Loading...
00-0046-010 j 0 ----- - ----- - ------ ISSUANCE F01 0 ❑BIDDING SET ONLY ❑CONSTRUCTION SET ONLY N ❑BUILDING PERMIT,SET ONLY REA 9--.,8-` Q, MB t ? } J ; REV2 10-.,12-Q01 VB' ;• .f l REVS .J t z Z r _ I I o ^ •�wiY #x _ o LAUNDRY D I I -. 100 CFM ' VA 0x6 ,'.: , 50 C I 10x6 AFFIX`��AC;,F1 k",; l CLOSET I � 0110 FLEX ELECT. \ / METER • esc. PROVIDE EXH. D MAIN. FAN QT-80 I 1 100 CFM FAMILY ROOM E P 0x6 4 VENT. C o E 10x6 100 CFM • • • • • • • • 10x6 NOOK .LC. x fn 6110 FLEX 100 CFM i a iI FLEX 10x6 V m PLAY ROOM 0 g 14 m 4110 FLEX - - - 6ufF W ►� O 100 CFM 6 m FLEx MASTER g I I \�� /, I 10x6 I 50 CFM �A'rH ~ �- A W 10x10 i o `��� /j/ I I 10x6 X50 CFM O 6 250 CFM i i 100 0 �� 10x6 F= vi 8"0 FLEX 100 CFM u i 10x ASTER—BEDROOM i i W ICI 10x6 j 6 FLEX i i <, ' i W KITCHEN „ Q.I.C. � 64 I I FLE 100 CFM qj r�W J h O 1/2 DRYWALL FFE= 10x6 L--- V 12 4 FLEX 2"X6" 5YP No. 2 WD. 5TUD5 a 16" BEDROOM 4 64 FLEX 124 FLEX LIMING RO 0) F�1 . . W z z >-+ U O.G. 100 CFM O 5 c � H • ' F � 6 UNDER GROUND � ~ ------------------------------------------- ----_� 10x6 I II REFRIG. LINES & 2" o �/2" STUCCO FINISH OVER O III 15 CFM 4°4 FLEX ATH CONDENSATE LINES IN ' ' •l• 10x6 4" P.V.C. PIPE. M� PAPER 5AG<ED METAL I I FLEX — LATH ON 5/a" PLYW001) ff W/ 8d NAILS 6" O.G. 125 CFM AFW. PROVIDE EXH. REF. LINES (.L� • 10x6 14"m FLEX' - - -- ---------EW_Q L8Q__ a i—� ------- '" = 3/8 4 SUCTION l ® O _ — — 4" VENT. 3/4"� VAPOR C3 I--1 64 FLEX_­, — — 100 CFM c CFM DINING ROOM 5066 x 10x6 N �l FOYER 6°I FLEx . . • •� PVC 3/4" —*- 100 CFM 10x6 BEDROOM 2 BEDROOM 3 pa . • U � z � w � C—I O i L4 0 � MECHANICAL LA I TRY .L__ . . CD coo - - - - - - O O O cU DR �, •-1 M LID v A,/ cu H. .A.C. NOTES HVAC DESIGN REQUIRES: YES NO O .--{ o ALL WORK SHALL CONFORM WITH THE STANDARD BUILDING CODE AND ALL O1HER APPLICABLE STATE AND LOCAL DUCT SMOKE DETECTOR �1 -60 FIRE DAMPER(S) Li CONTRACTOR SHALL WARRANT ALL WORK TO BE FREE OF DEFECTS IN WORKNANSHIP AND MATERIALS FOR A PERIOD SMOKE DAMPERS) t i= cn BALANCE ALL SYSTEMS TO PROVIDE AIR QUANTITIES AND CAPACITIES AS INDICATED OR AS REQUIRED BY CODE F6RE RATED ENCLOSURE ALL WORK SHALL BE FIELD CHECKED BEFORE INSTALLATION AND COORDINATED WUTH ALL TRADES. FIRE RATED ROOF CEILING ASSEMBLY n cn FIRE DUCTWORK SHALL BE CLASS 1 GLASS FIBER DUCTBOARD IN ACCORDANCE WITH S.M.A.C.N. .'S FIBROUS DUCT STOPPING w SMOKE CONTROL �� U o CD PROVIDE VOLUME DAMPERS TURNING VANES, ETC., IN DUCTWORK FOR PROPER AIR FLOW AND BALANCE. PROVIDE z-=� MULTIPLE VANE EXTRACTORS WITH CONTROL RODS AT ALL OUTLETS CONNECTED CLOSER THAN TWO DUCT DIAMETERS Q J aFLEXIBLE DUCTS IF USED SHALL BE THE INSULATED TYPE(MIN. R-6) SUPPORTED AND INSTALLED TO AVOID SAGS AND ����� SYSTEM z KINKS. ALL FLEXIBLE DUCTS SHALL BE SIMILAR IN LENGTH TO AVOID DISSIMILAR PRESSURE DROPS AND THE LONGEST M Lu REFRIGERANT PIPING SHALL BE SEEMLESS COPPER TYPE "L" HARD OR SOFT DRAWN OR ACR COPPER TUBING WITH WROUGHT COPPER SOLDER JOINT FITTINGS. SOLDER SHALL BE 95/5 APPLIED WITH SUITABLE FLUX. ��;r con pp INSULATE REFRIGERANT SUCTION PIPING WITH 3/4" ARMAFLEX PREMOLDED PIPE INSULATION MANUFACTURER INTERCOOL ` v� M p PROVIDE A/C UNITS WITH MATCHING HEAT - COOL THERMOSTATS WITH ON - OFF AUTO SUB - BASE SWITCH, N ui PROVIDE ALL NECESSARY INSTRUCTIONS TO THE OWNER FOR OPERATION OF THE SYSTEM INCLUDING OPERATING CONDENSING UNIT MODEL RAKA-060/DA CONDENSING CD UNIT PROVIDE ALL NECESSARY SLEEVES BEFORE CONCRETE IS POURED AND COORDINATE PLANS AND LOCATION OF DUCTS AIR HANDLER UNIT MODEL RCT5-AID6ID POWER & CONTROL CD WITH TRUSS MANU. AND ARCHITECT PRIOR TO COMMENCING WITH THE WORK. IF CONFLICT ARISES AND NOTIFICATION yOLTAGE 1-6ID-20$/23ID CONNECTIONS WAS NOT DONE IT SHALL BE THE RESPONSIBILITY OF THE A/C CONTRACTOR TO FIND A SOLUTION '-' ERG C.F111. HIGH 1,600 HUM W Y NOTES -, a S.E.E.R. 11.60 ez THE HOUSE MUST COMPLY WITH ALL PRESCRIPTIVE REQUIREMENTS FOR WINDOW, DOOR AND DUCTWORK INFILTRATION CD AND INCLUDE THE FOLLOWING REQUIREMENTS: TOTAL B.T.U.S 46,000 o SENSIBLE 5.T.U.'S 33,920 = WINDOWS SHALL HAVE A MAXIMUM OF 0.5 CFM PER LINEAR FOOT OF OPERABLE SASH CRACK \ INSULATION LIQUID LINE W/O L di ATENT B.T.U.S 13,000 CONCRETE BASE ., , ; �:° DOORS INCLUDING SL.GL.DRS. SHALL HAVE A MAX. OF 0.5 CFM PER SQ. FT. OF DOOR AREA W/6x6-10/10 W WF CD >. ,. �` 4" 0 SCH 40 ° EXTERIOR JOINTS OR OPENINGS IN THE BUILDING ENVELOPE SHALL BE CAULKED GASKETED WEATHERSTRIPPED MAXIMUM I<M. HEAT 13.50KUJ P.V.C. PIPE wT3� OR OTHERWISE SEALED IN AN APPROVED MANNER EXT. STATIC PRESSURE 03 COND. UNIT TO BE H.V.A.C. DUCTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH INDUSTRY STANDARDS AND THE LOCAL MECHANICAL SECURED TO CONC. SLAB /000 "' THERMOSTAT MODEL T-$34C W/(6) 1-1/2" REMINGTON H ALL JOINTS IN DUCTWORK IN UNCONDITIONED SPACES SHALL BE SEALED POWER FASTENERS w� M- ALL EXHAUST FANS VENTED TO EXTERIOR OR UNCONDITIONED SPACE SHALL HAVE DAMPERS LIQUID/SUCTION SIZE-IN 3/$° - /$° TO WITHSTAND 110 M.P.H. WINDS CD ALL PENETRATIONS, JOINTS AND CRACKS IN INTERIOR SURFACES OF CEILINGS AND EXTERIOR WALLS SHALL BE FAN MOTOR FLA 2.0 SUCTION LINES INCLUDING THE FOLLOWING COMPONENTS: WINDOW AND DOOR FRAMES, ELECTRICAL OUTLETS, BASEBOARDS, ATTIC ACCESSES, AND RECESSED LIGHTING CANS FUSE (MIN.) 50/50 CONDENSING a®e ®� ®� y. o 1 C3 THESE PLANS WERE PREPARED TO COMPLY WITH THE BUILDING ENVELOPE ENERGY REQUIREMENTS OF THE FLORIDA CONDENSING UNIT MOUNTING DETAIL AI` Ol 1 MODEL ENERGY CODE PRESCRIPTIVE #2. INSULATION VALUES ARE AS NOTED ON PLANS. MIN. CIRCUIT AMPACITY AMPS. 40/40 a cn w i i