00-0646-022 REVISION BY
PERMIT EB
8/18/00
•
_..................................................................................... 20 AS-BUILT MM
25
0
.... .... .........:::::
..... 2
......:.....................
:..................:. 12
x12 Cp
35®
2
RTU-2
€:<€
SUPPORT FROM ROOF -
1�'4 ,
STRUCTURE AS REQUERED ..................
GALVANIZED STEEL :::::: 1
O O
STRUCTURALFRAME ........................ ..........:............... ............. ...............i
.................5.....MIN. 4x4 WF —
-- -
; .;<s I
;.. ?
d� 350*CFM O O CC2
v ea O
: ... ...........
DUCT
M--1
18x14 RETUt�I � .�—•1 d� d�
/1\ 24' HEIGHT - - Imx18 SUPPLY O ,mod,
1x8 _
10 4, ' 1 1/2 0 ``i DUCT O ep
f
d. ...... _ 6FI!°ERE
16x1
^ p U
.....
I U � 0 0
/f\ Q; c+� m
:.....,. I
:,.....,
PIPE COLUMN-----' 1 xl4 4-)
MIN_3'0 a. O °,:s �i 44
O
/1\
... ......... °..... a
:.....::
;.....;: : \—NEU) RTU- _
a� �a 12x12
1
............
;.....is ...........<..................i..................i.............. :
......................•.................i.................,' -
..............f.............. •� cd
o .
to
,t ltt:::�,ttttt fist,tt
�tl,tttt, ,tttttt
L) Q)
�-1
NOTES- ;..... , i i,t,titt W C'7
O
:.....,:
3
• w
xl2 CD
50 t:Fi"I
1- PERMANENTLY MOUNTED ROOFTOP EGlUIPMENt SHALL BE INSTALLED •��••••�•••••••••;••••••••..........;. -
W/ CLEARANCES EQUAL TO ONE-HALF THE DIMENSION OF THE :.....; N
SHORTEST SIDE (WIDTH) OF THE ROOFTOP UNIT W/ A MAX D d
REQUIRED HEIGHT OF FORTY C409 INCHES t A MIN. CLEARANCE '
BETWEEN THE ROOF SURFACE AND THE SUPPORT FRAME OF EIGHTEEN
O 'ti
C189 INCHES. = '
`I- 12xlfd
2- SITE STRUCTURAL FRAME SUCH THAT FLANGE PENETRATIONS FAVOR
:' O € O
LOCATIONS OF SECURING € € ...............................................:....... ........... ........... �+
..... I Cd
RING EQUIPMENT. PROVIDE CROSS MENBERS .....
::::::
�-I
AS REQ'p. ALL JOINTS TO BE COPED AND WELDED. • : � x �
3- HOT DIP GALVANIZED AFTER FABRICATION. 12x12;CD M Lj
i 35m CFM
,�,. ....
MECHANICAL EQUIPMENT
................:...
STAND DETAIL
:,.....,
N.T.S.
............
O O •
i
i!I.J..[.1.1..[.I...(.I.1..1.I..[.(.1..[.I.l..f.I.1..C.I.1..[.I.l..(.I.1..(.I.1..[.I.1 ......::::::: � I.1..(.I.1..f.l.l..(.I..[...1......I.1:.[:I:l::(:I:1::[:I:1::(:1:7::[:l:l::l1
................ ...............................................................................
............................................................................................................................
........................................................................................................................................................................................................................................................................................
0
SECOND FLOOR PLAN
SCALE: 1/4" - V-011
a
0 •
LL! 0
AIR DISTRIBUTION DEVICES:
® Uj L
1- CEILING DIFFUSERS SHALL BE TITUS No. TMs-FR
WITH RADIANT DAMPER OR APPROVED EQUAL.
2- RETURN AIR GRILL SHALL BE TITUS SmFF-FR WITH RADIANT
® ® _
DAMPER AND FILLER OR APPROVED EQUAL-INSTALL As PER UL263
0m CO 3:
E
0 � � 0
DRAIRM
CHECKED
DATE
10 18/9 9
DCALE
1/4"
1
JOB NO.
' � X C. Pugs and Associates, Inc.
a> '} Engineers/Consultants GMET
# ED 0005813
4970 SAT. 72 Avenue, #107
•• C rti l/ 'r, Miami, Florida 33155
\�•"," �,, (305) 661-7700
`CIO of 3 GHEEre