00-0646-017 - - _ r"v' .,I D�f E - 1 - - TIME CLOCKS - -- tjC TjC EXISTING 3-03, THWN CU WIRE IN 15'c EXISTING FROM GUTTER t0 PANEL _ OVERHEAD — -- —-- SERVICE 1400 1.60 FLOOD ' FROM FPL FUrtr' Lra (REC! j ! ! ----- -------------------------------- ------------------------------------- TO RTU-I I ! ! A-23 I ! O A-23 i A-26,28 ! PANEL PANEL ! ! NA1 60 100 A-25 I E METER CAN 200A 2— 2 !r—— —–� 60 2 —3R ! 400A M.G.B. 60 100 t ! it RTU-2 I NP ! MAIN MAIN MAIN IOF3 2OF3 30F3 I it I i CUCNPD LINE GUTTER 8'x8', N3R d A-23 i �Ii� W.PJGr-.I. ! 1 'i5 KVA 1 r , L- - -JL -j ON ROOF i ! 5-10 ' MIN ALL EQUIPMENT AND WIRING SHOWN ON THIS = RISER DIAGRAM ARE EXISTING TO REMAIN A-25 I ! ! ! I i ........ : ... 1 ' GNp RODS o - I ! LCD i .....................................................................................! �-.� I I A-11,19 ELECTRICAL R15E ` D I,4GdRAM TO MAIN «2 OP 3 i � � O � N �2 30 i2'%, 3/4'C) .... ! M O Nt -t 00 NP _ ! .......0 I AHU-I 1 I RTU-1 1 2 NF 3R A-21 l ;....... 1 e� � I '� co � ( .® � �c • LOCATED IN A-25 1St FLOOR 1 1 Ii CEILING AREA ! PANEL A 100.12 KVA)1 TYPE BQD-QO ITE MAINS 200A M.C.B. A-22,24 -- I! ������� ELECTRICAL I�1OT�S ! � � � MNT . SURFACE BUS 200A _ - (EXISTING) 60 � W.PJGF.I. �----- ! � � ( I! LOG ELECTRICAL ROOM VOLTS 120/240, 1PHS, 3W 2 NP 3R �`H'� ON ROOF ? li - ALL ELECTRICAL WORK P WORMED UNDER THIS CONTRACT SHALL ' FEEDER EXISTING 200A 8-10 COMPLY WITH LOCAL CODES AND ORDINANCES AND ALL STANDARDS -- 1 CU-1 1(—LOCATED ON ...... 6 ! OF CONSTRUCTION ESTAB (SHED BY THE LANDLORD. ! Q CKT POLE KVA DESCRIPTION WIRE, G CKT POLE KVA DESCRIPTION WIRE, C -- L —-J ROOF ! ® J A-21 ! - SUBMIT SHOP DRAWINGS R ACCEPTANCE BY THE ARCHITECT ! , (A)- 1 1/20 054 RECEPTACLE EXISTING 2 2/30 45 WATER HEATER EXISTING -(A) --° ! AND/OR ENGINEER BEFO PROCEEDING WITH THE PURCHASE OR ! f! 0 INSTALLATION OF THE EQ IPMENt AND MATERIALS. NO FACSIMILE ! j - (A)- 3 1/20 054 RECEPTACLE EXISTING 4 ! � • = ( OR FACSIMILE COPIES SHALL BE ACCEPTED. (A)- 5 1/20 030 TEL. EXISTING 6 1/20 0.1 CIRC. PUMP EXISTING -(A) � ! - ALL CONDUCTORS SHALL BE THW OR tHWN COPPER ALL EXPOSED ! � � � � (A)- -1 1/20 054 RECEPTACLE EXISTING 8 1/20 036 RECEPTACLE EXISTING -(A) A-21 j E CONDUITS SHALL 5E RUN S NEAT AS POSSIBLE. P.V.C. CONDUIT i I •� 0 (A)- 9 1/20 1.0 LIGHTING EXISTING 10 1/20 028 METER ROOM EXISTING -(A) J ! SHALL ONLY BE USED IN LAB OR UNDERGROUND AT A MINIMUM ! Q N. (A)- 11 1/20 10 LIGHTING EXISTING 12 1/20 1.0 LIGHTING EXISTING -(AJ 1 ' I DEPTH OF 24 INCHES. (A)- 13 1/20 054 RECEPTACLE EXISTING 14 1/20 054 RECEPTACLE EXISTING -(A) I - ! i PLEX15LE CONDUIT SHALL BE USED FOR CONNECTION TO ALL (e)- 15 1/20 135 LIGHTING 2-"12, 1/2 16 1/20 05 HALL LIGHTING EXISTING -(A) I VIBRATING EQUIPMENT SU HAS MOTORS, ETC. (C)- 11 2/30 53 AHU-1 2-010, 3/4 18 1/20 054 RECEPTACLE EXISTING -(A) .� - ALL WIRING DEVICES SHALL BE LEVITON COMMERCIAL GRADE OR ! Is 20 1/20 054 RECEPTACLE EXISTING -(A) '4'21 EQUAL AS APPROVED B ARCHITECT OR ENGINEER ! i (C)- Zl 1/20 054 RECEPTACLE 2-012, I/2 22 2/40 42 CU-1 2-08, 3/4 -(C) p....... j - ALL RECEPTACLES SHAL BE INSTALLED AT 18' AFF. UNLESS i ( C.0 0 (C)- 23 1/20 054 RECEPTACLE 2-012, 1/2 24 ;....... J ' OTHERWISE NOTED. ! � ra j ! (C)- 25 1/20 054 RECEPTACLE 2-012, 1/2 26 2/40 '15'1 RTU-2 2-05, 3/4 -(C) A-2� - /� (� - ELECTRICAL POWER AND CONTROL WIRING FOR H.V.AC. AND MECHANICAL EQUIPMENT HALL BE 1=URNISHED AND INSTALLED BY THE J (C)- 2'1 1/20 0.712 RECEPTACLE 2-�12, 1/2 28 A 21 A-2-1 1 i ELECTRICAL CONTRACTOR. - TOTAL 13.45 KVA TOTAL 20.13 KVA •••--•- ;....--- I� i ! ! - ELECTRICAL CONTRACTOR SHALL VERIFY THE CEILING FINISHES AND ! I ! SUSPENSION SYSTEMS FOR SELECTION OP THE PROPER TRIM AND I ! SUPPORT' ARRANGEMENTS OF THE FIXTURE. ! 3358 KVA - TOTAL CONNECTED LOAD � ! j ! ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH THE 139.91 AMPS 1 ! 3358 KVA / 240 ARCHITECT BEFORE ROUGH INSTALLATION OF LIGHTS, RECEPTACLES, ! SWITCHES AND EQUIPMEN FOR EXACT LOCATION ! ALL ELECTRICAL EQUIPM T MUST BE U.L. APPROVED. i ! ALL BRANCH CIRCUITS S ALL BE SIZED IN ACCORDANCE WITH N.E.C. j i 210-19 REGARDLESS OF SIZES SHOWN ON PLANS OR PANEL SCHEDULES. TYPE ItE ........ 1 PANEL B MAINS : M.L.O. ! !vry MNT FLUSH BUS : 125A .......................:........................................................................................................................................................................................}..... - (EXISTING) I ! � .z.-.... LOC : OFFICE AREA VOLTS 120/240, 1PHS, 3W ! f� FEEDER : EXISTING 3-03, 15'C ! „ ! f ..................................................................................................E ! CKT POLE KVA DESCRIPTION WIRE, C CKT POLE KVA DESCRIPTION WIRE, C ! .............................................................A............-............................................................................................................................................._.....................................................................................................- - (A)- 1 1/20 150 SMALL APPLIANCES EXISTING 2 1/20 12 DISH WASHER EXISTING -lA) (A)- 3 1/20 1.0 LIGHTING EXISTING 4 1/20 1.0 LIGHTING EXISTING -(A) (A)- 5 1/20 054 RECEPTACLE EXISTING 6 2X1/20 2.0 LIGHTING EXISTING -(A) (A)- "i 1/20 0S4 RECEPTACLE EXISTING 8 1/20 1� LIGHTING EXISTING -(A) `� :.... (A)- 9 1/20 054 RECEPTACLE EXISTING 10 1/20 036 RECEPTACLE GFI 2-012, 1/2 -lGJ (A)- Il 1/20 036 GFI CB RECEPTACLE EXISTING 12 SPACE - -, ELECTRICAL POWER PLAN - - (A)- 13 1/20 054 RECEPTACLE EXISTING 14 1/20 054 RECEPTACLE EXISTING -CAJ 15 SPACE 16 1/20 1.0 REFRIGERATOR EXISTING -(A) SCALE: 1 /4" = 1 '-0" TOTAL 5.02 KVA TOTAL "1.10 KVA 12.12 KVA - TOTAL CONNECTED LOAD 12.12 KVA / 240 = 505 AMPS BUILDING MAINS - ELECTRICAL LOAD CALCULATION _ ^^ MAIN ##1 OF 3 = 33.58 kVA EXISTING CKT t0 REMAIN MAIN #2 OF 3 �PANEL)W)RTU-1 = 10.12 kVA MAIN 3 OF 3 PANEL 'B')= 12.12 kVA (B)- EXISTING CKT t BREAKER TO BE RE-USED, Total Demand Load = 55.82 kVA ..j PROVIDE NEW BRANCH CONDUIT E WIRE. , (C)- NEW CIRCUIT FROM EXISTING PANEL PROVIDE NEW BREAKER, CONDUIT AND WIRE. 55,820 VA / 240 = 232.58 Amps SERVICE PROVIDED = 400 AMPS ® 240 VOLT C. c IMM 10 18 car _ - 1/4 = 1 C M.