Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
00-0012-001
�n "n REVISIONS- RIM ^� &7nEcg9 CONSTRUCTION NOTES ^^^^ n (1) PROVIDE O TWO (2) 5ELF CONE PIS) ALUMINUM CYLINDER TI B PRO AIR FILL MALE ADAPTER. PROVIDE FACTORY FURNISHED OSHA-APPROVED CORROSION NOTEt�4 RESISTANT WALL- MOUNTED CASE. PROVIDE FACTORY-FURNISHED BREATHING TUBE QUICK-DISCONNECT ASSEMBLY. INSTALL BR1 AT+4ING NOTE 3 - APPARATI PER MANUFACTURER'S RECOMMENDATION. PROVIDE SIGNS, s =-----;_-:::::::::::::-:___:::::::::::::_::::::::::::::_:::::::::::::::::::�..__:::::__:::::::; LABELS AND INSTRUCTIONS PER ASHRAE 15 GUIDELINES. EACH BREOING APPARATUS SMALL COMPLY WITH ALL REQUIREMENTS OF -------------- :::::::::::=::::::===== OSHA, AN51\NFPA. NOTE EXISTING ca DEMINERALIZER N TO REMAIN W (2) PROVIDE MULTI-CHANNEL REFRIGERANT MONITOR WITH AUDIBLE ALARM, NOTEQ MR-18 ; rn TRANS MODEL RMWE OR APPROVED EQUAL BY BRASCH. THE MONITOR ----- (TIE) PROVIDE ,4 I 6 - i_ ::::::::::::::::::::.: -------------------:---- _ _ DOOR HOLDER SHALL BE CAPABLE OF MEASURING THE CHILLER'S ACTUAL REFRIGERANT - _-......'_________________� ------------------------ ------ --------------- ------------------------=----=------- BEING PROVIDED (RlI, R22 OR R-123) DOWN TD I PPM AND DISPLAYING ----, ...._=a_.. XI BOILERS EXISTING REFRIGERANT CONCENTRATION FROM 0-1000 PPM. PROVIDE FACTORY FURNISHED ; 0 T REMAIN. SIGNAL ALARM AT THREE DIFFERENT CONCENTRATION LEVELS. PROVIDE ; ; o ~i* �o FACTORY FURNISHED CLEAR LANGUAGE DISPLAY OF ALL SETUP ALARMS, EXISTING SST ' - .......•.------. .................. r--� I I DIAGNOSTIC MEASURED CONCENTRATION AND CALIBRATION COMPRESSORS I , , L_ FAN EF-9 ON iNFDRMAT1C1�1. PROVIDE SIGNS, LABELS, AND INSTRUCTIONS PER NOTE(E) ROOF ABOVE ® NOTE t4 I L J TO REMAIN. �1� $ o m ASHRAE 15 GUIDELINES. tNOTE t I INTERLOCK WItN I I I �� �i.�.co (3) CONTRACTOR SHALL PROVIDE A LEGIBLE PERMANENT SIGN PER ASHRAE i i eM\z IXISTIIdC, DcISCIMG t SE X.1 REFRIGERANT MONITOR i i i ===. V- c IS GUIDELINES. soo TON 250 TON ; 5Q0 TON AMR-20 I I I =�• a O0 0 LJI 04ILL ER s C4ItLLER I s ' 04ILLER ° n i i TE t f...... �.E NOTE i NOTE (4) PROVIDE V4 ROUND SAMPLE TUBE. FIELD VERIFY THE LOCATION. I I , ,TERMINATE SAMPLE TUBE PIPE iB" AFF WITH FACTORY FURNISHED �_______� �__� (q) (q) (q) I I PARTICLE FILTER. CO-ORDINATE PIPE ROUTE WITH EXISTING EXISTING :___� OVERHEAD DOOR WILL BE INSTALLATIONS, INSTALL SAMPLE TUBE PER MANUFACTURER'S PANEL "W" EXISTING REFRIGERANT MONITOR CLOSED ON ALARM MODE RECOMMENDATIONS. TRANSFORMER TO REMAIIN INTER ELOCK o o°©��®�O� NOTE (tl) (5) PRIOR TO OPERATION OF EQUIPMENT, CONTRACTOR SHALL FURNISH A EXISTING WITH REFRIGERANT MONITOR COPY OF THE EMERGENCY SHUT DOWN PROCEDURES TO THE AUTHORITY PANEL 'MW Seal: ►. $, HAVING JURISDICTION. THE EMERGENCY SHUT DOWN PROCEDURES SHALL - ::::::::::::::::::. _ - ..- - - - - - 1 ADDRESS THE FOLLOWING: � A INSTRUCTION FOR SHUTTING DOWN THE SYSTEM IN CASE OF EMERGENCY. H THE NAME, ADDRESS, AND DAY AND NIGHT TELEPHONE f 5 ' NUMBERS FOR OBTAINING SERVICE. EXISTING CONDENSER U- FOR NOTE® G THE NAME ADDRESS, AND TELEPHONE NUMBERS 0 ALL WATER PUMP REFRIGERANT ER F MONITOR POWER = CORPORATE, LOCAL STATE, AND FEDERAL AGENCIES TO BE } CONTACTED AS RRUIRED IN THE EVENT OF A REPORTABLE I;�I INCIDENT. (6) CONTRACTOR SHALL PROVIDE A DATED DECLARATION OF TEST PER _ ASHRAE 15 SECTION I.B. THE DECLARATION SHALL GIVE THE NAME OF NOTE(3 REFRIGERANT THE FIELD TEST PRE55URE APPLIED TO THE HIGH5 OF ' i ANY DOWNSIDE OF THE SYSTEM. WHEN REQUESTED CONTRACTOR SHALL I � r"r`°:���r x o PROVIDE THE SIGNED DECLARATION TO THE AUTHORITY HAVING ` _ — Ey 1 I JURISDICTION. EXISTNG (7) CONTRACTOR SHALL PROVIDE REFRIGERANT MONITOR ALARM SCHEDULE. i CC14ILLL R THE SCHEDULE WILL INDICATE THREE ALARM LEVELS OF 30 PPM 500 l_._ NOE PPM, AND 1000 PPM, AND DISPLAY ALARM STATUS I.E. LOW ALARM (q) LEVEL SHALL INITIATE VENTILATION SYSTEM, HIGH ALARM LEVEL ------------- SHALL INITIATE AUDIBLE ALARM AND CAUTION A POTENTIAL OCCUPANT oTE(� Q OF POSSIBLE LOW LEVELS OF OXYGEN WITHIN THE ROOM. NOT I I I E I { 0 (8) PIPE INLET FOR CONTROL COMPRESSOR TO OUTDOORS. ~--- �- 1 r r l - r �� q(y1��r-� fib s ;, I I 1 •- 5/ €i ......... -- `------ (q) CONNECT PURGE UNIT TO RELIEF PIPE AND ROUTE TO OUTDOORS 101-011 j 4 ---. -_.� r_:_._.::::::::::::..::....:...:::::..::::::::________________________::: y --------------------- FROM ANY AIR INLET TO THE BUILDING. ', », 1. !:i''. I'' :t I I " 1 ; , JL.._._. (10) PIPE AIR INLET TO OUTDOORS. I �__. NOTE t NOTE(! (11) RETROFIT MOTOR DRIVE ON OVERHEAD DOOR. INCORPORATE OBSTRUCTION-SAFETY ._______.. -_-..---T..... _ NOTE(F�3 OPTICAL SENSORS AND FORCE FEEDBACK SENSORS ON OPERATOR MECHANISM. DOOR SHALL BE-CONFIGURED TO CLOSE ON SIGNAL FROM THE REFRIGERANT MONITOR. (12) CONNECTIONS TO REFRIGERANT MONITOR SHALL RETAIN THE NEMA 4 INTEGRITY OF THE ENCLOSURE. SIGNAL TOWER SHALL BE WEATHERPROOF AND SHALL BE MOUNTED IN A REMOTE LOCATION AS INDICATED. EXTEND CIRCUIT USED FOR REFRIGERANT MONITOR'S POWER CONNECTION, AND PROVIDE CONTROL j�T - '�� .op '�' MECHANICAL PLAN ®1 RELAY WIRING BETWEEN REFRIGERANT MONITOR AND SIGNAL TOWER. SCALE: 11W - 1'-0' (13) PROVIDE INDUSTRIAL CONTROL RELAY WITH FIVE NORMALLY OPEN CONVERTIBLE CONTACTS, 20 AMPERE CONTINUOUS CURRENT RATING, 120V. Q '� �X) F� Z A.C. COIL, N MA I NC L, E ENCLOSURE. COIL SHALL BE ENERGIZED BY ` RELAY CONTACT LOCATION IN REFRIGERANT MONITOR AT LOWEST ALARM J (L LEVEL. THIS RELAY SHALL HE USED TO STAR EXHAUST 4 T EX T FANS, GLOSS DOORS, ACTIVATE FLASHING LIGHTS AS PER NOTE 31 IN CASE OF REFRIGERANT LEAK. Cf) EXTEND (2) #12 IN 1/2"C, J co (14) PROVIDE FLASHING BEACON LIGHT WITH PROTECTIVE DUST COVER IJJ (WEATHERPROOF COVER FOR OUTDOOR LOCATIONS) 2514-120V LAMP, RED - u LENS, WALL MOUNTED ABOVE DOOR LEVEL, TO BE ACTIVATED BY _ - REFRIGERANT MONITOR'S CONTACT" AT LOWEST ALARM LEVEL. TIE -- _ TO CIRCUIT SERVING REFRIGERANT MONITOR AND CONTROL TOWER, AND PROVIDE CONTROL WIRING AS REQUIRED. TYPE: EXISTING PANEL BOARD MAINS: AS NOTED BELOW � MOUNTING: SURFACE PANEL =Wll BUS RATING: 100A. � M A.I.C. EXISTING VOLTAGE: 1201208V., 3PH,4W CIR NO. OF TRIP VOLT DESCRIPTION -WIRE& CIR NO. OF TRIP VOLT DESCRIPTION WIRE & - r 'Q N0. POLES AMPS. CONDUIT N0. POLES AMPS. CONDUIT L 1 1 20 1000 EXISTING CIRCUIT EXIST 2 1 20 300 SPARE --- ap 3 1 20 1000 EXISTING CIRCUIT EXIST 4 1 20 300 SPARE _ ASHRAE-15 CALCULATION 5 1 20 1000 EXISTING CIRCUIT EXIST 6 1 20 300 SPARE ---Q=100 X G 0'5 „ " 7 1 20 1000 EXISTING CIRCUIT EXIST 8 1 20 300 SPARE Fm ® Q EXISTING PANEL HM EXISTING PANEL "MR” 9 1 20 1000 EXISTING CIRCUIT EXIST 10 1 20 300 SPARE - Q=AIRFLOW TO REMAIN --- ti G=MASS OF REFRIGERANT (POUNDS) 11 1 20 1000 EXISTING CIRCUIT EXIST 12 1 20 300 SPARE --- IN THE LARGEST SYSTEM 13 1 20 1000 EXISTING CIRCUIT EXIST 14 1 20 300 SPARE --- 750 TON CHILLER: 2140 POUNDS OF RI23 15 1 20 1000 EXISTING CIRCUIT EXIST 16 1 20 300 SPARE --- Q=100 X 2140 0.5 17 1 20 300 SPARE EXIST 18 1 20 300 REFRIG. MONITOR&CONTROLS #12, 1/2" woo EXISTING i5KVA 19 20 1 20 1200 OVERHEAD DOOR MONITOR #12, 1/2" j Q-4626 CFM TRANSFORMER 21 3 100 --- MAIN BREAKER SEE RISER 22 1 20 1000 EXISTING CIRCUIT EXISTING AIR EXHAUSTED: 23 24 1 20 1000 EXISTING CIRCUIT EA STI NG Project No. 8000 CFM 25 26 970430 27 28 Date: 02ND V99 FLOOR EXISTING (4) #3 IN f I/4"C 29 30 Designed by. TO REMAIN. VERIFY r-ONDITION 31 32 AFF EXISTING FEEDERS - t IMPLEMENT REPAIRS/ENHANCEMENTS 4 OVERGURRENT AS REQUIRED. 33 Drawn .by. PROTECTION ON 35 36 JAD PRIMARY SIDE LEX15TING #B IN I/2"C TO 37 38 Approved: TO REMAIN COLD WATER PIPE, BUILDING 39 40 AFF SERVICE GROUND AND BUILDING 41 42 Scale: STEEL. VERIFY CONDITION * SUB-TOTAL 8300 5900 AS SHOWN IMPLEMENT REPAIRS/ENHANCEMENTS SUB-TOTAL 5900 AS REQUIRED. TOTAL 14200 (CONNECTED LOAD) DEMAIND = 14.2 KVA- 39.4 A MEml ELECTRICAL RISER DIAGRAM N.T.S. \z'