00-1068-028 ' REVISIONS BY
) ) ) )
ti
)
)) ) )
MIN 2 FT. VENT CAP
Y
( BUT 2FT.HIGHER THAN
HIGHEST POINT WITHIN 10 FT. )
LL.
N
z
Q0
FLASHING �' N
—00
N
FAINIM Q N
U Lo
DUCT CLAMP ov
BOLTED TO DESK
FIRE RATED CONCRETE
Fmm
OR CONCRETE BLOCK WALL ¢_
3M FIRE BARRIER Q
MOLDABLE PUTTY TRUSSES
INSTALLED FLUSH TO MAXIMUM MAXIMUM MINIMUM PUTTY 'F'
0
BOTH SURFACES OF PIPE SIZES OP'NG SIZES THICKNESS RATING ' Ld
THE WALL
METAL PIPE /CONDUIT
�--AS REQUIRED FOR CLOSURE 5 6 1/4' '/2' 2 HOUR CEILING V)
UL SYSTEM No202
I10' 12 i/a' I' 3 HOUR
1/2' N.W. 4' 0 FLUE ui
PROVIDE CELL CLOSURE NOTE: TO FIX METAL5E6TO5 TYPE B ® C>
OF NON-COMBUSTIVLE MAXIMUM ANNULAR SPACE BETWEEN PIPE AND OPENING 70 ROOF VENT
MATERIAL IN C.M.U.WALLS NOT TO EXCEED 3�a' HEAT TRAP V �Lu VACUUM BREAKER
N
PENETRATION FIRE5TOF FOR METAL }PIPE/ CONDUIT I � _LO--------�-`3�ECIRC.PU P: 5 4 Zn
� � � RECIRC.PUMP B G MODEL
LR 20 BF �1/20 HP - 120 VAC. o z
T�IROUC�>�I � CONCRETE WALL ------- Vy ..
P k T RELIEF VALAEE I 0 DIELECTRIC i/2' RECIRC.LINE IN ATTIC SPACE 1
TO 6' ABOVE ; I UNIONS(TYP.) {
GRADE 1
f
1i2' GAS TO LPG TANK o0
X1/2' RECIRCULATING LINE ¢ .
75 GAL 1, i
2'GAS
GA5-FIRED
1 WTR - HTR
EF : 051
i
3/4' RELIEF 50,000� 87U
GRADE
INPUT
i
S' CONCRETE
GAS COCK VALUE
BLOCK WALL t>
4'4
AMERICAN MO
DEL NOTES:
P. I/2FYRE-5HIELD G5215T514N c a ;4 ,a V'a TREM5TOP MFG. REGIRC
.PUMP SHALL BE TURNED ON BY
i P.
y r"=
?
I WATER HEATER INTERNAL AQUA$TA7 a =°• �
3001 ��� 0(N,A (( '
BELOW 120° F WATER TEMP. IN TANK
FUTURE HEAT REC./SOLAR
HEATER CONNECTIONS f�
j
.g
1' THICK POLYURETHANE
GA5 WATER HEATER DETAIL
` °4 °°BACKER ROD FRICTION 'a.a�o1 V. COPPER PIPE
FITTED INTO OPENING ,
v
a
NOTES: MAXIMUM AREA OF OPENING IS 258 SQ. IN.
COPPER PIPE: 4'� (OR SMALLER)REGULAR( OR HEAVIER)COPPER
MAXIMUM NUMBER OF PIPES WITH OPENING 15 THREE (3)
APPLY 1/2' FYRE-SHIELD TO BOTH SURFACES OF WALL
CONSULT CURRENT UNDERWRITERS LABORATORIES 'FIRE RESISTANCE DIRECTORY' FOR DETAILS
UL 5Y5TEM CAJ IO41
MULTIPLE COPPER FIFE
THROUGH CONCRETE WALL
2 HOUR FIRE RATED
FL_UM5ING NOTE-5
01 - ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE
WITH THE 5F$.C.,A$ME CODE AND AGA REQUIREMENTS AND ALL OTHER
APPLICABLE LOCAL CODES.
02 - ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING SUBCONTRACTOR,
ALL PERMITS FEES FROGRE55 PLUMBING SYSTEM SHALL BE FULLY OPERATIONAL
AND ACCEPTANCE BY THE ENGINEER SHALL BE A CONDITION OF THE CONTRACT.
03 - CONTRACTOR SHALL VERIFY THE LOCATION OF THE EXISTING WASTE AND VENT
LINES.
04 - FURNISH AND INSTALL APPROVED AIR CHAMBERS AT EACH PLUMBING FIXTURE GROUP.
05 - ALL MATERIAL AND FIXTURES FURNISHED SHALL BE AS SPECIFIED ON THE PLANS
OR SPECIFICATIONS.
06 - CONTRACTOR SHALL PROVIDE FOR ALL PERMITS, INSURANCE, INSPECTION$AND TESTS.
01 - DRAWINGS ARE DIAGRAMMATIC.CONTRACTOR SHALL VERIFY THE LOCATIONS SHOWN '
ON THE DRAWINGS WITH THE ARQUITECT PRIOR TO COMMENCING WORK 1
08 - ALL SOIL,WASTE AND VENT PIPING TO BE PVC SCHEDULE 40.
09 - DOMESTIC WATER PIPING:
cn
ABOVE GROUND FLOOR SLAB:
COPPER TYPE K,L OR M WITH SOLDERED JOINTS cm
UNDERGROUND OUTSIDE BUILDING: � ,
C,LEGE ID COPPER TYPE K WITH SOLDERED JOINTS r°I�
CONNECTION FIXTURE 5CHEDULE I�
FIXTURE COLD WATER HOT WATER P.TRAP F.U. BELOW FLOOR SLAB: LL
R RELIEF LINE COPPER TYPE M INSIDE MINIMUM 1/32' THICK PLASTIC
WATER CLOSET 1/2' - 3' 4 CD VENT CONDUITS ITS ENTIRE LENGTH INCLUDING TURN ABOVE SLAB 11_ �a Lu
SANITARY NO PIPES JOINTS BELOW SLAB U Q m
LAVATORY 1/2' 1/2' 11/2' 1 SAN 1Z e
HOT WATER USE 95/5 SOLDER t— �
SINK 1/2' 1/2' 11/2' 2 - - Q V) W A)
COLD WATER LLI � W IC 'L
SHOWER I/2' I/2' 2' 2 10 - DOMESTIC NOT WATER PIPING SHALL BE INSULATED WITH 1/2' ARMAFLEX OR
W.C. WATER CLOSET RUBATEX OR EQUAL.
BIDET I/2' I/2' 2' 2
SK $INK I�
SPECIAL PROVISIONS Il - SLOPE ALL WASTE LINES A$NOTED ON SPECIAL NOTES Lu
111
BATH TUB I/2' I/2' 2; 2 LAY LAVATORY z
WA5HER 1/2' 1/2' 2 4 1.HORIZONTAL WASTE LINES 5H SHOWER 12 - WATER VALVES FOR COPPER TUBING LINES SHALL BE BRONZE ZE BODY WITH -q W �
2'� AND BELOW 9 'ia' /FT.SLOPE BD BIDET PRESSURE RATING OF 115 LBS,NON SHOCK COLD WATER AS MANUFACTURED
DISHWASHER - 1/2' 11/2' 1 3'm AND ABOVE .9 ��s' /FT.SLOPE BY NIBCO OR APPROVED EQUAL. Ck
REFRIGERATOR 1/2' - 2.UNDER FLOOR SLAB WASTE IVES BT BATH TUB • z
ER L L W WASHER 13 - FURNISH PIPE HANGERS AS REQUIRED BY THE 5F$.C. O U O
LAUNDRY TRAY 1/2' 1/2' 2' 2 2'�MINIMUM SIZE 9 Zia' /FT.SLOPE DW DISHWASHER GRINNED OR EQUAL jL OO ,fin. LL
HOSE BIBS 1/2' - - - 34 AND ABOVE m HIV /FT.SLOPE
MAINTAIN UNIFORM SLOPE ON BLDG.DRAIN C.O. CLEAN OUT 14 -
REF REFRIGERATOR PIPING TESTS.
JACUZZI I/2' I/2' 2' 2 TEST ALL WASTE LINES WITH A MINIMUM OF 10 FT,OF HEAD OF WATER WITH WATER LEVEL ..
3.BATHTUB AND SHOWER 55 BAR SINK
PROVIDE ANTI-SCALD VALVES H$. HOSE BIB$ AND UPPER'10ST POINT OF SYSTEM
1. FURNISH ANTI-SCALD VALVES FOR BATHTUB$ AND SHOWERS 4.HOSE BIBBS: JZ JACUZZI TEST ALL WATER LINES WITH A MINIMUM OF 100 PSIG HYDROSTATIC
2. FURNISH VACUUM BREAKER FOR HOSE BIBBS RESSURE FOR A MINIMUM SUSTAINED PERIOD OF 8 HOURS
ALL H.B.H WITH VACUUM BREAKER VALVES VTR VENT TO ROOF
ti.
5.O V. SHUT OFF VALVE 15 - FURNISH CLEAN-OUTS AS PER SECTION 46082 OF THE Sr—BC,
DRA .,
CHECKED
E.A.C.
DATE %k,
APRIL '00
_ SCALE
SHOWN
JOB No.
2K-216
SHEET
dy
rs _
�•