Loading...
00-0630-022 ELECTRICAL NOTES: ELECTRICAL LEGEND: ^ 1. OUTSIDE RECEPTACLES, RECEPTACLES AT BATH, GARAGE AND $ SWITCH TELEV15ION ANTENNA ALL KITCHEN RECEPTACLES, SHALL BE GF.I. 2. SMOKE DETECTOR HARDWIRED TO KITCHEN OR BATHROOM $3 THREE-WAY SWITCH TELEPHONE JACK NON-SWITCPABLE NO GF.I. LIGHTING CIRCUIT INTERCONNECTED D� DIMMER ® SMOKE DETECTOR W/ AND WITH BATTERY BACK-UP. SD BATTERY BACKUP 3. ELECTRICAL METER AND PANEL LOCATION MAY VARY AS PER DUPLEX RECEPTACLE E:].J DISCONNECT SWITCH SERVICE ENTRANCE LOCATION. POLED DUPLEX RECEPTACLE ELECTRIC PANEL 4. ELECTRICAL CONTRACTOR TO COORDINATE SERVICE WITH F.P.L. (P SINGLE RECEPTACLE ED ELECTRIC METER 5. ALL 'J' BOXES SHALL COMPLY WITH N.E.G. 310-11A FR RANGE OUTLET Wp WEATHER PROOF 6. MAXIMUM NUMBER OF OUTLETS PER CIRCUIT SHALL COMPLY WITH SPECIAL RECEPTACLE GROUND FAULTED SFB 199 .G. 4 DADE COUNTY EDITION (TABLE 45-A). GFI INTERRUPTER Q CEILING MOUNTED FIXTURE 1. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW Q WALL MOUNTED FIXTURE -+-He HOSE BIB 21 2 BASE FLOOD ELEVATION SHALL BE INSTALLED AT THE 20 HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED ® RECESSED CEILING FIXTURE Z EXHAUST FAN ON (SEPARATE) INDEPENDENT CIRCUITS FROM THOSE IN THE HABITAL AREAS. POST LIGHT / \ 8. NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE / INSTALLED BELOW BASE FLOOD ELEVATION. O 1' X 4' FLOURESCENT LIGHT 9. A/C COMPRESSOR SHALL BE INSTALLED ABOVE BASE DOORBELL / \ 20 y FLOOD ELEVATION D5 10. MAIN CIRCUIT BREAKER PANELS SHALL AT H- // 120 I 3WI / / \ 21 P L LL BE LOCATED PB PUS BUTTON yyp ABOVE BASE FLOOD ELEVATION. / \ GFI 21 _ 3W 11. IT 15 SUGGESTED THAT YOU CONFER WITH FLORIDA POWER / / 3W I _3 AND LIGHT TO LOCATE THE ELECTRICAL METER TO COMPLY 3W 3W / 2 B I / / WITH FEDERAL EMERGENCY MANGEMENT AGENCY REQUIREMENTS 19 12. ALL ELECTRICAL CONDUCTORS, AND EQUIPMENT TERMINALS, 22 - -- -----�---- 16 I 17 FI 2 3 0 0 0 0 GFI SHALL BE RATED FOR 15 C. USE (MIN.) 22 19 20 1 \ 1GFI ( 22 _ ELECTRICAL CALCULATION TONE 69 NEI I 22 _. / SINGLE FAMILY RESIDENCES OPTIONAL NEC 220-3 SINGLE PHASE 3 WIRE 110/120 V 1 AM • c , 50 P SERVICE I 19 � / I 22 •.(1 �� , f CIRCUIT DESCRIPTION LOAD POLE TRIP WIRE / 3 I REFRIGERATOR 0.80 1 20 2.12 \ 19 22 / I GFI 2 DISHWASHER IZ0 1 20 2.12 20 \ I / /..�22 �Z s G':•• ,; .- 3 DISPOSAL 120 1 20 2'12 4,6 RANGE W/ OVEN 12.00 2 50 3.6 @ / / I ��iFl ' - - �""��! °' •. N V 5,l WATER HEeTE�' 4.50 2 25 2.10 16 t ------ 13 WASHER 1.50 1 20 2012 ------------------- � i / 12,14 DRYER 5.00 2 30 3.10 20 \23 i �22 / 15 GARAGE OPENER 1200 1 15 2.14 0 \ / � / 160 17 16.11,18, APPLIANCES 450 1 20 2.12 8-10 22 / 3W 19-29 5F. a .003 1 15 AMPS 2.14 TH-ROMEX 2-1 30 2 NEMA I 3W / 30 BATHROOM GFI 3.6 1 20 AMPS 2012 o -I 20 ' I 0 34,38 SPARE 5 7 � 22 23 �23 23 / \ i GFI � / / \ ` X22 I SUB-TOTAL 35,5 / 1 5T 10 KW a 10090 10.00 '�------� z \ REMAINDER + o 40% 14.0 / 0 / I � SUB-TOTAL 24.0 `------J 18 0 0'1-02-2000 60 40 31 33 8,10 A.H.U. 01 HEAT 10.0 2 50 AMPS 2% \ No. DATE 9,11 COMP. 01 (3 S TnNS) 4 2 40 2010 � -023 REVISIONS 30-32 A.H.U. 01 HEAT 10.0 2 50 AMPS 2% 40 2 9 1 \ 18 FOR FORMATION ONLY 31-33 COMP. of (3 TepPIS) 4 2 40 2.10 --023 ❑ NOT FOR CONSTRUCTION TOTAL LOAD (KW) GFI ------ 23 r-------- ----------------- � NOT FOR PERMIT 1833 G011 GFI 23 ❑ FOR PERMR KW/240 (= AMPS) I 15 I j ❑ DRB I I I I 3 •2/0 THW CU. I 4/to i I IN 2' C. 22,000 A/G I 200 AMP. ELECT. U PANEL MLO 5N. I Z W ELECTRICAL METE I I W �, Z 200 AMP DISC. � o � Q 22,000 AMP A.I.R. W 2' RGC TO 1 • 4TW GU IN 1 2 W � POWER COMPANY - C TRANSFER PAD COND. TO CWP. Q ' • L HOUSE CONCRETE }� Z /n FOUNDATION 8'-0' DEEP GROUNDING illi - W� ROD - 5/8' DIAMETER - Z T) M 00) • 5 FOUNDATION Q O 2 a (� •4 CONDUCTOR TO 20 FOOT REBAR MIN. 20 FT. W -to, O SECTION OF FOUNDATION STEEL LONG V tl* w � J (9 0 Q- mwuj to O O J 2 0 ELECTRICAL RISER N.T.S. � � m � � JawW � ELECTRICAL F L AN 1 /4 1 1 SHEET DESCRIPTION ELECTRICAL FLOOR FPL MAXIMUM AT METER USE 22,000 A.I.C. MINIMUM PLAN AVAILABLE: AT LOADCENTER = USE 22,000 A.I.C. MINIMUM SCALE 26,194 A.I.C. SEE CALCULATIONS BELOW 1/4'x1'-0' PROJECT NUMBER 2000-1 DATE SHEET NUMBER E-1 -