00-0630-023 ELECTRICAL NOTES: ELECTRICAL LEGEND: 1. OUTSIDE RECEPTACLES, RECEPTACLES AT BATH, GARAGE AND $ SWITCH TELEVISION ANTENNA ALL KITCHEN RECEPTACLES, SHALL BE G.F.I. $3 THREE-WAY SWITCH TELEPHONE JACK 2. SMOKE DETECTOR HARDWIRED TO KITCHEN OR BATHROOM NON-SWITCHABLE NO GF.I. LIGHTING CIRCUIT INTERCONNECTED DUPLEX RECEPTACLE ® SMOKE DETECTOR W/ SD BATTERY BACKUP AND WITH BATTERY BACK-UP. ® POLED DUPLEX RECEPTACLE 3. ELECTRICAL METER AND PANEL LOCATION MAY VARY AS PER E]J DISCONNECT SWITCH SERVICE ENTRANCE LOCATION SINGLE RECEPTACLE f� ELECTRIC PANEL ® ■ ■ — 4. ELECTRICAL CONTRACTOR TO COORDINATE SERVICE WITH F.P.L. SPECIAL RECEPTACLE F _ ED ELECTRIC METER CEILING MOUNTED FIXTURE 5. ALL V BOXES SHALL COMPLY WITH N.E.C. 310-1-1A. WP WEATHER PROOF WALL MOUNTED FIXTURE 6. MAXIMUM NUMBER OF OUTLETS PER CIRCUIT SHALL COMPLY WITH GU=I GROUND FAULTED SF.B.C. 1994 DADE COUNTY EDITION (TABLE 45-A). ® RECESSED CEILING FIXTURE INTERRUPTER 1. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW EXHAUST FAN HB HOSE 513�! -f— BASE FLOOD ELEVATION SHALL BE INSTALLED AT THE DOORBELL HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED D5 �] DIMMER ON (SEPARATE) INDEPENDENT CIRCUITS FROM TH05E IN THE HABITAL AREAS. PUSH-BUTTON D 1' X 4' FLOURESCENT PB LIGHT 8. NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE (S) DISPOSAL INSTALLED BELOW BASE FLOOD ELEVATION. Jill I S. A/C COMPRESSOR SHALL BE INSTALLED ABOVE BASE 29 290 0 280 \ / 28 FLOOD ELEVATION 10. MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION. \ / 50 C .''+<t� '•, '' �L ;. I1. IT IS SUGGESTED THAT YOU CONFER WITH FLORIDA POWER .t1 is �, , + � -,i 9 •1� L f AND LIGHT TO LOCATE THE ELECTRICAL METER TO COMPLY \ / 26 / 28 28 WITH FEDERAL EMERGENCY MANGEMENT AGENCY REQUIREMENTS \ / i ( •�� 12. ALL ELECTRICAL CONDUCTORS, AND EQUIPMENT TERMINALS, 29 29 SHALL BE RATED FOR 15 C. USE (MIN.) 29 ' �j � Y�•(( Fol / 20 2 8 r, / \ \ 28 20 O 2 _ _ / 25 / 3W -t----- ---- -------- Q 920 - - 24 20 I 20 - --------------------- _ w 2 3m 2 NEMA 1 i 20 �� I II15 � 27 27 <- I _ -----==-- ° 30-32�]_j 29 ------� / i O t �. 27 \ 27 255 i \ / Z V. 24 5 27 0�-02-2(400 -! P• � No. DATE ` \ / REVIS19W 30 O 30 Fi , _5 24-' 27 !JR INFORMATION ONLY �I NOT FOR CONSTRUCTION ❑ NOT FOR PERMIT ❑ FOR PERMIT ❑ DRB ® ( 1 W � 0 U - - - — z w ., -- - - - - - - - - - _- - w z IL N o � _ cj) 0 1 wN � Q Imo 2 � ZOD w o , !� ZQcr) � ? aN o I wrj) co J ,§^ C3 CC u, m ~ 0 O LO W Lf) I -Jc!) (j) w �to 1 I FLAN DESCRIPTION 5 COI � D ELECTFRICAL F1.._ OOR FL AI �1 � � ELECTRICAL !.� SECOND F.PLAN SCALE 1/4•-1'-0' PROJECT NUMBER 2000-1 DATE SHEET NUMBER E-2