00-0045-013 a H . V. A. C. NOTES HVAC DESIGN REQUIRES: YES NO ISSUANCE FOR ALL WORK SHALL CONFORM WITH THE STANDARD BUILDING CODE AND ALL OTHER APPLICABLE STATE AND LOCAL DUCT SMOKE DETECTOR X z J FIRE DAMP X ❑BIDDING SET ONLY ERS CONTRACTOR SHALL WARRANT ALL WORK TO BE FREE OF DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD SMOKE DAMPERS o ❑CONSTRUC110N SET ONLY X � � BALANCE ALL SYSTEMS TO PROVIDE AIR QUANTITIES AND CAPACITIES AS INDICATED OR AS REQUIRED BY CODE FIRE RATED ENCLOSURE X o ❑BUILDING 0114Y._ll ALL WORK SHALL BE FIELD CHECKED BEFORE INSTALLATION AND COORDINATED WUTH ALL TRADES. FIRE RATED ROOF CEILING ASSEMBLY X r= REVt yw , DUCTWORK SHALL BE CLASS 1 GLASS FIBER DUCTBOARD IN ACCORDANCE WITH S.M.A.C.N.A.'S FIBROUS DUCT FIRE STOPPING X z REV2 _ ; .,, SMOKE CONTROL X REVS ; PROVIDE VOLUME DAMPERS TURNING VANES, ETC., IN DUCTWORK FOR PROPER AIR FLOW AND BALANCE. PROVIDE ° b 4 ; MULTIPLE VANE EXTRACTORS WITH CONTROL RODS AT ALL OUTLETS CONNECTED CLOSER THAN TWO DUCT DIAMETERS C.0 5 TONS. j FLEXIBLE DUCTS IF USED SHALL BE THE INSULATED TYPE(MIN. R-6) SUPPORTED AND INSTALLED TO AVOID SAGS AND 230/30 , C3 �� ,; ►,,,,�� �;- ALL FLEXIBLE DUCTS SHALL BE SIMILAR IN LENGTH TO AVOID DISSIMILAR N3R-240V. PRESSURE DROPS AND THE LONGEST O REFRIGERANT PIPING SHALL BE SEEMLESS COPPER TYPE "L" HARD OR SOFT DRAWN OR ACR COPPER TUBING WITH p q � WROUGHT COPPER SOLDER JOINT FITTINGS. SOLDER SHALL BE 95/5 APPLIED WITH SUITABLE FLUX. I� a HB INSULATE REFRIGERANT SUCTION PIPING WITH 3/4" ARMAFLEX PREMOLDED PIPE INSULATION DRYWELL AFFIX SEAL HERE o N B PROVIDE A/C UNITS WITH MATCHING HEAT - COOL THERMOSTATS WITH ON - OFF AUTO SUB - BASE SWITCH, } (cb.1scl 1 CD 00 CFM d PROVIDE ALL NECESSARY INSTRUCTIONS TO THE OWNER FOR OPERATION OF THE SYSTEM INCLUDING OPERATING 10X6 w \ / 11 / " o \ ROVIDE Ex 50 CFM 6"- FLEX / PROVIDE ALL NECESSARY SLEEVES BEFORE CONCRETE IS POURED AND COORDINATE PLANS AND LOCATION OF DUCTS FAN QT-80 8 » NOOK \ / ��\ I ! REFRIG. LINES & 2" / / vs WITH TRUSS MANU. AND ARCHITECT PRIOR TO COMMENCING WITH THE WORK. IF CONFLICT ARISES AND NOTIFICATION 4" VENT. \/ I I CONDENSATE LINES IN / WAS NOT DONE IT SHALL BE THE RESPONSIBILITY OF THE A/C CONTRACTOR TO FIND A SOLUTION I I UNDER GROUND / \\ M 4 P.V.C. PIPE_--- T ROVIDE EX O ENERGY NOTES 6"N FLEX / \ 6"N FLEX PROVI EXq- 1 / / O QT-8 _ 125 CFM FAN -80 I I -----, i/-�--�,` f; 4' V m THE HOUSE MUST COMPLY WITH ALL PRESCRIPTIVE REQUIREMENTS FOR WINDOW, DOOR AND DUCTWORK INFILTRATION 10x6 .._. // 100 CFM 1 4 VE I 1 B E D R 0 BEDROOM #2 M k SS__ R € D 0 0 M M A S —R W AND INCLUDE THE FOLLOWING REQUIREMENTS: Z F A M I L Y R O // I- 10x6 I A TH I I ---- --- __ r WINDOWS SHALL HAVE A MAXIMUM OF 0.5 CFM PER LINEAR FOOT OF OPERABLE SASH CRACK / 1 '°- I I I I - I/ I I 50,CFM / / LIVING ROOM o0 50 CFM- EX � X ll // ° 6»N FLEX O 10x8 } ( 1 1f1x6+---1_�/L----- / „N 75 CFM DOORS INCLUDING SL.GL.DRS. SHALL HAVE A MAX. OF 0.5 CFM PER SQ. FT. OF DOOR AREA ° I I I , r FLEX 10 6 ,, FLEX t , EXTERIOR JOINTS OR OPENINGS IN THE BUILDING ENVELOPE SHALL BE CAULKED GASKETED WEATHERSTRIPPED I TCH EN I F.F.E. 0.00 1 6"N FLEX I / / I I }- OR -------� H OTHERWISE SEALED IN AN APPROVED MANNER I I } ; L---�-�� �--,- J ,,`�---------- H.V.A.C. DUCTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH INDUSTRY STANDARDS AND THE LOCAL MECHANICAL I I I � r �% I s ALL JOINTS IN DUCTWORK IN UNCONDITIONED SPACES SHALL BE SEALED // 200OX8 125 CF 8 N FLEA(----� 1 / f x,, ; � �+ U O y WW ° I 10x8 ALL EXHAUST FANS VENTED TO EXTERIOR OR UNCONDITIONED SPACE SHALL HAVE DAMPERS /� } I I ` �� �-�-- � ---� ' § W �I ALL PENETRATIONS, JOINTS AND CRACKS IN INTERIOR SURFACES OF CEILINGS AND EXTERIOR WALLS SHALL BE FLEX [', INCLUDING THE FOLLOWING COMPONENTS: WINDOW AND DOOR FRAMES, ELECTRICAL OUTLETS, BASEBOARDS, 125 CFM -- - - - - - - / O ATTIC ACCESSES, AND RECESSED LIGHTING CANS 10X8 6$),,, FLEX / F�-I / / a W o U THESE PLANS WERE PREPARED TO COMPLY WITH THE BUILDING ENVELOPE ENERGY REQUIREMENTS OF THE FLORIDA 1 p MODEL ENERGY CODE PRESCRIPTIVE #2. INSULATION VALUES ARE AS NOTED ON PLANS. 8_ SPLIT 8"N FLEX 14"N FLEX O 5 / O • • SYSTEM SCHEDULE 6"N FLEX A1Tal1P, N LE — _ //7 -- - — T - -F-A DE E ® 10"N FLEX / F� . . }-- - - -- - -�" / 50 CFM I o c MANUFACTURER RHEEM ELECT. I I 6"N FLEX 1� / 10x6 • • • • METER A I I 1 i 6 N FLEX 1 1 100 CFM CONDENSING UNIT MODEL RAMA-060JAZ/JBZ MAIN E.P. I I + 150 CFM 1 -.. 100 CFM 10x6 "� W. 1 . C. AIR HANDLER UNIT MODEL RCQB-0060 DISC. I I 10x6 I 10x6 W H » AJC � 6 N FLEX F.F.E. -0.583 I !DINING R 0 0 I Z H Q VOLTAGE 1-60-208/230 Hg I I FOYER 1,900 1 1 1 g C.F.M. HIGH s.E.E.R. 6' FLEX 150 CFM ei 12 GARAGE 1 1 1 i + 10x6 g 1 TOTAL B.T.U.'S 57,500 I I _n SENSIBLE B.T.U.'S 40,987 �� - - - - /y 150 CFM LATENT B.T.U.'S 16,513 \L -- -- --v 10x6 9' BEDROOM #3 BEDROOM 4 MAXIMUM K.W. HEAT 1OKW I ; ENTRY - p �j •• [--1 O EXT. STATIC PRESSURE O 0.3 i AQ THERMOSTAT MODEL T-834C Z LIQUID/SUCTION SIZE-IN 3/8" - 1 1/8" I i � i FAN MOTOR FLA 2.0 i FTT I I I I 1 00 Y FUSE (MIN.) 50/50 I HB M cM MIN. CIRCUIT AMPACITY AMPS. 39/39 z 00 ^� J d U 1 izpD cln CD '$ Rn 0 E-� N Q CD MECHANICAL PLAN U CD SCALE: 1 /4" =1 '-0" a C T W a CD Cf] cu CD F5 CD I S 00 COO of o � e � � o o m CONDENSING S t tA • CD "T UNIT N POWER & CONTROL 0 zr � Q NO CONNECTIONS ui CD S U U .,y W > O a N m �Oi4 N •i.. A HOME .• LLI M CD O I \ \ a d LU 000000aoo .� . LIQUID LINE W/O CD M • CONCRETE BASE INSULAl10N M: a W/6x6 -10/10 W WF » N 11 4 0 SCH 40 rr � a P.V.C. PIPE Lu CD COND. UNIT TO BE H SECURED TO CONC. SLAB \\�� / W/(6) 1-1/2° REMINGTON \� POWER FASTENERS a TO WITHSTAND 110 M.P.H. WINDS CD CC a SUCTION LINES I? LCI U - - r CD W N C CONDENSING UNIT MOUNTING DETAIL j I cn cn o of 1 Di / 0-