Loading...
00-0076-004 copyright Peter Marich Architect STANnARn 3" WInF IIANGFRS REVISIONS •.:. Hongel extension to be the sure of the distances between thq;,, hanging wires and the duct size, IU �fSrnacna) J Maximum Hanger nur.t size, Inches Maximum 48: Wide or grater 4 H less tho 48" wide Eft and less thon 48" deep Width between 28" Eft / Em & 48" and greater ile �; than 16" deep „ R�It� /I Odor thgn 29" wide 8ft C OR and 16 depth or less EXISTING TO BE REVISED FAN-COIL \ ° 26x6SR C HANNEL SECTION o y DESOWM CFM MBNH ENIERINO F Emnam DATA REF OBS 455 CFM ° TOTAL SENSIBLE VM 0 VOLTS MMM smut 0 FUSES UMILIFAC. UWr LIM Sue. COND. CU IN ROOF F local Channel Channel t PPWELLCANNECTI°NS EXISTING TO BE c�•d..���� 8x6CD-1 W REUSED Fxtan;;ian is Channel AH1/ 1200 � 24.a 80 e7 240 1 a � 30 A-ae-V 150 CFM riot greater than: Gauge Profile o x W 6 >4 3" X 1.5" CONDENSING UNIT cv Z e 18" 22 S" X 2" MF. ENT. ELECI14M DATA W. 00S on sm z 3 D" 18 3" X 2" DE516 7M MBTUH CONDENSER VDLTS PHASES 11MIREAMPS FUSES MANUFAM UW AREA SERVED LL USE OF 2" WIDE CU 34 ea 240 1 21.8 M 4W MM CK"-1/1A 10.2 SHM 0 W-41 LL 22 gauge 2'x 1.s hangers snag be substituted HANGERS AND SUPPORTS for 3" hangers for ducts with widths not over 48" 1,1J and depths not over 24" provided that not more 6"OG.M.D.(26GA) () than one joint occurs between hangers and the \ ] THRU WALL W/WP Q maximum hanger spacing 4ft. Exception: When 26x6SR -, EF-1 E 1 CAP, B.D.D. AND INSECT duct perimeter is 80" or less and does not 455 CFM SCREEN require reinforcement two joints are permitted between hangers 20x10 z CO V EXISTING AHU TO Q BE REUSED. `Z LEGEND GENERAL H.V.A.C. NOTES 6"0 tCO�M W 1. The contractor shall furnish all labor, material and equipment for a complete H.V.A.C. system in accordance with these drawings. .A.1. Z The Sauth Floridn Ruilding Code and the latest edition of the 6x6CD-1W CEILING GRILLE SEE SIZE SCHEDULE following publications: 24x24 CFM 70 CFM DUCT TO MATCH NECK Sl_7E TYP. (a ANS R9.1 Mechanical Refrigeration (h) NFPA Pamphlets 9OA �4r. 91 RAG 24X48 RAG-( SEE SCHEDULE) (c) SMACNA (d) ASHHAL. W/FIL �THERMOSTAT 2. All air conditioning ductwork shall be 1 1/2 " standard duty w O - foil reinforced fiberglass (R 6) manufactured logo printed on the �" LU barrier. AIR FLOW DIRECTION ( AF'ROWS DENOTE vapor Q 1 WAY, 2 WAY, ETC., SEE` PLANS J. All exhaust ductwork shall be code gage galvanized sheet rectal. T Q RETURN OR EXHAUST, SEE PLANS. 4. Duct size shown are net free area inside. 0 Q Q 5. All air devices (diffusers, registers and grilles) shall be all FULL RETURN z h WALL MOUNTED SIDE REGISTER. alurninurn construction, wilh exposed urface chernicolly Irealed to PLENUM _I r , �J \ receive point to match color or AIRCUIDE or approved equal. 1J W v 0 \ 6. Provide opposed blade dampers at all diffusers and royisicrs. ,`�.-•� . �V 0 _J L�J EXHAUST FAN 7. Thermostats shall be combination cooling/heating with system PLUMBING FLOOR PLAN THIS UNIT IS EXISTING 0 Q - Cool/Auto/Heat/Off and Fan On/Aulo selector swilches TO REMAIN. NO CHANGE = 0.,4.1. OUTSIDE AIR INTAKE B. Refrigerant piping shall he capper type "I " with ,S/4" arm SCALE 1/4" 1'-0" IN AREA OR DESIGN W aflex. Q Insulation shall be provided for suction lines. Q S.R SIDE REGISTER 9. Provide new filters for fan coil before starting. These EF-1 SHALL BE "GROAN" 360 re fillers rnusl also be replaced prior to final acceptance by owner. 84 CFM, 0.25" SP., CEILING 0 co CEILING DIFFUSER MOUNTED BACKDRAFT DAMPER � U) � CD CEILING GRILLE BUILT IN. � W O U.0X UNLESS OTHERWISE NOTED. I� N OUTSIDE AIR CALCULATION (,f AS PER SEAT ALLOCATION J EMPLOYEES= 12 CHAIRS + 2 PERSONS 14 PERSONS ® 15 CFM PER PERSON =210 CFM ( V t 3 ;I ` t-! .� , i EXIST STEEL w :w .� 1 / JOIST CEILING ;a.� g� >r.y O AS REVD. I ~ 0 U M Z .. 3/16" PROVIDE W/ 4-112- THRU DUCTS SUPPORT AS PER BOLTS, PROVIDE ISOLATION SPRING AT F.C.U. WITH SMACNA STANDARDS I � Q W O NUTS & WASHER AT W4 x 13 FASTENED G.U. TO STEEL W/ 4-3/01? I > 0 t I ; N FILTER RACK A B. (ONE AT EACH SUPPORT) AND T , ' -9 _� r; LL BOTTOM CORD OF STEEL , AND ACCESS JOIST. PROVIDE SOLID ISOLATION PAD _- „ �8, `� # ~ z o N FOR CORROTION INIVITER (TO - �•_.. v F.C.U., SEE PLA WITHSTAND 125 MPH WIND) W 0 W FAN ACCESS COIL ACCESS �t 2"- PIPE U U) Q ~ W _l PANEL PANEL W4 x 13 PLATE 1/2„ O J W Q i— 2"0 PIPE RETURN AIR GRILLE, SEE PLAN 2 -3/4"0 THRU BOLTS W/ NUUTS & WASHERS COND. DRAIN PIPE SIZE AS PER UNIT CONECTION REQUIRED, 3/16- FLORIDA REG. #4742 OUTSIDE AIR SEE SCHEDULE. " INTAKE WITH 2 -3 4 0 THRU BO S DAMPER W/ NUTS & WASHERS AUXILIARY DRAIN PAN WITH 314" PVC PIPE TO DISCHARGE ON VISIBLE FAN COIL MOUNTING DETAIL LOCATION C O ND . UNIT S UP P O RT D E TAIL • ELECTRICAL cn • MECHANICAL N.T.S. N.T.S. a,° • PLUMBING I w W CARLOS M. Wp BARRENECHEA PRESIDENT Zo —� 4936A S.W. 74 CT. MIAMI, FLA. In. 33155 SHEET; '� '`. � Z OFFICE A (305) 665-7759 HVAf nF SIGN HF OUIRMF N I S y!­S NO W FAx OUL I "11'MOKF nF IFC IOH X (305) 665-7758 ' 1 1121 I.; MPI /?(S) X r SMOK DAMPERS X OF1 + 1 ; FIRF TFn FNCI OSURF X L.C. Na. EE300071 50 r FIHE R�IL.D HOOF X P.E. No. 0053288 F I OOR C F II I N Y X G ASSF MH I •' r•�/ r + X JOSE A. MENDEZ DATE. 0 �..`• t�l 0 p FIHF Sit OPPING `'/`•-, . SMOKE CONTROI X MECHANICAL ENGINEER