00-0635-001 not i KUVUL11 AN DADE COUNTY, FLORIDA
M®ADE
0,
v
EMMOMEWAL P43CK IM HAFT
64VIRONMENTAL REVIEW OF DRAINAGE SYSTEM Pt l�
»>KvR tsTaTrim
MLW.'FLOFMAM-ISM
Date �u4L-APT p�a�,is3o
Proje Gm U i w -,16 cT
Location �-►
Section_ L5 Townsship__.i _ Range—IF-L_ Tentative Piat
Location within C.O.I -Trees
Basin
Review for Compliance with Dade County Aquifer Protection Requirements,
Provide Oil and Grease Interceptors at all.Catch Basins preceding French Drains,
as per attached.standard details.
Provide OR and Grease Interceptors at Structure No.:
[� All French Drains to have invert of perforated pipe and miniannm elevation of
Oct.ground water level of— "3 •a NGVD or higher.
Review for compliance with Section 24.12.1 of Metropolitan,Dade County Code.
COMMENTS:
I. French Drains shall be as-per SDIJ - =
2. Catch Basin shall be as per SD2.6 with Oil & Grease interceptors
preceding all French Drains. `
3. Property line must be graded to avoid runoff into adjacent propzrty.�
4. This review is for Stormwater Quality only; Stormwater Quantky`to he
reviewed by Public Works Department.
Outside C.O.I.
I. Design for compliance with D.C.Aquifer Protection R - �
� egoirementc��_� -
2. Commercial/Industrial & Residential with Parking Area,provide Poialon. `
Retardent Structures at all Catch Basins.
Inside C.O.I
Design for compliance with Dade County Code Chapter 24.12
Reviewed by—&L. DC 3 a