00-0061-026 REVISIONS BY
°
CAP FOR FUTURE PLUI"15ING FIXTURE 6CI4EDULE
Z CONNECTION SOLAR DUL E
_ <
OR HEAT RECOVERY TRAP FIXTURE HOT COLD - °
HEAT TRAP MARK (n SIZE UNITS WATER WATER MANUFACTURER NOM. NOM. ESP IN. ELECT. TOTAL COOLING CAP. 3/T O/A DIMENSIONS WEIGHT ^cl-.ACT. 5Ef2VIC�
UNIT AND MODEL NO. TONS CFM WG. HEAT KW FLA/HP BTUH 6 950 8 67? W CFM WxLxH (IN.) LBS. VOLTS/PH/Hz SEE
GATE vALY GATE VALVE WC 3" 4 - viz" - W
A42 RBHA21J11SUGAI 1400 .40 10 3 3/1/z 21 x 23.5 x 52 150 20 =230/1160^ 12.4 3
HEAT TRAP LAV 11/4 1 z z
COLD WATER, 3/4" CU RHEEM 3,5 1-1.9 29,300/41,000 3(o x 40 x 43 313 205-230/1/00 "
1$2 RAM5042JAZ Z
H.W. TO FIXTURES SH 2" 2 1/21, '/2" o
HOT WATER, 3/4" UNION S< 1 viz 11 2 viz 11 '/2 " W 00 LZ
o
WM 2" 4 >/2 ,,z N 0) 0 0 3
PRESSURE 4 TEMPERATURE r I 0) •b
RELIEF VALVE (ASME APPRVD.) DW 1�/ " SW 2 �� „ _ NOTES:
z z = n � 0 N `
'i2 " W/VAL VE Ln 1 0
O °
11 NB - - - VAC. BREAIGER Q LO Lo
3/4 Cu RELIEF DISCHARGE V) �_ 0 W
ELECTRIC LINE, TO OUTSIDE GREEN TUB 2" 2 'iz" '/2" W r� � W
AREA, TERMINATE ro" `' z
00 G;ALR ABOVE FIN. GRADE BD 211 1 viz" '/2" = -1 O U
2-6.0 KW W _:I
EF-.89
FAN SC+�EDULE 0 0
DRAIN VAL 1) FIXTURES TO COMPLY W/SFBC TABLE 46-R-2 z Q CL Q
MANUFACTURER ELECT. SERVICE DIMENSIONS WEIGHT 0 :�i W L- 0
FAN AND MODEL NO. RPM HP CFM 8 S.P. VOLTS/PH/Hz WxLxH (IN.) LBS. REMARKS J U sy
2) ALL SHOWERS 4 BATH/SHOWER COMBINATIONS SHALL W
BE PROTECTED WITH A CONTROL VALVE OF THE W/ GRILLE, 3"o DUCT 0 I-
EX. FAN NUTONE C35OG 1500 1/90 50 a 1/S 115/1/�O 9 X 9 X 4 (0
°
PRESSURE BALANCE, THERMOSTSTIC MIXING OR COM-
8 ROOF CAP
BINATION TYPE. HANDLE POSITION STOPS MANUFACTURER'S a
INSTRUCTIONS AT TIME OF INSTALLATION TO A MAXIMUM
Z
�A T fR H A T � F I F IN D 1 A��A� MIXED WATER OUTLET TEMPERATURE OF 120° F. S 13 311 H O d d :
O o
NO SCALE O
Z
AIR COND IT ION ING S�'STEM - GENERAL NOTES: O N
RIGID FIBERGLASS DUCT (R-6) -' cc
I. DUCTWORK SHALL BE 1 1/2" THICK, 3 POUNDS PER CUBIC FOOT DENSITY Z
PLUMBING GENERAL NOTES AND SPEC IF IC,4T IONS: FIBERGLASS WITH VAPOR BARRIER, UNLE55 OTHERWISE SPECIFIED. ~
DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE O 3
WITH MANUFACTURER'S SPECIFICATIONS AND ACCORDING TO "A5HRAE" V�
1. A. SCOPE OF WORK: AND "SMACNA" STANDARDS. Z
SPIN COLLAR DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND TO INSIDE
DIMENSIONS WIDTH X HEIGHT. DUCT SYSTEM SHALL COMPLY WITH °
THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY SHOWN ON THE "NFPA" STANDARD NO. 90A AND/OR 908. DUCTWORK AND COMPONENTS N
DRAWINGS, SPECIFIED HEREIN AND/OR AS NEEDED FOR A COMPLETE 11 i SHALL BE CLA55 I MATERIALS IN ACCORDANCE WITH U.L. 181
SYSTEM, INCLUDING BUT NOT NECESSARILY LIMITED TO: TESTS. o
T
1. DOMESTIC COLD AND HOT WATER PIPING SYSTEMS 2. COORDINATE LOCATIONS, SIZES AND OPENINGS WITH OTHER TRADES a
O
ON THE JOB. A/C CONTRACTOR SHALL PROVIDE THE COMPLETE DUCT
2. SANITARY DRAIN AND VENT SYSTEMS SYSTEM WITH TURNING VANES AT ALL ELBOWS, SPLITTERS AND o
3. PLUMBING FIXTURES AND TRIM DAMPERS, AS REQUIRED. V
4. AIR CONDITIONING CONDENSATE DRAINS A/C CONTRACTOR SHALL USE THE BEST PRACTICES OF THE TRADE IN W % 3
5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER THE FABRICATION AND INSTALLATION OF THE SYSTEM.
O
ro. PIPING INSULATION INSULATED FLEXIBLE DUCT GLASS 3. DIFFUSERS SHALL BE SELECTED, LOCATED, AND BALANCED IN ORDER Q
-1. SUPPORTS AND HANGERS 11/2" WITH POLYETHELENE JACKET THAT THEY DELIVER THE REQUIRED CFM TO THE ENTIRE ROOM EVENLY Q u- o
AND DRAFT FREE TO MAINTAIN THE FOLLOWING DESIGN CONDITIONS: }� �- - a
B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST AND STEEL WIRE REINFORCING -r o
INSIDE OUTSIDE RELATIVE }- ,
EDITION OF THE "SOUTH FLORIDA BUILDING CODE" CH. 4(o LOCAL ORDINANCES COOLING - 1�0° DB 91° 1:>5 - 19° W5 HUMIDITY Q
AND IN COMPLIANCE WITH THE "FLORIDA ENERGY EFFICIENCY CODE FOR HEATING - 10 DB 45° - DB 5096 TO 609. Q O Le
BUILDING CONSTRUCTION", AND "HRS" REGULATIONS. IN THE EVENT OF -1 cn °
CONFLICT BETWEEN ANY CODE OR REGULATIONS, THE MORE STRINGENT W J W
4. ALL FAN UNITS, MOTORS, COMPRESSORS, ETC. SHALL BE ISOLATED, W 0
REQUIREMENTS WILL GOVERN. DIFFUSER AS REQUIRED TO OPERATE QUIETLY SO THAT NOOBJECTIONABLE SOUND �-+ "► o
WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY, ♦I--11 a
2. CONTRACTOR TO VERIFY AT SITE THE LOCATION, ELEVATION AND SIZE OF ALL MOTOR HUM, VIBRATION, OR MECHANICAL MOVEMENT.
EXISTING LINES FOR CONNECTION BEFORE INSTALLATION OF ANY PIPING. O W X
5. A/C SYSTEM SHALL HAVE DISPOSABLE AIR FILTERS LOCATED AS -I W
3. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS REQUIRED FOR EASY ACCESSIBILITY. II ii
OR SHOCK ABSORBERS AS INDICATED ON PLANS. T*1'PICAL D IFFU5ER CONNECTION DETAIL 11-u-1G °LU
pW
4. PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH THE APPROVED MATERIALS NO SCALE
SHALL HAVE SMOOTH IMPERVIOUS SURFACES AND SHALL BE FREE FROM DEFECTS 6. A/C SYSTEM SHALL BE CONTROLLED BY A THERMOSTAT. MOUNT --Il O O
AND CONCEALED FOULING SURFACES. ALL FIXTURE TRIM TO BE CHROME PLATED. THERMOSTAT 5'-0" ABOVE FINISHED FLOOR, U.O.N. 0 °
0
FIXTURES SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC. 0 ZO O
1. ALL GRILLS AND DIFFUSERS TO BE OF ALUMINUM CONSTRUCTION. DIF- Q
5. WASTE LINES TO BE PVC SCH. 40. SLOPE ALL UNDERGROUND SANITARY PIPES AT 1/8"/FT. FUSERS SHALL HAVE HIDDEN OPPOSED BLADE DAMPERS. PROVIDE GASKETS H
ALL ABOVE GROUND WA5TE/VENT BRANCHES At 'i4"/FT SLOPE. ON ALL GRILLES AND DIFFUSERS. TITUS OR AIREGUIDE, FINISHED COLOR Z
- SUPPLY DUCT O � u.i
BY ARCHITECT. �}
6. PROVIDE FULLY ACCESSIBLE CLEAN OUTS ON SANITARY AND ANY WASTE PIPING AT
EVERY CHANGE OF DIRECTION, AND AT BOTTOM OF STACKS. CLEAN OUT LOCATIONS 8. UNDERCUT DOORS I" AFF., AS INDICATED.
AND SIZES ON HORIZONTAL LINES SHALL BE ACCORDING TO CODE. # - +~-t U Z
REFRIGERANT LINES _ 9. ALL REFRIGERANT PIPING SHALL BE COPPER - TYPE L - I ` _ Z
7. VENT LINES TO EXTEND 9" MIN. ABOVE ROOF AND FLASH WITH LEAD. �`� �'� ACR TYPE, DEHYDRATED AND SEALED. ALL FITTINGS SHALL BE U H W
TO OUTSIDE I i I
8. WATER PIPE BELOW GROUND SHALL BE COPPER TYPE "K" ABOVE GROUND TO BE CONDENSING UNIT I �� I WROUGHT COPPER. ALL JOINTS SHALL BE MADE WITH HIGH a Z H
COPPER TYPE "L". OR APPROVED CPVC OR POLYBUTELYNE AS REQUIRED BY OWNER �� -�� TEMPERATURE BRAZING ALLOY OF NOT LESS THAN 596 SILVER M N Z
PIPING INSTALLATION NOT LESS THAN 3/4 THICK ARMAFLEX .LIQUID AND SUCTION LINES SHALL BE SIZED ACCORDING TO Q
EQUIPMENT MANUFACTURER'S RECOMMENDATIONS FOR EQUIVALENT O w
11. PIPING LENGTH OF PIPING RUN FOR CONNECTED TONNAGE. ALL PIPING 3
ACCESSORIES SHALL BE CONSTRUCTED AS SUGGESTED BY EQUIPMENT ° H
A. SUPPORT ALL PIPE FROM SOUND PORTIONS OF STRUCTURE AND AT PROPER R/A - -� CEILING MANUFACTURER ALL PIPING SHALL BE EVACUATED PER GOOD
INTERVALS ACCORDING WITH CODE. I
PIPING PRACTICE BEFORE START-UP. a a
3/4" CONDENSATE I
B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION SLABS OR DRAIN w/ 3" TRAP I I MODEL A
MASONRY WALLS, CAULK OPENINGS BETWEEN PIPE AND SLEEVES. GREEN AREA PARTITION
TO I PARTITION a Lr(7I' 1
tq
C. WHERE EXPOSED PIPES PA55 THROUGH FLOORS, WALLS, OR CEILINGS, PROVIDE I I CONDENSING o Z
ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUTSIDE STL. A.N.U. SUPPORT I I UNIT j SCALE 1/4' = 1'-0"
DIAMETER TO COVER THE SLEEVED OPENINGS FOR THE PIPES. PROVIDE
CHROMIUM PLATED ESCUTCHEONS IN BATHROOMS. I I CHECKED BY M•G. o
NO COMBUSTIBLE
9. INSPECTIONS AND TESTS MATERIALS WITHIN i I = DRAWN BY C.Cx. N
A. CONTRACTOR SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS TO THE A.H.U. ROOM W
I (W/H UNDER) PIPE INSULATIO CONCRETE i DATE 02/01/00 W
AUTHORITIES HAVING JURISDICTION, AS THE WORK PROGRESSES. ALL
SYSTEMS SHALL BE TESTED BY CODE AND/OR LOCAL REGULATIONS. LOUVRE DOOR j j PAD N
o JOB 9(028 W
B. DRAINAGE PIPING: BEFORE INSTALLATION OF ANY DRAINS, THE ENDS OF I I FLOOR '� •' '• X
SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH THE WATER TO THE Li Li SHEET
La
HIGHEST POINT AND ALLOWED TO STAND UNTIL INSPECTION IS MADE BY AN
OWNER REPRESENTATIVE. POWER DRIVEN STUDS
OR LAG BOLTS W/SHIELDS I. W
Z
10. STERILIZE ALL WATER LINES WITH A MIXTURE OF TWO (2) POUNDS OF CHLORINATED TO WITHSTAND OVER 120 S OF SH ETS t W
LIME TO EACH 1.000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE). M.P.H. WINDS it
RETAIN MIXTURE IN PIPES 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER REFRIGERANT LINES
TO AHU IN PVC SLEEVE
BEFORE PLACING IN SERVICE. 4ry ' a.
11• COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN-SERVICE TEST AIR HANDLEIR UNIT
COND EN5 ING UNIT A
AFTER COMPLETION OF THE INSTALLATION.
INSTALLATION DETAIL IN&TALLATION DETAIL. GUERRERO/GONZALEZ
�+ NO SCALE ENGINEERS, INC. : FEB
NO SCALE Michael C. Guerrero, P.E. �' 410 { `f'�1
Mechanical Eng. Lic. /15235
GE ¢ <i
Rafael L. Gonzalez, P.E. x}t �• f"
Electrical Eng. Lic. #11057
11420 N. Kendall Dr., Suite 200
Miami, Florida 33176
Tel, (305) 595-8525, Fax (305) 596-9077 ARCR N 0 7 7 1 2