00-0630-006 FLOOR PLAN LEGEND: REFRIGERATOR SPACE © ELECTRICAL PANEL 7 F.DOOR 3 .DOOR 7 F.DOOR SH 35 ® DOUBLE SINK W/ DISPOSAL ® DRYWALL FINISHED LINEN +43.61-55.3 +47. -49.9 +43.6-46.5 +44.8 47.7 © UNDER THE COUNTER DISHWASHER CLOSET W/ SHELVES ZONE 5 ZONE 4 ZONE 4 ZONE 4 ® DOUBLE OVEN ® DRYWALL FINISH NICHE, 49'--10" WITH SILL AT 36" A.F.F. 0 SURFACE MOUNTED COOKTOP, W/ O WASHER AND DRYER 29'-10" MICROWAVE AND HOOD ABOVE VENT DRYER TO EXTERIOR 20 -0" DRYWALL FINISHED PANTRY �T DRYWALL FINISHED DECORATIVE COLUMNS, 12" DIA. (NON-STRUCTURAL) „ , „ f © 36' HGT. A.F.F. KITCHEN COUNTER -4' 8'-9 -4 91-11, -4 8 -0 9 -10 10'-2" DU DRYWALL FINISHED ARCHED TRANSOM, 42" HGT. A.F.F. KITCHEN COUNTER W/ TOP OF ARCH AT 12'-11" HGT. A.F.F. (�I 22"X 32" ATTIC ACCESS PANEL Q VEGETABLE SINK _...... _.. a....w._._.......................... . ._.................. ,�..... _. JO ELECTRIC WATER HEATER ® BUILT IN LAUNDRY SINK KO AIR HANDLER UNIT #1 0 LINE OF WALL CABINETS ABOVE 0 A/C CONDENSING UNIT #1 � TEMP. GLASS SHOWER ENCLOSURE REFER TO DETAIL ON SHEET D-3 Q DRYWALL FINISHED ARCHED TRANSOM, o i' � z '� FAMILY ROOM WITH TOP OF ARCH AT 8'-0" �. L` z N ( N \ + o ° 4'-0'- 6, 4r, 2'-8" 21-6 6'-3" 6r 4„ _ 18'-0" ;� 00 AREA CALCULATIONS: 00 A/C SPACE (GROUND FLOOR) 1,326 SQUARE FEET o A/C SPACE (SECOND FLOOR) 1,476 SQUARE FEET TOTAL A/C SPACE 2,802 SQUARE FEET GARAGE 482 SQUARE FEET ? iti _ 2'-O" 13'-10" TERRACE 310 SQUARE FEET ENTRY 105 SQUARE FEET 6'-O" 4'-5" 2 -9 8 r 00 TOTAL 3,699 SQUARE FEET _ _ r � WALL LEGEND �� � _ �� N I I 1 I -- N r 1- z 0 INDICATES 8"x8"x16" MASONRY UNITS = INDICATES 2X4 WD. BEARING PARTITION WITH STUDS AT 16" O.C. (TYP.) WITH 1 LAYER `V € ' r, rr r „ , ° OF 5/8" TYPE 'X' DRYWALL FINISH EACH SIDE 12f-0 5p 14'-4" I " ' 4' "'• INDICATES 3-5/8" METAL STUDS PARTITION (FULL HGT. WALL) w N j WITH 1/2" DRYWALL FINISH EACH SIDE. W/ MTL. STUDS @ 24" O.C. (1 HR. FIRE RATED CONSTRUCTION) PROVIDE _ ,-" ! 15'-6" _ r- A MIN. OF (3) 2 X 4'S AT EACH END OF BRNG. �r = PARTITION _I I I Lf) 00 NDICATES 3-5/8' METAL STUDS PARTITION (PARTIAL HGT. WALL) o 3 I w I WITH 1/2" DRYWALL FINISH EACH SIDE. W/ MTL. STUDS ® 24" O.C. BREAKFA I CO d z BED OOM NO. 2 ABANA _ `r O [ ONE LAYER OF 5/8" TYPE X GYPSUM WALLBOARD OR VENEER - - -71' � ; LIVING _ 00 + N $ 10 3 1 3 -o i KITCHEN BASE APPLIED AT RIGHT ANGLES OR PARALLEL TO EACH .(2: j SIDE OF 3-5/8" METAL STUDS 24" O.C. WITH 1" TYPE 'S' -' ° (0 b DRYWALL SCREWS 8" O.C. TO VERTICAL EDGES, TOP, AND T ! ,'; N co ' BOTTOM RUNNERS AND 12" O.C. TO INTERMEDIATE STUDS. _ I 00 STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24" O.C. .-``-" `� I U N I z EACH SIDE. (NLB) & R-11 INSULATION BETWEEN STUDS O i� �,`O cD I y 1 v7 + N ............................ .. O _. __ :�� �ap.:.................... DOOR SCHEDULE o ° I € 0 .. . .._ N ' 5 N N0. DOOR FRAME REMARKS ° _ 00 00 TOP OF CONCRETE SLAB o _ °- ELEV. 0'-O" _I r „ , r f u , " LO W H T MAT. TYPE GLASS MAT. DET. 2 6;> O N 9,_4„ ;..� ,.r� _ 2 -0 5 10 3 -4 4'-0" 1 2-3'- MTL. THRESHOLD, WEATHER STRIP, 6'-8" 1 3/8" H.C. WD. SWING WD. DOOR SCOPE RAISED PANEL` ;.:a = � N * 2 METAL CLAD C' LABEL DOOR, W AUTOMATED ..............................E p.................. - 2'-8" 6'-8" 1 3/4' H.C. WD. SWING WD. SELF CLOSING DEVICE, MTL. THRESHOLD t0 O r " " " " " " " " "_ MARBLE SADDLE AT BATHROOMS `'� O_ I 3 2'-0" 8'-0" 1 3/8" H.C. WD. SWING WD. ONLY, RAISED PANELS '-o" I 3'-11" 2'-$" /� 7' 1" / 9'-2" " > 8,-8" i•� MARBLE SADDLE AT BATHROOMS ° = n N 5 2'-8" 6'-8" 1 3/8" H.C. WD. SWING WD. ONLY, RAISED PANELS f/ I ��. -� = O I W 6 2'-0" 6'-8" 1 1/8" WD. BI-FOLD WD. FULL LOUVERED " M = .n FOYER "� '' 2 MTL. THRESHOLD, WEATHER STRIP. _......... ............................ ..............__.,...........7.... ../ - 1" 5'-4" ;� - 7 2-3'-0' 8'-0" 1 3/4" S.C. WD. SWING 1/4" TEMP. WD. " -�"-E _ _ `::; o o DINING ROOM PROVIDE 120 SQ. INCHES OF * 8 16'-0" 7'-O" MTL. O.H. GARAGE WD. ! € _ Y I O SCREENED VENT PROVID 120 SQ. INCH. OF - VENTILATION 7' FROM F. F. ! 0 € 9 6'-0" 6'-8" 1 1/8" WD. BI-PASS WD MARBLE SADDLE AT BATHROOMS - 1 d- / ONLY, MIRRORED IN MASTER BEDRM. to € € t :€ I':,I � 10 3'-0" 6'-8" 1 1/8" WD. BI-FOLD WD. FULL LOUVERED ; ; �• e w N � Z / `•? -��Ems--ie N + N J .... L8- ALL AHU CLOSET DOORS SHALL BE FULL WOOD LOUVERED DOOR FRAME SHALL BE SOLID 2" X 4" RABBETED WOOD FRAME i " "� 20'-O" _ 8' 6" 6'-6 12'-201-24-01 Lu AS PER SFBC 1507.2 (a)(3) � GARAGE No. DATE _ © �. N ° ' REVISIONS ..... I..... .................................................................................................................................................................1 BOTTOM LASS TEMP. rl€ I FOR INFORMATION ONL' I - n NOT FOR CONSTRUCTIOI GENERAL NOTES: I 0 1 j I °I n NOT FOR PERMI 1. BATHROOM FLOORS AND BASE TO BE OF IMPERVIOUS 6. REFER TO FOUNDATION PLAN FOR CONCRETE FILLED MATERIAL AS PER SECT. 1408.2 (B) S.F.B.C. BLOCK CELL LOCATION, SIZE AND REINFORCING. € n FOR PERMI € I d- 2. IN AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE € I INSIDE, THE MODE OF OPERATION SHALL NOT REQUIRE 7. ALL FIXED GLASS PANELS SHALL BE 3/16" SAFETY GLASS. DRI € € ................. ......................................................._............. ................................................................................ I - THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR ` m EFFORT. SUCH CLEAR OPENING SHALL BE NOT LESS THAN 8. ALL GLASS USED INSIDE DWELLING SHALL BE TEMPERED. 20" IN WIDTH, AND 24" IN HEIGHT, 5.7 SQ. FT, IN AREA i I 9. CAT. II SAFETY GLASS SHALL BE USED AT ALL SHOWER I _ 6 AND SHALL ALSO MEET THE PROVISIONS OF SECT. 1305. € I AND TUB ENCLOSURES INCLUDING WINDOWS WITH SILLS � � THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN LOWER THAN 60" AND MIRRORS IN THE TUB € j I I W 44" ABOVE THE FINISHED FLOOR AND NO PART OF THE I I `r OPERATING MECHANISM SHALL BE PLACED HIGHER THAN W d 10. WINDOW SILLS AT 2nd. FLOOR SHALL BE 36" MIN. A.F.F. Cr 54' ABOVE FINISHED FLOOR. 3. NUMBERS OF ADDRESS SHALL BE PLACED VISIBLE AND 11. NO ELECTRICAL, MECHANICAL, OR PLUMBING EQUIPMENT Lu c SH 36 W/ ARCH HR D25 ARCH L_I LEGIBLE FROM THE STREET FRONTING THE PROPERTY SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION HGT. 84G.D002 +46 OR 49 5 44.5 -47.4 � � AND SHALL BE 3 INCHES MIN. IN HEIGHT. +44.8 -57.9 4. TOILET ROOMS SHALL COMPLY WITH SECT. 1405.2b S.F.B.C. ZONE 5 ZONE 5 ZONE 5 ZONE 5 a 0 M 5. ALL WATER CLOSETS, LAVATORIES, SHOWERHEADS, AND 2'-8" 16'-0" 2'-8" 7�-1 pf, 4' 6' 4" '-4" 11'-8" 2'-0" W cn `n SINKS SHALL COMPLY WITH TABLE 46-R2 SFBC 1994 ED. w d- a LL 21'-4" 3'_g" g'_1" 7'_2>' ti ' Z r t v(D C° J GARAGE NOTES: .'•y Zy Ln, a rf 21'-4'0 8'-6 20'-0" 1. PROVIDE 1-HR. FIRERATED ENCLOSURE AS FOLLOWS 2. CONTRACTOR-SHALL POST PERMANENT SIGN WITH 1/2" PARTITIONS: LETTERS ON THE INSIDE FACE OF ANY ONE DOOR TO 49'-10 tip s:m„_ THE OUTSIDE READING: t, (TEST N0. WP 1200 FIRE RESISTANCE DESIGN MANUAL) � DANGER! DO NOT OPERATE ENGINES WITH DOOR �t:,: t(%)ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD OR VENEER CLOSED: CARBON-MONOXIDE EMISSION IS LETHAL. f 0 BASE APPLIED AT RIGHT ANGLES OR PARALLEL TO EACH SIDE OF 3-5/8" METAL STUDS 24" O.C. WITH 1" TYPE 'S' CO C� d DRYWALL SCREWS 8" O.C. TO VERTICAL EDGES, TOP, AND �' - U � � d BOTTOM RUNNERS AND 12" O.C. TO INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24" O.C. 3. PROVIDE SCREENED OPENINGS OR VENTS, THROUGH m Ld EACH SIDE. (NLB) & R-11 INSULATION BETWEEN STUDS THE GARAGE DOORS FOR VENTILATION AT OR NEAR a, U, � THE FLOOR LEVEL, THE CLEAR OR EFFECTIVE AREA Ln J - CEILINGS: OF WHICH SHALL NOT BE LESS THAN 60 SQ. IN. PER M d (TABLE 37C #42 S.F.B.C.) MOTOR VEHICLE ACCOMODATED. of < d 1" X 3" FURRING 16" O.C., 1 LAYER OF 5/8" TYPE NOTE: REQUIRED VENTS SHALL BE LOCATED WITHIN SHEET DESCRIPTION 'X' GYPSUM LATH, 5d CEMENT-COATED OR RING 7" OF THE HIGHEST POINT OF THE GARAGE FLOOR. SHANKED NAILS 6" O.C., PAPER TAPE EMBEDDED FLOOR IN CEMENTIOUS COMPOUND OVER JOINTS, 4. INTERIOR SIDE OF GARAGE MASONRY WALLS TO BE PLAN EXPOSED NAIL HEADS COVERED WITH COMPOUND STUCCO FIN. AND PRODUCT APPROVED INSULATION OF FIBERGLASS, OR MINERAL WOOL OR CELLULOSIC INSULATION HAVING A MINIMUM INSULATING VALUE OF R-11 SCALE FLOOR PLAN - 1 /4 " 1i4') PROJECT NUMBER 2000 DATE SHEET NUMBER A -