00-0530-007
Ln BATTERY 11.- Duct detectors shall be provided for systems above 2000 cfm in the BACKUP CA L CULA TION SPECIFICATIONS FIRE ALARM SYMBOLS FIRE ALARM SYSTEM downstream supply air ducts and in the air return dud for systems SEQUENCE OF OPERATION 1.- The Fire Alarm System design for the Seventy Six Hundred Building, recirculating over 15,000 cfm and serving more than one floor as per (NEW FACP) Suite 306 located at 7600 Red Rd. Miami,Florida 33143 NFPA 90A article 4-4.1. Activation of a duct detector shall SYM DESCRIPTION DEVICE produce a shut down of the air handling units. INITIATION DEVICES MAKE Automatic response functions shall be initiated only by the first fire alarm received. -- - 2.- All equipment shallbenewandU.L Listed. STAND-BY MODE Additional alarms shall be received, annunciated and shall initiate functions associated DO Duct detector System Sensor model#DH100ACDC DEVICE UNIT QTY TOTAL L E o exclusively with subsequent alarm. Common alarm function shall not be initiated unless 3.- The installation of the Fire Alarm System shall also comply with the the first alarm is returned to normal. NFPA-70 National Electrical code(NEC) 1996 edition and the Florida ANNUNCIATORS amps am S Accessibility Code For Building Construction 97 edition. The FACP 0.100 1 0.100 E The actuation of the fire alarm initiating device shall automatically initiate the function installation shall also comply with NFPA-101 and NFPA-72. FACP FACP Fire Alarm Control Panel AlarmNet model# 772OULF Duct Detectors 0.015 16 0.24 detailed below. 4.- The Fire Alarm System shall consist of an Automatic Fire Detection Total 0.34 LO LO and Notification System. The Fire Alarm System shall be an OTHER n N AlannlVet 772ouLF fire alarm system. 0.34 amps x 60 hours = 20.4 Amp-Hour required by battery � A.- DUCT DETECTORS EOL EOL End of Line Resistor Q Activation of Duct Detectors shall initiate the following functions: 5.- All Fire Alarm equipment for this project shall be rated " POWER S.- U LIMITED° BATTERY BACKUP CALCULATIONS c1) 1.- Indicate the location of the device by zone at the Fire Alarm Control Panel. 6.- The Fire Alarm Control Panel shall have standby battery backup as ALARM MODE 2.- Generate an audible alarm signal at the Fire Alarm Control Panel. per NFPA 72, 1996, Article 1-526 providing battery power DEVICE UNIT QTY TOTAL � 3.- Initiate air handling unit shut down. ca acf for the entire system to operate for 60 hours in normal mode and then, at the end of the period, for 5 minutes in the amps am S emergency mode 0.900 1 0.900 . FACP U j The maximum time period from actuation of the initiating device until initiation of all Duct Detectors () 0.07 2 0.14 related functions as listed above shall be ten seconds. 7- Cable size shall comply with article 760-71 and the cable installation Total shall comply with the separation and use of conductors and 1.04 cables as specified in articles 760-54 and 760-61 of the National (1. Only 10% as per des 04 amps x .0833 hours =criteria= 0.0866 Amp-Hour required by battery - ALL INDICATING CIRCUITS S HALL BE CLASS B Electrical Code. 1. ALL NOTIFICATION APPLIANCE CIRCUUTS SHALL BE CLASS B, STYLE W 8.- Building wiring shall specifically conform with the National Electrical Code article 760 part C for Power-Limited Fire Protection Signal Total battery Capacity for 60 hours = 20.4 + 0.0866 = 20.50 Amp-Hours THE BUILDING IS NOT SPRINKLERED Circuits with emphasis on article 760-52(b)on Power Limited Wiring Methods and Materials. Provide 2 : 12 Amp-Hour batteries 9.- MINIMUM CABLE SIZE. A.- #16 A WG Copper(24 16 FPLP)for:Smoke Detectors,'Duct Detectors, Pull Stations, Water and Tamper Switches. 10.- All new wiring installed in ducts, plenums and other spaces used for environmental air shall be type FPLP, as per NEC (National Electrical Code)article 760-61. DISTRIBUTION OF ZONES ZONE TYPE ZONE DESCRIPTION 1 Duct Detectors First Floor 2 Duct Detectors Second Floor 3 Duct Detectors Third Floor 0 4 FACP (existing) Alarm Output of existing FACP 5 FACP (existing) Trouble Output of existing FACP 6 - Not Used 7 - Not Used - Q0 8 - j Not Used O M k o r-) (D L; W d- U� z � z - .It . 0 x ta �. 41E' IV T EXISTING FACP TROUBLE OUTPU ;t moo' m YIr.� 0 is DAT Q0 T EXISTING FACP ALARM OUTPU ' I�}�w17 ��R�Anl-"P-DA SYS�'�I}';�^'M T'U�B��E7�� i S St�S�.iS'D IN A CC'..lLFD,,k1\TCL' N V f.J 1.1 7 2;70; 101=7.6 0 . Eon D16 D15D14 D13 . NOTE : INTERCONNECTION OF FACP ' S SHALL p��}y ��-`yyLLUNIN � FE S-A t;j'�ArI �A . li-��y/ �'�'!d ll�k�/��'Y lkYl7 LLf"G LJ!'El��� c{:iZll ld�I� COMPLY WITH NFPA-72 ARTICLE 1 -5 . 8 8c 3-1 1 5 ����o�,>iDED A�r 1-u�icot� oc:' P,�N.,r! y� S U"L L ' Eon D D D D D D7 D6 D5 10 9 8g 1 2 1 1 k ,W: 2 # 16 FPLP MIAMI-I)ADE CO. $3to T�-c 1r `. APPLICATION ��r C© ISSUE DATE: 10/12/99 Eon D D D D 4 3 2 1 Scale: 1/8"= T-0" DRAWN BY: CHECKED BY: INPUT 24VoIt _ FIRE ALARM CONTROL PANEL NOTE : EXTENT OF THIS PROJECT IS FOR DUCT DETECTORS ONLY . F RE ALARM R SER AZ TOMAS C. ARfAST.RO?SV17F7A. ENGINEERING C04 r,ANTS `W# 55 AVM 5600 S.W. 135th Ave. . 211, Micmi FC1 31 3., SHEET NUMBER , Tel (305)386 7152 Fox 366 Z15yj 7rd A�A ¢o ru _ ` r TOMAS C. ARMSTRONG, FA - 7 a E.E. PE-17974 Odf��'� d••