Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
00-0967-001
r A/C a' ROOM s 0 21 I I I O 20 15 I � j� 15 ` P O O O 50 17 18 19 I 22G) TELE. P.B.X. EQUIP. i I vu L�DJ �,�. ter., tom, fit•, IC7�!, la-, IC71!, �_� .,.._.� is 1s 77 7D to is � cv�.t,.ni�c 9 10 11 12 13 14 15 .875A an \Jt' 15 15 15 15 15 15 15 15 EOLCKT#2 � ^ 1 2 3 4 5 6 7 8 1'A J m�� �� INE FL ® ® R LAN 49 L�JP VAULT VP SCALE: 1/8" = 1'-0" 19 20 2 2 Ea 1 2 I 2 2 2 2 2 2 2 2 2 2 2 Ea 41 42 43 44 45 46 47 48 49 50 51 2 2 2 2 2 I 2 2 EOL 27 28 29 30 31 32 33 34 35 36 37 38 39 40 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 EOL 14 15 16 17 18 19 20 21 22 23 24 25 26 52 53 54 15 2 2 2 2 2 2 2 2 2 2 2 2 2 EOL 8 MARKETING VACANT PURCHAS'G 1 2 3 4 5 6 7 8 9 10 11 12 13 DIRECTOR 4C/18AWG 15 7 48 VAULT C/D BOARD �� H H H H H H H H H H EOL v' i STORAGE COMPUTER 2 @P TRUST ^ ROOM ROOM 12 13 14 15 16 17 18 19 20 21 VP 22 23 18 @P H H H H H H H H H H H H EOL f 43 �, n_ 21 6 1 2 3 4 5 6 7 8 9 10 11 '« `4:5/Y �46JF' 47 0 0 0 o Ea NOT AN 1 2 3 4 EXIT 2C/18AWG FPLP COMPUTER V P TRUST OFFICER t t O O O 54 UNIMODE 4520 PH41 F VAULT , 3 54 ADT FACP FOCUS 200 PH42 AUDITOR ^ 16 ATM DIALER . 15 UP •:' 14 2Up EOL 17 (EXISTING) ADT 26 1 , (EXISTING) 4520-810 P.S.U.F�== O c TRUST 6 15 52 4 43 0 0 O v 25 25 O P CAFETERIA 27 20AMP CKT BREAKER 24 z V.P. 5 15 120V DEDICATED 20AMP CKT BREAKER o DEDICATED DESK COLLECTION 15 9 28 O2 p 2 - COUNTER ' �P v' 15 RISER DIAGRAM X122 13 11 V.P. � MEN WOMEN MAIL W 3 p 0 (�1, N.T.S. ROOM z O 2s 5t OP9 1 2 � q 11 33 `P S E � ONID F L� ® � t� P LAIN 4 ,4 NOTES ' SCALE: 1/8" = 1'-0" � BOOKEEPING 3 n A.V.P. 1. THESE UNITS OR DEVICES SHALL BE INSTALLED USING APPROVED MATERIALS AND VP 2& WIRING PRACTICES IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE x/70 32 30 OH AND THE NATIONAL FIRE PROTECTION ASSOCIATION ARTICLE #760 POWER LIMITED MEN WOMEN SECTION AND ALL APPLICABLE LOCAL WIRING ORDINANCES. TELLERS 2. CONDUCTORS AND CABLES FOR USE WTH THIS POWER LIMITED FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE TO THE NATIONAL FIRE PROTECTION =VAULT ❑ ASSOCIATION ARTICLE #760 POWER LIMITED SECTION AND SHALL BE LISTED FOR 15 12 to THIS USE. CONDUCTORS SHALL HAVE A MINIMUM RATING OF 300 VOLTS AND SHALL O2 p 15 BE OF SOLID COPPER OR BUNCH-TINNED STRANDED COPPER CONDUCTORS_ OE 0 0 35 15 1 1 � V 3. CONDUCTOR USED IN DUCTS OR PLENUH CEILINGS FOR ENVIRONMENTAL AIR SHALL @P EMPLOY THE USE OF ELECTRICAL METALLIC TUBING OR TEFLOiv INSULATED TYPE CONE FILES ( z 9 e CABLE WHICH MEETS THE REQUIREMENTS OR THE NATIONAL FIRE PROTECTION MEN �H ®p EOL o ASSOCIATION AND ARE U.L. LISTED OR COMPATIBLE FOR THIS USE. 40 Y O G) GENERATOR u v 12 W o 4. FPLP OR FPLR SIGNAL CIRCUIT CABLE FOR USE IN ACCORDANCE \:9TH NEC ART 760 15 14 0 34 Q VAULT SHAFER 10 it AND NEC ART 725 CLASS 2 OR 3 CIRCUIT.10 13 I WOMEN AC @P CUSTOMER W 5. THIS IS A POKIER LIMITED FIRE SYSTEM. 36 37 W SERVICE SIGNATURE CONTROL r �,x,;�,;�z, �;-: 1 6. ONLY SMOKE DETECTORS #52, 53, & 54 ARE BEING ADDED TO AN EXISTING SYSTEM. O E ALL OTHER DEVICES ARE EXISTING. i v 2 H PRESIDENT "s s t'. % .�'?1 �. `` i 39 V.P. DESK DESK 7 •, _ .✓_ _ <-57ir 4 FTn.E ELI.. R, r cn i H STUNIG INST 1-- T'�Iv1 T E 1t ACCOUNTING : •-. •• _ ��z'J , DIR. HUMAN XJ O B a 15 Y 011iPLY VV; 0�: �I�tLCJ�JG CCQRD,,V 1C i?Vtll H I. RESOURCES O u' 4ZrAT � 6`, . �..'' _ _. H 0 _ CCUPA � ` G4/'�: ""IS CF SHALL NI Pay 72;70; 101-7,G w .- � � �?Y n�:11 <: ExJSrJJV� Op DATE C'ET FORTH I 16 .�._. PA 101 LIFE �.AFETY CODE N 1-I C114- COUNTER �, @P SEC. o CLERK o CLERK o coG s V.P. 15 15 5 13 2 Ri=CEP. 3 FIRE ALARM LEGEND � 15 LJP Op N CONTRACTOR SHALL COORDINATE ALL MOUNTING HEIGHTS AND FINAL LOCATIONS 42 41 A.V.P. o OF DEVICES MATH A REPRESENTATIVE (PRIOR TO ROUGH-IN). 2 DESK DESK DESK DESK SYMBOL DESCRIPTION PART �/ CATALOG �/ MANUFACTURER _s L L FIRE ALARM CABINET-INSTALLED 5'-0" AFF UNIMODE 4520 ADT POWER SUPPLY 4520-810 P.S.U. ADT SR.V.P. V.P. A.V.P. COMPUTER ,« COLLECTOR APPL'N � 3 CHAIRMAN ^ SR.V.P, ae FIRE ALARM MANUAL PULL STATION ADT-BG-10 ADT UP CASHIER ,,. O2 p @ 3 4 E 15 FIRE ALARM HORN-STROBE-"RED" CANDELLA GX90S-4-15/75-W GENTEX i 2 V.P. A.V.P. V.P. o OD DUCT SMOKE DETECTOR P.O.C. BY OTHERS v O OP PHOTO ELECTRIC SMOKE DETECTOR 3534-2 CRT ADT ' Q HEAT DETECTOR 4220-135 ADT HO Y m I J Q 0 FERST FLR LrP z ® ® LAN z _ ~ SCALE: 1/8" = V-O" U- i z 0 a U SECURITY SERVICES, IMC. Ld REVISIONS © ® 7747 N.W. 48th STREET, STE. 160, MIAMI, FLORIDA 33166 o DESIGN NO.: DATES: BY: TONY CHIN EF# 0000911 `� (305) 639-3007 FAX (305) 629-2906 � IJ J J��I � FIRST NATIONAL BANK U 8/22/00 H.T. `� 2 OF SOUTH FLORIDA 3 5750 SUNSET DRIVE HAROLD TUSSLER MECHANICAL ENGINEER ##FL19315 4 S. MIAMI, FL. 33143 DESIGNED BY: DWG 8Y: � 1710 AVENIDA DEL SOL BOCA RATON (561) 392-4336 5 H.T. FIRE ALARM PLAN A.Z. BOCA RATON, FL 33432 BROWARD (954) 975-6829 6 DATE: SCALE: SHEET NO.: DWG, NO 7 8/11/00 1/8 1'-0" 1 OF 1 00154 i