00-0046-026 _
GUT^BAZK TO FINISHED RELIEF LINE TO
ROUGH IN TO 6' ABOVE ^ GRADE & PROVIDE 4° EXTERIOR
PROPOSED FINISH GRADE THREADED BRASS CAP COLD WATER
-, & CAP yv`�v�, �I ^j�� 7/_ INLET w/VALVE � ISSUANCE FQR
}-
=
PLUMBING NOTES= FINISHED GRADE—=_\
,
PRESSURE TEMP. ❑BIDDING SET ONLY
RELIEF VALVE ❑CONSTRUCTION SET ONLY
1. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH, HOWEVER, NOT
LIMITED TO, THE 'LATEST EDITION' OF THE STANDARD BUILDING CODE (SB.C.C.L), THE Y/�//\/ /\\/\/\/ \/\/\/\/\/\/\ ❑BUILDING�PERMIT SET ONLY
STANDARD PLUMBING CODE,NPP.A., AS WELL AS ALL APPLICABLE NATIONAL, STATE 4 HEAT TRAP, PROVIDE F •., j
1" THICK INSULATION REVt 02�1YC100 •,:t
LOCAL CODES, REGULATIONS 4 ORDINANCES AND WITH THE FLORIDA ENERGY EFFICIENCY ( WHERE REQUIRED ) W REV2 '
CODE FOR BUILDING CONSTRUCTION. FLOW 91 REVS--,
2. THE CONTRACTOR SHALL FIELD VERIFY ALL INVERT ELEVATIONS AND SIZE OF EXISTING
SEWER AND WATER MAINS FOR CONNECTION OF NEW SERVICES. WATER HEATER
SEE PLAN FOR SIZE
3. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS OR
SHOCK ABSORBERS.
EXTERIOR 2° AY THERMOSTAT
CLEAN-OUT DETAIL ACCESS PANEL �
4. ALL PLUMBING FIXTURES SHALL BE DETERMINED BY OWNER � AFFIX SEAL HERE
5. ALL HORIZONTAL BUILDING DRAINAGE PIPING OF 2" DIAMETER AND LESS SHALL BE a ;
INSTALLED WITH A FALL OF NOT LESS THAN 1/4" PER FOOT.
/—WATER HEATER DRAIN
PANS SHALL COMPLY
6. ALL HORIZONTAL BUILDING DRAINAGE PIPING 3" DIAMETER AND LARGER SHALL BE WITH s.F.r3.c., SECT.
4614.18(c)(1), (2), (5), (6),
INSTALLED WITH A FALL OF NOT LESS THAN 1 18" PER FOOT UNLESS OTHERWISE NOTED ON (7) & 4614.19(f)(3).
THESE PLANS OR ELSEWHERE IN THESE NOTES.
1. PROVIDE FULLY ACCESSIBLE CLEAN OUTS ON SANITARY 4 WASTE PIPING AS SHOWN OR AS "LOW BOYS
REQUIRED BY CODE,
WATER HEATER DETAIL v N
6. VENT LINES SHALL EXTEND A MINIMUM OF 6 ABOVE THE ROOF AND SHALL BE FLASHED r
WITH A LEAD BOOT OR SHALL BE CONNECTED t0 OTHER VENT THRU LINES. N.T.S. O
2 tt COND
. THE PLUMBING CONTRACTOR SHALL SECURE ALL PERMITS AND PAY ANY 4 ALL FEES ( IF HB DISC. DRAIN
9 3/4" t4
APPLICABLE ) REQUIRED t0 PERFORM THEIR WORK 14J3 1"PAN DRAIN RELIEF DRAIN
10 W4 11 10. THESE DRAWINGS ONLY PROVIDE DESIGN LOCATIONS FOR THE EQUIPMENT DEPICTED 2" VTR
HEREIN, THE PLUMBING CONTRACTOR SHALL OBTAIN $HOP DRAWINGS / CUT SHEETS FROM \\ I I 4" w `�
THE EQUIPMENT SUPPLIER IN ORDER TO PLACE ROUGH-IN LINES AT OPTIMUM LOCATIONS E LAUNDRY
FOR THE SPECIFIED EQUIPMENT. \ Gala
1/2" I/2"CUl \ �otsc. W/14 w O w
11. THE TEMPERATURE OF MIXED WATER t0 INDIVIDUAL SHOWERS AND SHOWER / BATH g Q
COMBINATIONS SHALL BE CONTROLLED BY A SCALD PREVENTATIVE VALVE OF THE
ELECT.
PRESSURE BALANCING OR THERMOSTATIC OR COMBINATION MIXED VALVE TYPE. HANDLE m . .
POSITION SLOPS SHALL BE ADJUSTED IN ACCORDANCE WITH METER
MAIN 1 CW . . o W ✓-' �(
MANUFACTURERS INSTRUCTIONS At TIME OF INSTALLATION t0 A MAXIMUM MIX OUTLET DISC LEI s� m� ( �• FAMILY ROOM
TEMPERATURE OF 120 F. PER 5P.5.C. 4614.19(() ��� wW
13. THE PLUMBING CONTRACTOR SHALL PROVIDE FINAL CONNECTIONS TO ALL REQUIRED '
r---------
EQUIPMENT, UNLE55 OTHERWISE NOTED. NOOK
2l ` �•�i
WR W.I.C. i 1-1/2" LAV 2" JAC
14. THE PLUMBING CONTRACTOR SHALL COORDINATE w/LOCAL UTILITY COMPANIES t0 OBTAIN GARAGE I 3/4"CW d I I I O W
EXACT LOCATIONS OF ALL UNDERGROUND UTILITIES FOR THE SITE AND SHALL VERIFY l 13 14"HU(OVER I A
CW I `"
LOCATIONS PRIOR TO BEGINNING ROUGH-IN. CEILING) 3/4— — — 3/4"HW(OVER ( A
15. IN GENERAL, THESE PLANS ARE DIAGRAMMATIC ONLY AND SHOULD NOT BE SCALED. _ _ — — i_ --
71- -- - —.- -. -- • - - --- - .--.- - . — CEILING) MAST_ - - - - - - — A�'T „
COORDINATE ALL PLUMBING WORK WITH ELECTRICAL 4 H.V.A.C. WORK SO AS NOT TO - - - - I- �-� - - -/ - - - - - - - - - _ _ I_ _ _ _ _
CONFLICT IN LOCATION OR PERFORMANCE OF OTHER SYSTEMS. I // III I I i rl o
15. THE OWNER WILL NOT BE HELD LIABLE FROM FIELD CHANGES THAT MAY ARISE FROM -------------------------------------------
CONTRACTOR ERROR OR CM1551ON OF MATERIALS OR FROM WORKMANSHIP IN TRADE ' 0'`�i 1/2"CUl I s " VTR MASTER BEDROOM
PERFORMANCE. AA
11 I
� S,� m, E
16. NECESSARY, OBVIOUSLY REQUIRED PLUMBING ITEMS THAT ARE NOT SHOWN ON THESE I , e,, i I ( I 211 5H pq •
DRAWINGS DOES NOT RELIEVE THE PLUMBING CONTRACTOR FROM THEIR RESPONSIBILITY ; ' I 14 311 ,91/811 3" 1/8" 20 FU I FU 'W/C
OF INSTALLING A COMPLETELY OPERATING AND SAFE PLUMBING SYSTEM APPLICABLE w/ SLFFE••osa3 SL
_ ; i , o z
WW O ALL CODES AS PREVIOUSLY DESCRIBED IN NOTE 1 ABOVE. VTR Q ti Fl
I�l 1
11. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL INSPECTIONS
AND CERTIFICATIONS THAT MAY BE REQUIRED DURING AND UPON COMPLETION OF THEIR i 1_1/2"'LAV 2" SN GATE I/2"
WORK ------------------------------------------- C===3 -- -----� I I ( 3"W/C VALVE I HB `o
- -- --- o III TH I m o0
IS. ALL SANITARY PIPING SHALL BE POLY VINYL CHLORIDE ( PVC ), SCHEDULE 40 UNLESS I c`
OTHERWISE NOTED.
f5 M
19. ALL WATER SUPPLY PIPING SHALL BE COPPER, TYPE 'M' ABOVE GROUND, TYPE 'L' BELOW
GROUND, WITH WROUGHT COPPER SOLDERED JOINT FITTINGS WHERE NECESSARY. THERE -
O ..�
SHALL BE NO JOINTS UNDER SLABS ON WATER SUPPLY LINES. NOTE: WHERE PERMITTED BY 1" WATER oo ,
CODE, SCH, 40, C.P.V.C. TUBING MAY BE SUBSTITUTED FOR COPPER TUBING. U- I SUPPLY 'S M
� nl
20. PROVIDE BRASS FITTINGS WHERE NECESSARY OR WHERE GOOD PRACTICE DICTATES.
DINING R®® H N
FOYER
21. PRESSURE AND TEMPERATURE RELIEF LINE SHALL 3/4" O.D. COPPER OR C.P.V.C., (SCHED. CM
- 0 40) AND SHALL DISCHARGE OUTSIDE, 6" ABOVE FIN15H GRADE.
CD
- o SUB-NOTE A). t0 PLUMBING CONTRACTOR: B ®ROOM 2 BEDROOM 3 con
UNLESS OTHERWISE NOTED ON PLAN, ALL SANITARY LINES CAN BE INSTALLED WITH A SLOPE Q�
m' OF 1/4" PER FOOT. HOWEVER, IT IS THE SOLE RESPONSIBILITY OF THE PLUMBING ►-7 w
-' CONTRACTOR TO FIELD VERIFY THE INVERT ELEVATIONS OF THE EXISTING SANITARY LINES, 3t M
IT=-CD PRIOR TO ROUGH-IN, TO INSURE THAT THESE PLANS WILL NOT BE IN CONFLICT WITH THE
-N EXISTING SITE CONDITIONS. IF 50, THE PLUMBING CONTRACTOR SHALL REFER t0 NOTE "6 ����� ® a C�
LL cli HEREIN 4 NOTIFY THE ARCHITECT IMMEDIATELY BEFORE BEGINNING ANY WORK O !.
SUB-NOTE B). t0 BUILDING OFFICIAL: N
3_ THE PURPOSE OF THIS NOTE 15 NOT TO GIVE THE CONTRACTOR AN EITHER / OR OPTION AT d 411 to
a WHICH TO INSTALL HIS BUILDING DRAINAGE PIPING, BUT TO MAINTAIN CONSTANT UNIFORM
J SLOPES OF THAT PIPING. HOWEVER, IN SOME CASES, THE EXISTING SITE CONDITIONS MAY Q cV M
U-' m NOT ALLOW FOR ALL U.G. PIPING t0 BE At 1/4" PER FOOT. IN THOSE CASES, THE PLUMBING
CD
m: 11q CONTRACTOR WILL BE FORCED TO USE THE MINIMUM CODE REQUIREMENTS FOR BUILDING TO a
CD o DRAINAGE PIPING, IN WHICH CASE, ONLY PIPING ON EACH FIXTURE BRANCH SHALL HAVE SEPTIC .
a UNIFORM SLOPES. STEM MEW
cri
o 000000aoa 4
L
F3
Lu =
J .Y
U
M, o
tZ 0-
W t..
J a-..
J 4_1
ri m
P_
/ 3
H 2
U v�
Q � o
CD (-.3
Ln
CD Ln of
00
LU 4-J
, -D
N C
I � i
lD CU
[n O
W
/ C1
/ S
I
i
I