00-1294-014 I I I D E F G H I J K L M N 0
I I ( I I I I I I I I
(
REFURBISH EXISTING TRENCH
DRAINS - CLEAN OUT TRENCH,
+ REPLACE CQVER
! I
-------\IukicEXISTING SCREEN +
FINISH SCHEDULE
FRAMING TO BE REMOVED FLOOR WALL-N WALL-E WALL-S WALL-W CEILING
EXISTING STEEL COL EXISTING LOW BLOCK
ROOM J J = REMARKS g ® s
_ _ _ _j i.
a z ¢ z ¢ o
! TO BE REPAIRED WALL TO BE REMOVED ! m LL 92
! i
NEW ROOM CT* CT* DW P DW P DW P DW P DW 8'-2"
EXISTING 116 ALHAMBRA CIRCLE SUITE J
! ! VESTIBULE CT CT DW P DW P DW P DW P DW 8'-2"
SCREENED PORCH
- •' � DEN CT CT DW P DW P DW P DW P DW 8'-2"
CORAL GABLES, FLORIDA 33134
BATH CT CT DW P DW P DW P DW P DW 8'-2" E-mail : bap @bapdesign.com
2 I
—2 Florida Corp AA0002364
PH 305.444.7100 FX 305.444.9803
EXISTING DOORS EXISTING DOORS
+ FRAME TO BE + FRAME TO BE C _ CARPET Copyright @2000 By:Beanie Archiwturd Putership,P.A.
REMOVED REMOVED SV1 - SHEET VINYL FLOOR
CS - CONCRETE SEAL VB - VINYL BASE
EXISTING CT - CERAMIC TILE WB - WOOD BASE
BEDROOM DW - DRYWALL
EC - EXPOSED CEILING NOTE: REFER TO SHT. A1.02 FOR COLORS AND MATERIALS
EXISTING FRP - FIBERGLASS REINFORCED PANELS
3 — BEDROOM EXISTING
RN TO REMAIN
P - PAINT
* - TO MATCH EXISTING
—3
EXISTING EXISTING
LIVING ROOM FAMILY ROOM
EXISTING DOOR TO. BE EXISTING WINDOW + -
REPLACED. CUT EXISTING CASING TO BE REMOVED I DOOR AND F'RAME' SCHEDULE' '
EXISTING DOOR + FRAME OPENING HIGHER TO EXISTING SPRINKLER DOOR pRA1yq�
TO BE REMOVED ACCOMODATE NEW DOOR PUMP TO BE RELOCATED I I
AT NEW RAISED FLOOR ( I
4 — f-- -- EXISTING ELECTRICAL
A/C A/C PANEL TO BE REPLACED I ao —4 Lu
?' EXISTING WATER HEATER,
WASHER + DRYER TO EXISTING DOOR, TRACK
BE RELOCATED + FRAME TO BE 1 WOOD FRENCH/HINGED 5'-0"x6'-8" PREFINISHED WOOD PREFINISHED METAL ANDERSEN FWH 5068-APLR
EXISTING AHU EXISTING iir---� i REMOVED 2 WOOD FRENCH/SLIDING 9'-10"x6'-8" PREFINISHED WOOD PREFINISHED METAL ANDERSEN FWG 10068-4
Q Q TO BE REPLACED KITCHEN 00 : ! 1 I
EXISTING X11 I 3 WOOD FRENCH/SLIDING 9'-10"x6'-8" PREFINISHED WOOD PREFINISHED METAL ANDERSEN FWG 10068-4
DINING AREA 0 0 '��� ! 4 WOOD FRENCH/SLIDING 9'-10"x6'-8" PREFINISHED WOOD PREFlNISHED METAL ANDERSEN FWG 10068-4
EXISTING 100
ri EXISTING 5 WOOD FRENCH/HINGED 5'-0"x6'-8" PREFINISHED WOOD PREFINISHED METAL ANDERSEN FWH 5068-APLR
MASTER BEDROOM Q 00 ' DO I I �WH f GARAGE I "
L _ J --_- 6 WOOD FRENCH/HINGED 2'-6"x6'-8 PREFINISHED WOOD PREFINISHED METAL ANDERSEN FWH 2768-AL
5 7 WOOD FRENCH/HINGED 5'-0"x6'-8" PREFINISHED WOOD PREFINISHED METAL ANDERSEN FWH 5068-APLR
—5
EXISTING WALL, DOOR. I I 8 WOOD BI-FOLD 6'-0"x6'-8" PAINTED WOOD PAINTED NONE FULLY LOUVERED
Q EXISTING WINDOW + I I
DOOR FRAME. + PLUMB- CASING TO BE REMOVED 9 S.C. FLUSH HINGED 2'-6"x6'-8" PAINTED WOOD PAINTED NONE
ING FIXTURES TO BE
BATH REMOVED 10 WOOD BI-FOLD 6'-0"x6'-8" PAINTED WOOD PAINTED NONE FULLY LOUVERED
11 S.C. FLUSH HINGED 2'-4"x6'-8" PAINTED WOOD PAINTED MARBLE
Lu E EXISTING TO REMAIN
EXIST11m
DEMO PEA
6 -- ASCALE: 1/4"=1•'_0"
WINDOW SCHEDULE —6
A-4
88'-4"
30'-1" 22'-8"
1 ALUMINUM SINGLE HUNG 3'-3"x3'-2" PREFINISHED PTD. WOOD PGT #3433 ;
9'-10" R.O. 2" 9'-10" R.O. 2" 9'-10" R.O. 1'-1
2 ALUMINUM SINGLE HUNG 3'-3"x3'-2" PREFINISHED PTD. WOOD PGT #3433
4" " 5 7-,A- " "
3 ALUMINUM SINGLE HUNG 4'-0"x3'-2" PREFINISHED PTD. WOOD PGT #4033
7 —
5'-9" 5'-3" 5'-6" 5'-6" 5'-3" 5'-9"It 4 ALUMINUM SINGLE HUNG 4'-0"x3'-2" PREFINISHED PTD. WOOD PGT #4033
4 s i 02 i 03 04 I —7
_•_-_- __ ! _ E EXISTING WINDOW TO REMAIN
12E NEW CONC. COLUMNS.
01 A-4 SEE FOUNDATION PLAN
05
o Z NEW SLAB OVER It
N EXISTING `. °I WALL HATCH LEGEND
8 — EXISTING WALL TO REMAIN
g FRAME OUT EXISTING A2 3 —8
N POCKET, WALL + HEADER NEW FRAME WALL. EXISTING WALL TO BE
TO BE FLUSH W/ ADJACENT
SEE SECTION REMOVED
• z -----------WALL '
- -------------- • R
' NEW INTERIOR PARTITION NUMBER. DATE rrEM:
Lij REVISION
o - -- ---
. • . . . , .• •.• -.•.•.-7L+ NEW EXTERIOR STUD WALL
NEW EXTERIOR BLOCK WALL GAR C IA RESIDENCE
9 —
EXISTING °D NEW POURED CONCRETE —9 RENOVATIONS
BEDROOM
FABRIC AWNING " '-
EXISTING O z
10 -11
BEDROOM —
EXISTING EXISTING BOXED HOUSING MADE OF P.T.
LIVING ROOM FAMILY ROOM PUMP.WELLGHEAD, + ATTACHED 5870 SW 85th STREET FT
06 I I 07 I PIPING
DESIGN WND PRESSURES FOR SOUTH MIAMI DOORS AND-WINDOWS.
8'-3" 5'-6" 4" 7'-3" o
10—
REPLACEMENT ELECTRICAL PANEL REF. �i R+S-�—c�
a TRIBUTARY AREA WIND PRESSURE (P.S.F.) FLORIDA
SURFACE-MOUNTED ON BLOCK VESTIBULE 2 -0" :C (SO. FT.) —10
EXISTING CLOSET TO BE `'' DEN 08 d,
WALL. FUR OUT WALL FLUSH W/ In
REFURBISHED: PATCH, INTERIOR ZONE CORNER ZONE
O FACE OF PANEL 5 -7 2 13 -1 ,,,,. •i" ` -*.,,,,
REPAIR & PAINT WALLS & � " " cv "
CEILING. REMOVE SILL AT
DOOR AND INSTALL NEW 09 NEW CONC. TOPPING SLAB <10 - +4 - P
6'-8" FLUSH S.C. DOOR, REPLACE EXISTING NEW SLAB OVER EXISTING W/ 6"X6 01 +45, 48 5, 62 r -
WIDTH TO MATCH EXISTING. A.H.U.
#10/10 W.W.F. ON 6 MIL
INSTALL NEW FLOORING TO 2' 2" VAPOR BARRIER. NEW FINISH
MATCH HALL. INSTALL 5 BLOCK IN EXISTING 10 TO 20 +42, -45
WIRE SHELVES.
;2 -0 'tW HOUSE FINISH FL00 0/H DOOR OPENING : Y • b °
EXISTING E UPPER + LOWER H " W/ 8" BLOCK. PRO- N _ -'• i - •. . ;
CABINET + COUNTER : S ELF ® 5 0 VIDE FILLED CELL COL- 1 20 TO 30 +42 -45 +42 -56
UMNS AS SHOWN- 4 O.C. c� •j .�3;�,�'`.,
DINING AREA EXISTING TOP 01 -1 '� 0 A.F.F. •},,,�� .
KITCHEN 10 o MAX. DOWEL+EPDXY
Q I GROUT REINFORCEMENT 30 TO 40 +41, -45 +41, -53 —11 PRJ• MNGR. DRAWING BY ScA�E
EXISTING 00 INTO EXIST. BEAM ABOVE MW CG - " '-0"
MASTER BEDROOM o 0 00 1 I D TYP. 2X4 PARTITION: 4" +FOUNDATION BELOW - - SHEET Tm_E
"' I- - -J SI K STUDS .® _16"O.C. W/ J".
40 TO 50 +40. 44 +40. 52
DRYWALL, BOTH SIDES 02 I DEM
O Q 1 S 50 TO 100 +38, -42 +38, -47
o TYPICAL FULLY GROUTED CELL
V , 4" o W/ 1 #5 CONTINUOUS - DOWLED LO P A
2 - 3'-0" =77/7 + EPDXY-GROUTED INTO EXISTING iii WIDTH OF CORNER ZONE = 3'-6"
- T-5" '-6 3'-4" TIE BEAM + FOUNDATION
12-- ® BATH
Q —12
04 BLOCK IN EXIST. WINDOW 03 0 + W D
OPENING. STUCCO EXTERIOR
- + DRYWALL INTERIOR
HE LES
FLOOR PLAN 6'-10" 13'-5" 6'-10"
- SCALE: 1/4"=1'-0"
27'-0" J NUM S NUMBER
0 01 A-2
A e I I I I I I I I 9 20 2
D E F G H I J K L M N O