00-0883-053
, > 1 1 ) J 1 ) ) 1 3 EXISTING OUTSIDE AIR INTAKE @ 1370 CFM. cn )) > > ) REBALANCE TO 1670. SCOPE OF WORK u u wcf) UNASSIGNED "5 O O ' CHWS/R O , ,,' > > Z Lu L{) � '0 —r '�`� � � WASH O uj LA UNASSIGNED I .L` UNASSIGNED �+ APU En 2 - x10 - 26x10 ; r r C p" 2' p' " „ m M an J.C. I 1 48x10 UNASSIGNED 1 I L I L1 1 - — -- � Lu 0) VEST. �— _I q �C I LO T- -- - 10 6 ,_1 t t U ¢ O `\1 I Qs I \�, I CORR. N I I k�J r -- -�-� i ► 6X6 VD - � a LL ct°o �, �, 12�C 2 1O TEST AND BALANCE EXISTING FAN TO 750 CFM. PRE-TEST FAN WITHIN ONE WEEK z = UNASSIGNED I CORR.1 _.. CORR. 4X6 e e 1 I 1 ��'�)'), FROM AWARD OF CONTRACT AND SUBMIT RESULTS FOR REVIEW. Q o Q ,� n ( 1 N UNASSIGNED 2 6 M o I D 8 8 UP THRU ROOF ABOVE. TERMINATE WITH GOOSENECK. TERMINATION M. WASH ROOM S �Y ?, 11 VEAU- 4 x VEST. I I 1 DISCHARGE IS GREATER THAN 10'-0" FROM INLETS AND OPERABLE WINDOWS, BOTH o 48x1 1 1 VERTICALLY AND HORIZONTALLY. © LOUNGE S" r �,- �I UNAAHU-B -1 RE�"1�CN x N 1/2 WS/R- -i A40 OBT IN I 1 2 Lyl MECH. 1XII SEE LIFE 1 O I 1 ? `. ,% A23 8X6 Q3 PROVIDE NEW FAN COIL UNIT. INSTALL FAN COIL UNIT AS HIGH AS POSSIBLE . O . AIR QU ; ; I ABOVE THE CEILING. NOTE THAT EXISTING ORIGINAL PLASTER CEILING IS TO BE W VEST. r 1 . HOLDING LDING P ANTFOR i X 1 `. REMOVED. REFER TO ARCHITECTURAL PLANS. THE INTENT IS TO LOCATE THE FAN a L. W SH ROOM vEST. 8x10 -j �"f RI. 0 ' CONT. P 1 COIL UNIT AS HIGH AS POSSIBLE WITHOUT HAVING TO RELOCATE THE EXISTING, TL I " i ' I 1 REMAINING UNIT SHUT-OFF VALVES AND TO NOT CREATE A DROPPED SOFFIT TO CONVICT COMPARTMENT _ ____ T 2 CHWS/R - 1 =_ _ A400 TU 2 ' HOUSE THE UNIT. DO NOT RISE THE S/A DUCT IF THE UNIT CAN BE INSTALLED ® ice' -r ---- 1 COMPLETELY ABOVE PROPOSED NEW CEILING HEIGHT. THE FAN COIL UNIT ci 15x14 © ? 'A SCHEDULE IS A FOLLOWS: l 21 x14 PRISONERS LWA,fD 23x14 1 130 �, _I_ VD _ _ a W w , 112>2 © 18x14 I _ N 1 STAFF STATIO N 155 T i -Y`- A 2 * MANUFACTURER/MODEL NO. - CARRIER 42CF04. a SECURITY CHAMBER STOR. LT. OFFICE - _ ;< PI. O I I �I 12X6 LL a � STATION i 1 8 * SUPPLY AIR/ESP - 250 CFM/.30 IN.W.C. W .. �� EL xv-1cY(E)l3(P r PRI. — T * COOLING COIL - 3 ROW, 1.4 GPM, 5.OAP, 44'/54'. uj 1 * COOL CAPACITY 7000 Q TOTAL/5700 Q SENSIBLE. W k/n T. UT. CLEAN � T S I I 12X E/T 2 * ENT AIR/LVG AIR - 75,63/56.6,54.6. of T R. ( T. * — z a W STAFF S O I HEATING COIL 1 ROW, 10,000 BTU (CAPPED FOR FUTURE CONNECTION). o W I RECREATIONAL AREA � 745 � —p o CORR. ( Tv I o F -4 10X - * ELECTRICAL - 1/8 HP @ 120 V/1/60. o c 8 TELEMED. HEADR T 1 N TV T• NURSE I 1 —� PROVIDE WITH COMPANION THERMOSTAT AND FILTER GRILLE WITH 30% ASHRAE ELEC. ® a OFFICE I t�);, 1 4 EFFICIENCY FILTER.jvz �� 0 cLO. I (E)l B 1 I APU 2 8X6 Lu N SECURITY PASSAGE WAY (N 1 I I " o I- PRIS. RECV. RM I ( j Hi PRI. ROOM Tv I I ® RECONNECT EXISTING 1/2 CHWS/R TO NEW FAN COIL UNIT. PROVIDE THE TV C 0 O X I FOLLOWING VALVING/APPURTENANCES w w v, 0 ON ELEC. RM. N N 'PRI. ROOM TV �g _ PRI. ROOM i PRIS. ISO. RM- J C o T I * RETURN PIPING * UNION. y w a o * COMBINATION TEMPERATURE/PRESSURE GAUGE PORT. �, w * BALANCING VALVE WITH CALIBRATED READ OUT PORTS. STAIR 7 T. T * THREE-WAY CONTROL VALVE. ��+, v' * SUPPLY PIPING * UNION. � Z � N * COMBINATION TEMPERATURE/PRESSURE GAUGE PORT. w © ISOLATION ROOM 7TH FLOOR PLAN * STRAINER. � AI BUILDING SEVENTH FLOOR PARTOAL LO FE PL� SCALE 1/4 -1 _0111 0 Q PROVIDE THIS DIFFUSER WITH A 12 x 12 FACE. ORIENT THE OPEN END SUCH THAT IT TERMINATES AT A NORTH TO NORTHEAST DIRECTION FROM ROOF CURB. 1/4"x 1/4" u u MESH ALUMINUM O BIRDSCREEN GOOSENECK. CONSTRUCT OF 0 ' CHWS/R o 22 GAUGE ALUMINUM. MATCH I' ;' THE SIZE OF THE CONNECTING DUCTWORK BELOW BUT IN NO i ----- - �° ____ _-_� — 6" MINIMUM CASE LESS THAN 12 x12 . _ k�J I z r I � I �� I J, � '� � ( O I Ile 11 11 V� SECURE BACKDRAFT DAMPER THROUGH —� -'I -__ _ �' w I E, T r� DUCT FLANGE TO DAMPER TRAY 45 SLOPE FROM CURB ANGLE SUPPORT WITH SHEET I I 744 � METAL SCREWS. SET IN DUCT SEAT TO GOOSENECK SIZE. 1 I KEYED DEMOLITION PLAN NOTES SEALANT. PROVIDE 8 INCHES ON I I 1 1 CENTER BUT NOT LESS THAN WEATHERPROOF GASKETING TWO (2) PER SIDE. ALL AROUND. 1 /2" WS/R 18" MINIMUM Q ACCESSORY ROOF CURB WITH GOOSENECK CURB FLASHING DAMPER TRAY ANGLE SUPPORT. 1 11 x I ' _� ® nl REMOVE EXISTING WINDOW MOUNTED FAN AND RELATED POWER, CONTROLS AND I x I SUPPORTS. �- !h 3/8 INCH DIAMETER, 2 INCH LONG, P S I � w ® �; STAINLESS STEEL SCREWS SET IN 2" CHWS R = 1 __ - �" w g WEATHERPROOF MASTIC. PROVIDE REFER TO ARCHITECTURAL PLANS / ;- - TV ® REMOVE EXISTING EXHAUST AIR GRILLE AND CONNECTING DUCTWORK TO I 8 INCHES ON CENTER, BUT NOT ��� FOR ROOF CURB-TO-ROOF ' �� BEYOND THE CORRIDOR WALL PENETRATION. CAP OPEN END OF BRANCH C LESS THAN TWO (2) PER SIDE. SECURING AND FLASHING DETAILS. 1 I _ i © DUCTWORK. BACKDRAFT DAMPER TRAY SUPPORT \ ' ' - � -- _ ROOF. REFER ARCHITECTURAL I �� I 20X8 f1 Q REMOVE EXISTING FAN COIL UNIT INCLUDING BUT NOT LIMITED TO CONNECTED ^ 's PLANS FOR CONSTRUCTION I -------- � SUPPORTS, SUPPLY AIR DUCTWORK AND CONNECTED AIR DISTRIBUTION, RETURN AND SLOPE. r-- I 1 I I AIR DUCTWORK AND CONNECTED GRILLE INCLUDING DUCT AND GRILLE v) GALVANIZED SHEET METAL SDI CONNECTING TO CORRIDOR BEYOND, POWER AND CONTROLS. o DUCTWORK. SEE PLAN FOR I I E T � BACKDRAFT DAMPER SIZES. ROUTE UP THRU ROOF I 1 0 T. 745 ® REMOVE EXISTING SUPPLY AND RETURN CHILLED WATER PIPING FROM THE FAN AND TURN ENDS TO FORM 1 0 COIL UNIT BACK TO (BUT NOT INCLUDING) THE SHUT-OFF VALVES. THIS REMOVAL z w cn FLANGE. SET FLANGE END ON 1 o I INCLUDES BUT IS NOT LIMITED TO CONTROL VALVES, FITTINGS, SUPPORTS, o C- I- ROOF CURB DAMPER TRAY I N ___ _ o z SUPPORT. -- _--� STRAINERS AND BALANCING DEVICES. � N � moo B Z I j Woa 0 U DETAIL: TYPICAL GOOSENECK (GN) N.T.S. 1 w T I I i I � � .LLJ 0 co 0 1- N Zoo Q .— o w o � ,�; o , ROOD AIR BALANCE ROOM DESIGNATION ROOM 744 N ISOLATION ROOM 7TH FLOOR DEMO PLAN TOTAL ROOM SUPPLY AIR (+) (CFM) (+)235 -``' ,;,r � •���� h SCALE 1/4 =1 _Ojj te h s •. F TOTAL ROOM RETURN AIR (-) (CFM) (-)160 TOTAL ROOM EXHAUST AIR (-) (CFM) (-)150 c ' 1,ialllt4s NET ROOM AIR BALANCE (+ OR -) (CFM) (-)75 DESIGN NET ADJACENT SPACE AIR QUANTITY CHANGE (+ OR -) (CFM) (+)75 DRAWN O A. kI,L.F. COMPLIANCE WITH CHAPTER 59A (YES OR NO) YES CHECKED NOTES 1., 2. O.A. SCALE AS SHOWN DATE 1 . EXISTING SUPPLY AIR DIFFUSERS EACH INCREASED BY 25CFM. 08-04-98 PROJ. No. 2. THIS CALCULATION ALSO TYPICAL FOR ROOM 745. 200017 SHEET No. oA HVAC. MAIN BUILDING SEVENTH FLOOR PLANS