Loading...
00-0046-012 ISSUANCE FOR 0 E3 BIDDING SET ONLY l E3CONSTRUC11IN SET ONLY ❑BUILDING PERMIT SET ONLY REVS .9-8-00 M�' REV2� a' *4 , REV3 LAUND �. i 0x6 � 50 c 100 CFM ELECT. CLOSET I w 1 6"� FLEX 10x6 a AITI(,SEAL HERE METER 100 CFM sc. MAIN PROVIDE EXH. 111 110 ilp `C7 FAN QT-80 DISC. EP 4" VENT. 0x6 I x.100 CFM FA ILY ROOM CFM C 10x6 100 CFM 10x6 i i uo W.I.C. X®OK --- 100 CFM 6 FLEX 6 FLEX ROOD 10x6 10x6 Q ' 44 FLEX 100 CFM 6m FLEX M�n v C� W l 100 CFm , �--�- 6"� FLEX F g ti-I fox(o �� 100 cFM MASTER W ® �+ 10x10 DUCT 12x10 DUCT 12x12 U T / / 10x6 �- F•� 10x10 cFm / / II l 250 CFM i i ° °° �\� / I I 010x6 BATH FM II FLEX i �� O � O � � 10x6 R OM i ,-� U KITCHEN 1 a W Wi !'/z" DRYWALL ' i i 100 CFM ' 10x(O O WD. STUDS I&,, BEDROOM 4, ' 12°m FLEX g O r • o.c_ 6"m FLEX i 12"m FLEX LIVING ROO . . L70) 0 . . W • ' 100 CFM --- 10x6 - -- --- -o ------ x6 UNDER GROUND P STUCCO FINISH OVER 15 CFM �� ATH REFRIG. LINES & 2" � PAPER BACKED METAL I I 4 FLEX _ CONDENSATE LINES IN 10x6 • LATH ON L5 PLYWOOD I � FLEX 0 — 4" P.V.C. PIPE. � N W/ Sd NAILS � 6" O.C. — —— � 125 CFM • 10x6 14"� FLEX nJ4.u. ` ROVIDE EXH. b�l ------- 1 _QT-B4 REF. LINES -- __F_AN_ � � A 3/84 SUCTION 4" VENT. 6"m FLEX l _ rr11 11 F-� 100 CFM V DINING ROOM 06x6 IOx6 = �l FOYER i 6"m FILEx II o • 91 PYC 3/¢,� 100 CFM 10x6 N BEDROOM 2 BEDROOM 3 d ►-a A vs A l� MECHANICAL PLAN i ENTRY � - - - - - - ILO _j C00 U LL ° c.q_� *�+ M o M CD H.V.A.C. ROTES N HVAC DESIGN REQUIRES.. YES NO CD '—' d ALL WORK SHALL CONFORM WITH THE STANDARD BUILDING CODE AND ALL OTHER APPLICABLE STATE AND LOCAL DUCT SMOKE DETECTOR p v--4 cxj FIRE DAMPERS) - oo CONTRACTOR SHALL WARRANT ALL WORK TO BE FREE OF DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD � M SMOKE DAMPER(S) -oc BALANCE ALL SYSTEMS TO PROVIDE AIR QUANTITIES AND CAPACITIES AS INDICATED OR AS REQUIRED BY CODE FETE RATED ENCLOSURE C-) ALL WORK SHALL BE FIELD CHECKED BEFORE INSTALLATION AND COORDINATED WUTH ALL TRADES. FIRE RATED ROOF C®LING ASSEMBLY xA STOPPING FIBROUS DUCT WITH S.M.A.C.N.A. DUCTWORK SHALL BE CLASS 1 GLASS FIBER DUCTBOARD IN ACCORDANCE W ' FIRE � SMOKE CONTROL .,p m PROVIDE VOLUME DAMPERS TURNING VANES, ETC., IN DUCTWORK FOR PROPER AIR FLOW AND BALANCE. PROVIDE �p M a MULTIPLE VANE EXTRACTORS WITH CONTROL RODS AT ALL OUTLETS CONNECTED CLOSER THAN TWO DUCT DIAMETERS O �� o, Con 3 FLEXIBLE DUCTS IF USED SHALL BE THE INSULATED TYPE(MIN. R-6) SUPPORTED AND INSTALLED TO AVOID SAGS AND o i� N w i n, KINKS. ALL FLEXIBLE DUCTS SHALL BE SIMILAR IN LENGTH TO AVOID DISSIMILAR PRESSURE DROPS AND THE LONGEST SPLI`�' SYSTEM Q Z) o°,2: a o°, SCHEDULE REFRIGERANT PIPING SHALL BE SEEMLESS COPPER TYPE "L" HARD OR SOFT DRAWN OR ACR COPPER TUBING WITH F a WROUGHT COPPER SOLDER JOINT FITTINGS. SOLDER SHALL BE 95/5 APPLIED WITH SUITABLE FLUX z3 ,J i �,.;. r-. INSULATE REFRIGERANT SUCTION PIPING WITH 3/4" ARMAFLEX PREMOLDED PIPE INSULATION MANUFACTURER - ,,,;;��' ® � M z INTERCOOL -„',' �o � PROVIDE A/C UNITS WITH MATCHING HEAT — COOL THERMOSTATS WITH ON — OFF AUTO SUB — BASE SWITCH, ` ` u > In �,, PROVIDE ALL NECESSARY INSTRUCTIONS TO THE OWNER FOR OPERATION OF THE SYSTEM INCLUDING OPERATING CONDENSINCx UNIT MO o DEL RAKA-060/DA CONDENSING N D PROVIDE ALL NECESSARY SLEEVES BEFORE CONCRETE IS POURED AND COORDINATE PLANS AND LOCATION OF DUCTS UNIT AIR HANDLER UNIT MODEL RCTB-A06m ® � a WITH TRUSS MANU. AND ARCHITECT PRIOR TO COMMENCING WITH THE WORK. IF CONFLICT ARISES AND NOTIFICATION zn j U3 WAS NOT DONE IT SHALL BE THE RESPONSIBILITY OF THE A/C CONTRACTOR TO FIND A SOLUTION POWER & CONTROL Q N 0 cu VOLTAGE W M 1-60-208/230 CFr1 HIGH ENERGY ROTES CONNECTIONS �_.. 1,600 - sEE.R. o �0�00000� - THE HOUSE MUST COMPLY WITH ALL PRESCRIPTIVE REQUIREMENTS FOR WINDOW, DOOR AND DUCTWORK INFILTRATION i4 ' / i CD AND INCLUDE THE FOLLOWING REQUIREMENTS: TOTAL B.T.U.'S (( a 46,000 9� m HEIM WINDOWS SHALL HAVE A MAXIMUM OF 0.5 CFM PER LINEAR FOOT OF OPERABLE SASH CRACK SENSIBLE B.7,U.'S ;, • 33,920 � •.::.,:. � LATENT B.T.U.'S LIQUID LINE W/0 0 D D D q DOORS INCLUDING SLGL.DRS. SHALL HAVE A MAX. OF 0.5 CFM PER SQ. FT. OF DOOR AREA 13,000 `'�,:,.., CONCRETE BASE 1 /—INSULATION n ' a EXTERIOR JOINTS OR OPENINGS IN THE BUILDING ENVELOPE SHALL BE CAULKED GASKETED WEATHERSTRIPPED MAXIMUM K UJ. HEAT a 13.50KUJ W/6x6-10/10 W WF •a ::':' 11 +, OR OTHERWISE SEALED IN AN APPROVED MANNER 4” 0 SCH 40 rr P.V.C. PIPE 3 H.V.A.C. DUCTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH INDUSTRY STANDARDS AND THE LOCAL MECHANICAL EXT. STATIC PRESSURE 03 COND. UNIT TO BE ALL JOINTS IN DUCTWORK IN UNCONDITIONED SPACES SHALL BE SEALED THERMOSTAT MODEL SECURED TO CONC. SLAB CD T-8340 W/(6) 1-1/2 REMINGTON o� ALL EXHAUST FANS VENTED TO EXTERIOR OR UNCONDITIONED SPACE SHALL HAVE DAMPERS LIQUID/SUCTION SIZE-IN POWER FASTENERS ° � ALL PENETRATIONS, JOINTS AND CRACKS IN INTERIOR SURFACES OF CEILINGS AND EXTERIOR WALLS SHALL BE FAN MOTOR FLQ TO WITHSTAND 110 M.P.H. WINDS INCLUDING THE FOLLOWING COMPONENTS: WINDOW AND DOOR FRAMES, ELECTRICAL OUTLETS, BASEBOARDS, 2.0 ATTIC ACCESSES, AND RECESSED LIGHTING CANS SUCTION LINES FUSE (MIN.) 50/50 -°' THESE PLANS WERE PREPARED TO COMPLY WITH THE BUILDING ENVELOPE ENERGY REQUIREMENTS OF THE FLORIDA o MODEL ENERGY CODE PRESCRIPTIVE #2. INSULATION VALUES ARE AS NOTED ON PLANS. MIN. CIRCUIT AMPAC171' AMPS. 40/40 CONDENSING UNIT MOUNTING DETAIL. of 1 I