00-0883-048
AIR PURIFICATION UNIT SCHEDULE - APU AIR DISTRIBUTION LEGEND - TYPE A GENERAL N®T ) ; ) a DESIGNATION A B C D E 0 F � OP�r.R BLS CONTROLS MEASURE FIVE z w U) 2 ® A 100 ---- SUPPLY AIR QUANTITY, CFM 1 . MOUNT CONTROL PANED )THA�11; ' T" w ~ BUILDING PAVILION PAVILION NORTH TOWER EAST TOWER MAIN MAIN FEET, SIX INCHES (5 -6 )) )A8O�1E ) FINrSN�R ;F)L�OR. � ? c 2 AIR DISTRIBUTION TYPE, PERFORATED 1ST FLR. 2ND FLR. 2ND FLR. 6TH FLR. 7TH FLR. 7TH FLR. FACE DIFFUSER, 24"x24" CEILING MODULE SIZE. 2. NO FLEXIBLE DUCTWORK IS ALLOWED. �' m CO M . AREA SERVED CO ,� a o EMERGENCY RECOVERY RM. MICU ENDOSCOPY D.O.C. D.O.C. cn uj o RM. 3 RM. 744 RM. 745 3. PROVIDE ALL WORK AS SPECIFIED HEREIN AND IN COMPLIANCE WITH Q o w THROW PATTERN THE FOLLOWING CODES: r ACCESSORIES-CONTROLS A A A A A A c0 * SOUTH FLORIDA BUILDING CODE, 1994 DADE COUNTY EDITION a �- �° J NOTES 1 ,2,3 1 ,2,3 1 ,2,3 1 ,2,3 1 ,2,3 1 ,2,3 ® INCLUDING THROUGH SUPPLEMENT NO.4 z cq Q HEPA FILTER - 99.9995% EFF. @ .12 MI. YES YES YES YES YES YES * NFPA 99-1993, STANDARD FOR HEALTH CARE FACILITIES. a co a O �zIfy- 4-WAY 3-WAY 2-WAY 1 -WAY NFPA 90A-1993, STANDARD FOR THE INSTALLATION OF ^ M UVGL - 30 WATTS YES YES YES YES YES YES * AIRCONDITIONING AND VENTILATING SYSTEMS. STYLE 0 WALL MOUNTED WALL MOUNTED WALL MOUNTED WALL MOUNTED WALL MOUNTED WALL MOUNTED SUPPLY AIR DIFFUSER CONNECTING BRANCH TOP DISCHARGE TOP DISCHARGE TOP DISCHARGE TOP DISCHARGE TOP DISCHARGE TOP DISCHARGE NECK SIZE DUCT SIZE IN.xIN. CHAPTER 59A-3, REVISED 7/1997, HOSPITAL LICENSURE. RANGE, CFM IN. ROUND RECTANGULAR * FLORIDA ADMINISTRATIVE CODE 4A-3 - APRIL 1995, FIRE 3 MEDAIR 3 MEDAIR 3 MEDAIR 3 MEDAIR 3 MEDAIR 3 MEDAIR DESIGN BASIS MANUFACTURER PRODUCTS GROUP PRODUCTS GROUP PRODUCTS GROUP PRODUCTS GROUP PRODUCTS GROUP PRODUCTS GROUP 0-120 6" 6"x8" MARSHAL RULES. W Z 121 -210 8" 6"x10" 4. ALL DIFFUSERS ARE 4 WAY THROW UNLESS NOTED OTHERWISE. 0. DESIGN BASIS MODEL NUMBER A SCU-30N-4T 20 SCU-30N-4T SCU-30N-4T SCU-30N-4T SCU-DOC-20N SCU-DOC-20N 0 ELECTICAL DATA - V/PH/HZ 120/1/60 120/l/60 120/l /60 120/l /60 120/l/60 120/l /60 211 -300 10 8„x 14 x 12" 5. FIELD VERIFY EVERY ASPECT OF THIS JOB BEFORE BIDDING THE WORK. ,� , ELECTICAL POWER - FLA 3.9 3.9 3.9 3.9 3.9 3.9 301 -390 12 8„ 6. OWNER HAS FIRST CHOICE OF REFUSAL ON ALL WORK NOTED o z SUPPLY AIR (CFM) A 300 0 350 0 515 A 400 400 400 391 -530 14�� 8 x16 FOR REMOVAL. PACKAGE ALL ACCEPTED WORK, LOAD, TRANSPORT, W 531 -600 16 8„ Q x18 1) DOWNLOAD AND STORE IN OWNER APPROVED LOCATION. OWNER W EXTERNAL STATIC PRESSURE (IN. W.C.) .25 .25 .20 .25 .25 .25 a w > N DISCHARGE DUCT COLLAR SIZE (2)-4"x10" (2)-4"x10" (2)-4"x10" (2)-4"x10" (2)-4"x10" (2)-4"x10" AND CONTRACTOR SHALL EXAMINE THE ACCEPTED WORK BEFORE a co PACKAGING. IF, AFTER TRANSPORTATION AND UNPACKAGING, DAMAGE 2 � o w IS DISCOVERED TO THE WORK CAUSED BY THE REMOVAL AND/OR ui -" o_ MAXIMUM DISCHARGE SOUND RATING AT NOTES MAX. S/A FLOW, ( HIGH SPEED) dbA 50 55 55 55 55 55 TRANSPORTATION PROCESS, CONTRACTOR SHALL REPAIR THE UJ DAMAGE TO THE AS EXISTING CONDITION OF THE WORK OR PAY z = z ACCESSORIES 3 NOTES: W THE OWNER THE PRESENT FAIR MARKET VALUE OF THE WORK. 3 J 0 O co A. TSI PRESSURA ELECTRONIC PRESSURE MONITOR 1 . THE EXTERNAL STATIC PRESSURE LISTED ABOVE IS THAT 1 . DIFFUSER SELECTION IS MADE BY OBTAINING THE CFM FROM AN "A" 7. ALL WORK REFUSED BY THE OWNER BECOMES PROPERTY OF INING: ENCOUNTERED BEYOND THE UNIT AND IS EXCLUSIVE OF CONTRACTOR. DISPOSE THIS WORK OFF SITE. o DESIGNATED DIFFUSER FROM PLAN AND SELECTING AN APPROPRIATE 1 . TWO-SPEED BLOWER SWITCH HEPA FILTER AND OTHER UNIT INTERNALS THAT MAY NECK SIZE ABOVE BY MATCHING THE PLAN CFM TO THE APPROPRIATE CONTRIBUTE TO PRESSURE LOSS. A CFM RANGE. 8. THE WORK TO BE DONE UNDER THIS CONTRACT IS AIR DISTRIBUTION co 2. DIGITAL ROOM PRESSURE READ-OUT AND AIR FILTRATION ONLY. NO NEW A/C ENERGY HAS BEEN USED. ,._. CD 3. STATUS INDICATOR LIGHTS 2. T R T POWER, 4. AUDIBLE ALARM 3 BUT UNIT IS NOT SHIPPED WITH ACTUAL BULB. 2. DIFFUSER SELECTION INDICATED ABOVE WERE BASED ON A MAXIMUM c 9. ALL NEW DUCTWORK SHALL BE GALVANIZED SHEET METAL, CONSTRUCTED � "' 5. WALL MOUNTING PLATE AND HARDWARE 3. UNIT SHALL OPERATE CONTINUOUSLY UPON FIRE ALARM NOISE CRITERIA NOT TO EXCEED "NC30" WHEN SELECTION IS MADE AT IN ACCORDANCE WITH SMACNA AND ASHRAE. ~ 6. T NTE ACTIVATION. 0 THE UPPER PART OF THE SUPPLY AIR RANGE. w a Lu 7. PREMIUM UNIT FEATURES INCLUDING 3 10. INSULATE COOLING SUPPLY AIR DUCTWORK WITH 1 -1/2", 3/4 PCF , PRESSURE MONITORING OF (2) ROOMS, 3. PROVIDE CONNECTING BRANCH DUCT SIZES NOTED ABOVE UNLESS DENSITY FIBERGLASS INSULATION WITH FOIL SCRIM KRAFT VAPOR BARRIER w w y� C VOLUME FROM CALCULATIONS, AIR NOTED OTHERWISE ON PLANS. COVER. MAKE ALL JOINTS AND SEAMS WITH GLASS-FABRIC AND MASTIC. `� �' EQ 0.. EXCHANGE RATE CALCULATIONS, AND DO NOT INSULATE EXHAUST, OR AIR PURIFICATION UNIT RECIRCULATING m ACCEPT INPUT FROM ROOM DEDICATED 4. PROVIDE RECTANGULAR BRANCH CONNECTING DUCTWORK AS INDICATED AIR DUCTWORK. INSULATION, MASTICS AND RELATED MATERIALS SHALL Wwb oc W FEAU (IF INDICATED). ABOVE UNLESS NOTED OTHERWISE ON PLANS. HAVE A FLAME SPREAD OF 25 OR LESS AND A SMOKE DEVELOPED o � RATING OF 50 OR LESS AS TESTED BY ASTM E-84 AND SHALL COMPLY o 5. PROVIDE CONNECTING BRANCH RECTANGULAR DUCTWORK WITH BALANCING WITH NFPA 90-A. DAMPER AT BRANCH DUCT TO MAIN DUCT CONNECTION. PROVIDE ADDITIONAL' ' BALANCING DAMPER- AT NECK OF DIFFUSER 11 . TEST -AND BALANCE-ALL WORK PER THE REQUIREMENTS OF NEBB OR 0 ONLY IF: AABC STANDARDS. SUBMIT THREE (3) COPIES, MINIMUM, OF COMPLETED TEST AND BALANCE REPORT FOR APPROVAL FOR ALL EXISTING AIR A. CONNECTING BRANCH BALANCING DAMPER SERVING RESPECTIVE DISTRIBUTION INDICATED TO BE BALANCED TO A HIGHER (LOWER) AIR DIFFUSER IS LOCATED MORE THAN 12'-0" ABOVE -FINISHED FLOOR, QUANTITY, THE WORK ALSO INCLUDES ADJUSTING EXISTING DUCTWORK WHETHER CEILING BELOW IS ACCESSIBLE OR NOT. MANUAL AIR BALANCING DAMPERS AND/OR EXISTING EQUIPMENT CAPACITIES TO ACHIEVE THE NEW AIR QUANTITIES SHOWN. THE TEST AND B. CONNECTING BRANCH BALANCING DAMPER SERVING RESPECTIVE BALANCE WORK SHALL ALSO INCLUDE: DIFFUSER IS LOCATED ABOVE AN INACCESSIBLE CEILING. A. WITHIN ONE (1 ) WEEK FROM AWARD OF CONTRACT, PRE-TEST ALL EXISTING AIR DISTRIBUTION (E) TO BE AFFECTED BY THE DESIGN INDICATED HEREIN AND SUBMIT FOR REVIEW. CONDUCT TESTING BEFORE ANY WORK TAKES PLACE. B. PROVIDE COMPLETE ROOM PRESSURIZATION TESTING AND - CERTIFICATION AFTER 'COMPLETION OF---THE ,WORK. INCLUDE DIFFERENTIAL PRESSURES BETWEEN ISOLATION ROOMS AND ADJOINING SPACES, AIR PURIFICATION UNIT AIR FLOWS, PROPER A FEAU OPERATION AND AIR PARTICULATE TESTING. ALSO INCLUDE SYSTEM ALARM TESTING. M � 12. SUBMIT SHOP DRAWINGS FOR EACH SYSTEM INCLUDING OPERATION -a Cc FILTERED EXHAUST AIR UNIT SCHEDULE A 2 AND MAINTENANCE MANUALS FOR EACH SYSTEM TYPE. PROVIDE MINIMUM � o 8 HOUR OWNER INSTRUCTIONAL PERIOD. DESIGNATION FEAU-1 FEAU-2 FEAU-3 FEAU-4 BATHROOM BATHROOM BATHROOM BATHROOM 13. INSTALL ALL AIR PURIFICATION UNITS AND FILTERED EXHAUST AIR LOCATION UNITS AND THEIR ACCESSORIES, AS FURNISHED BY THE OWNER. ' CEILING CEILING CEILING CEILING w EAST TOWER PAVILION MAIN BLDG. MAIN BLDG. 14. PROVIDE ALL NECESSARY PERSONNEL, COPIES OF REPORTS, AS-BUILT � G 3-ENDOSCOPY 1-EMERGENCY 7-D.O.C. 7-D.O.C. DRAWINGS, AS NECESSARY DURING AND UNTILL A SUCCESSFUL AHCA CD 0 AREA SERVED FINAL INSPECTION HAS BEEN CONDUCTED AND ACHIEVED. N PRIVATE BATHROOM BATHROOM ROOM 744 BATH ROOM 745 BATH ® -a E M R ACCESSORIES a.b e.f 30 a.b.c.d� 3 a.b e.f a.b e.f 0 • A NOTES 1. 3 1. 1. 3 1. 3 L 3 MEDAIR 3 MEDAIR 3 MEDAIR 3 MEDAIR LEGEND 0 DESIGN BASIS MANUFACTURER ° PRODUCTS GROUP RODUCTS 2!OPRODUCTS GROUP RODUCTS GROUP � c DESIGN BASIS MODEL NUMBER CM-ION CM-ION CM-ION CM-ION z cn cn AIR QUANTITY (CFM) 75 75 � 75 75 o w w E EXTERNAL STATIC PRESSURE (IN W.C.) .25 .25 .25 .25 o ~ o R MAXIMUM SOUND LEVEL SONES N A N A N A N A U Q LL_ Q F ( ) / / / / NEW WORK w v v 0 FILTER TYPE (,� (,o �o to - - EXISTING WORK TO REMAIN R M DRIVE DIRECT DIRECT DIRECT DIRECT �uu ,nv►E- REMOVE EXISTING FLEXIBLE DUCTWORK. > ui A DRIVE MOTOR POWER (AMPS) 2.0 2.0 2.0 2.0 P/A PRIMARY FAN COIL UNIT SUPPLY AIR � o o S/A SUPPLY AIR w rn o 0 C ELECTRICAL (V/PH/HZ) 115/l/60 1 15/1/60 115/l /60 1 15/1/60 0 0 " z E E/A EXHAUST AIR Q o 0 A CONTROL INTERLOCK POINT OF CONNECTION BETWEEN NEW AND EXISTING WORK ACCESSORIES CONTROL INTERLOCK (DAPU AIR PURIFICATION UNIT NO. A =ti ✓,,-4 «• a. DISCONNECT SWITCH d. STATUS LIGHTS I. INTERLOCK WITH ROOM DUCT BRANCH TAKE-OFF AIR PURIFICATION UNIT WITH MANUAL VOLUME DAMPER b. DISCHARGE BALANCING e. GOOSENECK 3 DAMPER MANAGEMENT SYSTEM Q ;,;, '•., � _,. f 4 3 f. ROOM PRESSURE w HVAC LIFE SAFETY SCHEDULE C. HOODED WALL CAP MONITORING � EXISTING ACCESS PANEL HVAC DESIGN REQUIRES: YES NO NOTES WITH BIRDSCREEN © NEW ELECTRONIC MONITOR PANEL FOR DESIGN D.A. AND BACKDRAFT AIR PURIFICATION UNIT. DRAWN DUCT SMOKE DETECTOR X DAMPER F/D FIRE DAMPER A , CHECKED O.A. X ""' F/S FIRE/SMOKE DAMPER AS SHOWN FIRE DAMPER(S) NOTES SCALE SMOKE DAMPER(S) X 1 . THE EXTERNAL STATIC PRESSURE LISTED SD DUCT MOUNTED SMOKE DETECTOR DATE 08-04-98 COMBINATION FIRE/SMOKE DAMPER(S) X ABOVE IS THAT ENCOUNTERED BEYOND THE FILTER TYPE (E) 100 EXISTING AIR DISTRIBUTION PROVIDING PROJ. o. FIRE RATED ENCLOSURE X UNIT AND IS EXCLUSIVE OF HEPA FILTER RA EXISTING (E) 100 CFM AIR QUANTITY. FIRE RATED ROOF/FLOOR X AND OTHER UNIT INTERNALS THAT MAY (,a HEPA-99.995% (N) 150 CFM AIRDQUBALANCE TO NEW (N) 150 SHEET No. X CONTRIBUTE TO PRESSURE LOSS. AT .12M. A CEILING ASSEMBLY FIRE STOPPING X SMOKE CONTROL X . HVAC, LEGEND, NOTES AND SCHEDULES A A A