCE WITH OTHER TRADES. UP OPENING WITH FIRE RATED SEALER SMILILAR TO "3M" t. "O C-128 OR APPEOVED EQUAL a 2"Ov 6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, �5�� U U� I DVS FEES, PERMITS , ASSOCIATION DUES, ROYALTIES AND TAXES OF 1101`0 RE a�(qF F WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO PAID ALL THE INSPECTION FEES AS MAY REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM/ I Y QSE DAMAGE AND EXPENSE ARISING FROM ANY OLATION OF LAWS, V FLORIDA REG. #4742 RULES OR ORDINANCES. aa qt 33 $if dE�TTARy \ \—� 2 5PNi ;OO IW O 5YSTE"" llz'� I ` GOT • ELECTRICAL (n • MECHANICAL r/r'I • PLUMBING 5.5 , �`rv� wo CARL❑S M. P_ w W W4 9ARRENECHEA PRESIDENT GREASE LINE RISER DIAGRAM. T Z° GQ o MIAMI, FLA. F'I` rGQ _IL 4936A S.W. 74 CT. �n V/ f SHEET: ` O� � [I]� 331 55 N.T.S Z � (�QF Iy to F t�U,c>Ili ZZ OFFICE �"� // Ca-� ���( ,II W (3 05) 665-7759 / SSE �•.'. FAx / R • (305) 665-7755 G ? �B ERIE �F a'' L.C. NO. EB 0007150 OF I,IN P.E. N❑. 0053288 „„r Y•� JOSE A. MENDEZ ��•• FL l • MECHANICAL ENDINEER DATE: 0 � 3