00-0076-002 copyright ' ELECTRICAL NOTES 0_ _, , , Peter IUarich architect +16" A.F.F. 1. ALL WIRING RUNS EXPOSED, CONCEALED IN MASONRY WALLS OR CONCRETE 13. SEE EQUIPMENT LAYOUT PLANS FOR EXACT LOCATION OF ALL MOTORS A D ' J 16,18 SLABS, BENEATH SLABS OF GRADE OR RUN UNDERGROUND SHALL BE IN RIGID OTHER EQUIPMENT BEFORE ROUGHING-IN. ABOVE COUNTER GALVANIZED STEEL CONDUIT. ELECTRICAL METALLIC TUBING MAY BE CONCEALED IN INTERIOR HOLLOW WALLS AND ABOVE SUSPENDED CEILINGS. 14. ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT IJO� FURN��Ilcl7 (TYPICAL) REVISIONS UNDER THIS SECTION BEFORE ROUGHING-IN. 2 . ALL WIRES SHALL BE COPPER UNLESS SPECIFICALLY OTHERWISE INDICATED ON s (' THE DRAWINGS. ALL INSULATION SHALL BE TYPE "THW". OR "THHN/THWN". 15. SEE EQUIPMENT LAYOUT PLANS FOR LOCATION OF BUILDING EQUIPMLN(' HEFORt 21 12(E) 1 1,13 ROUGHING-IN. 10 12(E) 10 Elf 12(E) 10 10 3 BOXES SHALL BE PROVIDED FOR ALL OUTLETS. !N GENERAL THESE BOXES SHALL BE STAMPED OR PRESSED SHEET METAL. BOXES IN HAZARDOUS AREAS SHALL BE 16. ELECTRICAL CONTRACTOR SHALL VERIFY LOCATION OF ALL EQUIPMENT'S 9 APPROVED FOR THE CONDITIONS INDICATED. REQUIRING ELECTRICAL CONNECTION BEFORE ROUGHING-IN. EHWH IN SOFFIT 4 ALL CONDUITS SHALL BE SECURELY FASTENED TO THE BUILDING WITH PIPE 17. CONDUIT RUNS ARE SHOWN SCHEMATICALLY. BUILDING CONDITIONS WILL 21 6,8 ABOVE STRAPS OR OTHER APPROVED PIPE SUPPORTS. DETERMINE THE ACTUAL CONDUIT RUN. (6 LAMPS) EXIST. ° SERVICE 5 MANUFACTURER'S NAMES AND CATALOG NUMBERS ARE USED TO DEFINE THE 18. ELECTRICAL CONTRACTOR SHALL VERIFY WITH MANUFACTURER THE LOCATION � DISTRIBUTION ' TYPE AND QUALITY OF EQUIPMENT AND MATERIAL. EQUAL ITEMS OF OTHER OF CONNECTION BOX OF EACH EQUIPMENT BEFORE ROUGHING-IN. ° MANUFACTURERS ARE ACCEPTABLE WITH THE APPROVAL OF THE ENGINEER. 19. WHERE WIRE SIZES ARE INDICATED ON THE PLANS FOR ANY INDIVIDUAL � OVERHEAD 6 ALL WORK SHALL BE DONE IN FULL ACCORDANCE WITH THE NATIONAL CIRCUITS. THE INDICATED WIRE SIZE SHALL APPLY TO THE COMPLETE 021 __ ..____--, SERVICE ELECTRICAL CODE ALL APPLICABLE STATE AND LOCAL CODES, AND THE LOCAL CIRCUIT UNLESS OTHERWISE INDICATED. JB'S FOR SIGNS 24X24 UTILITY COMPANY REQUIREMENTS. THERE ARE EXISTING 17 24 i24X24S o 20. ALL MOTORS STARTERS FOR FANS, PUMPS, BOILERS, AIR CONDITIONING, ETC.; MAKE ALL FINAL I PANEL ❑ IMPACTA W12-22 WATTS 7 ALL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. SHALL BE EQUIPPED WITH OVERLOAD PROTECTION IN EACH PHASE LEG. CONNECTIONS AS LAMPS (TYPICAL) STARTERS FOR MOTORS RATED AT 50 HP. OR LESS AT 208 v. MAY BE ACROSS THE REQUIRED -NEW ELECT. PNL 8 AS SOON AS PRACTICABLE, AND WITHIN THIRTY DAYS AFTER THE AWARD OF THE LINE TYPE, WHERE APPLICABLE STARTERS FOR LARGER MOTORS SHALL BE TYP. FOR 2. CONTRACT, AND BEFORE ANY MATERIALS OR EQUIPMENT ARE RELEASED FOR REDUCED VOLTAGE TYPE PART WINDING, PRIMARY RESISTOR, ETC.) (7 LAMPS) EXIST. O O 2 SHIPMENT, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR APPROVAL A 022 Q COMPLETE LIST OF MATERIALS AND EQUIPMENT THAT HE PROPOSES TO FURNISH 21. ALL EQUIPMENT FURNISHED WITH CORD, THE CORD SHALL BE SHORTENED AND 20 r0 r� W AND INSTALL, GIVING MANUFACTURER'S NAMES. TRADE NAMES, CATALOG INSTALLED WITH CORRECT OUTLET PLUG, JACKS, ETC., AS REQUIRED FOR J NUMBERS, ETC. SEVEN COPIES SHALL BE FURNISHED. COMPLETE INSTALLATION OF EQUIPMENT. ALSO WHEN APPLICABLE RECEPTACLES W EXIST. LIGHTS W 112W L.V. 2 21 z SHALL BE FURNISHED TO MATCH THE ELECTRICAL EQUIPMENT SERVED BY. LAMPS(27 TOTAL) 15 9 WHERE A CONDUIT PASSES THROUGH A BUILDING EXPANSION JOINT OR A N TYP. U.O.N. 21 CU ON STRAIGHT RUN EXCEEDS 200 FT AND APPROVED EXPANSION FITTING WITH 22. ALL ELECTRICAL SERVICE EQUIPMENT SHALL BE READILY ACCESSIBLE c ROOF BONDING JUMPER SHALL BE INSTALLED. AND SHALL HAVE CLEAN AND DRY LOCATION AND BE PROTECTED FROM PHYSICAL 23 0 DAMAGE: ALSO, CLEAN WORKING SPACE SHALL BE PROVIDED AROUND EQUIPMENT .� N A 3R D.S. SIZER LL1 LL 10. WHERE FUSIBLE EQUIPMENT IS SPECIFIED,DELIVER TO THE OWNERS AS PER NEC. 110-16 (a)(b). EXIST. 150W REPRESENTATIVE SPARE FUSES IN THE AMOUNT OF 10 9 OF EACH SIZE USED ON SPOT H.H. .4 : w A P R EQUIPMENT w THE JOB WITH A MINIMUM OF 3 FUSES OF EACH SIZE 23. JUNCTION AND PULLBOXES SHALL BE SECURELY MOUNTED TO THE BUILDING STRUC. (9 LAMPS) EXIST. N TE & TO Q WITH SUPPORTING FACILITIES INDEPENDENT OF THE CONDUITS ENTERING OR LEAVING THE 021 C LY•:' NEC 110=16 a 11. THE CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING HIS BID IN ORDER BOXES. BRACKETS, RODS, HANGERS, BOLTS OF OTHER SUITABLE SUPPORTING METHOD M THAT HE MAY BECOME AWARE OF EXISTING CONDITIONS, NO ALLOWANCES WILL MAY BE USED. AHU IN - U) BE MADE FOR ANY EXISTING CONDITION OF WHICH THIS CONTRACTOR WAS NOT SOFFIT AWARE r��t�. SPACE z 24. JUNCTION AND PULLBOXES SHALL BE GALVANIZED CODE-GAUGE SHEET STEEL, WITH SCREWED ON COVER, NEMA 1, OF SIZES AND SHAPE TO ACCOMMO 1 3 12. CIRCUIT NUMBERS SHOWN ARE FOR IDENTIFICATION ONLY. IT SHALL BE THE WIRING WITHOUT CROWDING AND TO SUIT LOCATION. (g ��/�®� (+ �p ' PHOTOCELL z ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO COMPLETE PHASE PANEL BOARD 1 v L 9- 21 CONTROLLED W (BALANCE LOAD). 25. ALL JUNCTION AND PULLBOXES SHALL BE ACCESSIBLE ALL THE TIME. F"2-A"' ,. y 26. ALL RACEWAYS ROUTED, INSULATED CONDUCTORS SYSTEM SHALL BE COL )R 14(E) 14(E) 21 14 E 21 ' ` C� CODED AS PER NEC. STANDARDS e p� {� . � : ( ) z 11MIAX. 75' OF TRAVEL.. °I OP OF F= 15 A) co E TiNGUeSHIE NOT TO EXCEED (E) DEN07 w 5 FT. ABOVE FLobR TO REUSED.G I- W ` ELECTRICAL FLOOR PLAN LL Q SCALE 114" z J TYPE: LOADCENTER CUTLER-HAMMER PRLIa OR EQUAL MAIN BUS: 225 A EX<S r -• SERVICE: GELATO CAFE NEUTRAL: 225 A VOLT4C =: 120/240V,1 PH, 3W PANEL MAIN-s LUGS ELECTRICAL FIXTURE LEGEND S PI tct r B a->` • U- MOUNTINC-FLUSH 1 IC: 22,000 A O JUNCTION BOX � W � 1 O CEILING OUTLET IINF.P.L. O W.PRCAP < } REMARKS REMARKS i kI �� 'o WALL OUTLET I� !� Q 8 8. m 'p �' DUPLEX RECEPTACLE ( +18" A.F.F. 3#3/0 Cu THWN ) IN 2 COND. O 30 2 5575 112 10 AHU # 1 QUADRUPLEX RECEPTACLE ( +18" A.F.F.) NEC 310-16 `" _ 1 2 CU#1 10 1/2 3800 2 30 3#3 0 Cu THWN IN y I;' ,' ,' y � 3 4 N•C GROUND FAULT 2 COND. t 20 1 850 112 12 ICE FREEZER 5 6 � INTERRUPTER LV m NEC 310-16 i5t``sa� . `� -,pG.i `r6a 1 ,% nu ' 20 1 850 1 2 12 7 e EHWH 10 1/2 4500 2 30 200 A NEMA 3R METER NLSURE. ~ O 1'� di��3�.St'au Z � O / " U1P WEATHER PROOF it i 20 1 180 112 12 CASH REGISTER 9 10 ® ELECTRICAL PANEL RECEPTACLES 12 1/2 1080 1 20 "•- • ,.E' n;t,' .....� -• li 12 RECEPTACLES PNL X��IATE r.t 0 M'?, 'I�'' 35 2 6000 112 ,t0' DISHWASHER 12 1/2 540 1 20 Lo DISCONNECT SWITCH SAT_t-� J^ r 1 ^^ E - � 13 14 RECEPTACLES 12 112 900 1 20 20 1 1500 112 12 LIGHTING 13 16 i ' EXHAUST FAN #4 Cu THWN 20 1 1500 1/2 12 LIGHTING 17 18 COFFEE MACH. 10 112 4500 2 30 $ TOGGLE SWITCH f IN 112" COND. 200A, 120124OV, 10 NEC 250-94 20 1 1500 112 12 LIGHTING 19 2G SIGN INT. 12 112 1500 1 20 3W 3 WAY TOGGLE SWITCH N3R, 22,000 A C W. pIPE-� MAIN CKT. BKR CUTLER �k 1 650 1/2 12 EXTERIOR LTS 2! 2c SIGN EXT. 12 1 12 1500 1 20 �k HAMMER ED OR EQUAL.. 20 1 720 112 12 DRINKING FOUNTAIN 23 24 RECEPTACLES 12 1/2 360 1 2p HOME RUN - - - - - SPACE ES 26 SPACE - - - - - © TELEPHONE OUTLET ( +18" A.F.F.) %%,` ' j `«l ij i i {,� \ %//jam �% / / ` \ \\ ` - - - - - SPACE 27 28 SPACE - - i ,_" -, .. . O�Oj� / � 240 V., 3 POLE FEMALE RECEPTACLE - - - - SPACE 29 30 SPACE - - - COORDINATE WITH OWNER FOR TYPE 518"X10' GROUNDING TO STRUCTURAL FOUNDATION ROD EXIST. CONNECTED LOAD: 34205 VA FEEDER'- 3#3/0 THWN CU 2" CON. T.� EMERGENCY LIGHT WITH BATTERY BACK UP AS PER NEC 250-81(c) IW- O-I EMERGENCY EXIT LIGHT WITH BATTERY BACK UP O � CONTINOUS LOAD: 8150 VA `-TM � J$$ d � Gam;-_� k..�p l LL LO 259 CONT. LOAD: 2038 VA r NON. CONT.LOAD: 26055 VA ELECTRICAL RISER DIAGRAM L Ij 1 t ° M TOTAL 36 243 VA -� S' �� Z FED FROM FPL SERVICE �� F f 36243 AMP= 240 = 151 AMP *DENOTE CONTROLLED BY TIME CLOCK I I t. �k �k THRU PHOTOCELL. em­' I H' Q 0 N Z LL N PANEL BOARD & LOADCENTER NOTES SITE INVESTIGATION NOTE r ';-; � W` ' � za r 1. ALL PANEL ENCLOSURES SHALL BE LABELED WITH LAMINATED BAKELITE HAVING BLACK LETTERS EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK: THE BIDDER IS REQUIRED BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND ' Z _J N ON WHITE BACKGROUND. LABEL SHALL SAY WHERE IT IS FED FROM AND EMERGENCY BRANCH (WHERE FAMILIARIZE HIM OR HERSELF WITH THE NATURE AND EXTENT OF THE WORK AND U Q APPLICABLE), m ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE 2. PROVIDE ALL PANELS WITH COPPER BUS BAR. AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES W LL o O J w NEW AND/OR EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION SHALL Q �, U 3. ALL PANEL LOADS ARE BASED IN VOLT-AMPERES EXCEPT AS OTHERWISE INDICATED. BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, NEW FACILITIES AND ALL BUILDING STRUCTURES FAMILIARIZE TO HIMSELF WITH ALL EXISTING CONDITIONS. SLIGHT VARIATION " 4. ALL CIRCUIT BREAKERS & DISCONNECT SWITCHES SHALL BE LABELED WITH LAMINATED BAKELITE OF ROUTING AND OR CONSTRUCTIONS SHOULD BE ANTICIPATED BY THIS CONTRACTOR TO AVOID HAVING BLACK LETTERS ON WHITE BACKGROUND. LABEL SHALL SAY WHERE IT IS FED FROM, WHAT IT IS CONFLICTS WITH OTHER TRADES. THESE VARIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART SERVING, AND EMERGENCY BRANCH (WHERE APPLICABLE). OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITY 5. ALL PANEL DIRECTORIES SHALL BE TYPEWRITTEN DESCRIBING ALL CIRCUITS, AS SHOWN ON PANEL ASSUMED UNDER THIS CONTRACT. SCHEDULES. 6. CIRCUIT DIRECTORY HOLDERS SHALL BE METAL FRAMES WELDED TO THE INSIDE OF EACH CABINET DOOR AND HAVE TRANSPARENT COVER UNDER WHICH SHALL BE PLACED NEATLY TYPED SCHEDULES FLORIDA REG. #4742 OUTLINING CIRCUIT CONTROL. 7. STUP-UP 4-1" EC FROM EACH FLUSH MOUNTED PANELS INTO CEILING SPACE (ACCESSIBLE AT ALL TIMES) AND CAP FOR FUTURE USE. 8. ALL NEW BRANCH CIRCUIT BREAKERS SHALL MATCH EXISTING CONDUCTOR SIZE, IF CONDUCTOR SIZE IS LESS THAN CIRCUIT BREAKER SIZE, CHANGE CONDUCTOR TO MATCH CIRCUIT BREAKER. FOR EXISTING • ELECTRICAL MOTOR NOTIFY ENGINEER BEFORE ROUGHING-IN. IM N • MECHANICAL • PLUMBING 9. (Y o ALL PANEL BOARDS, CIRCUIT BREAKERS AND DISCONNECT SWITCHES SERVING EMERGENCY W� CARL❑S M. EQUIPMENT SHALL BE PAINTED RED, WHEN APPLICABLE. < BARRENECHEA 1 W PRESIDENT Z o 4936A S.W. 74 CT. o MIAMI, FLA. [9 331 55 jzzo FFICE SHEET: W (305) 665-7759 FAX (3135) 665-7758 E - 1 L.C. No. EB❑❑❑715❑ w� P.E. No. 0052023 OF1 �� 2 ��� k•= - EDUARDO MARTINEZ ISM • i a ELECTRICAL ENGINEER DATE: "����,•`• ��:,,134�(���;�