00-0883-044 1 )1 ) 1 ) 1 f 1 ) ) ) ) ) ) NEW INSPECTORS Y TEST, SIGHT FIRE PROTE)CT,ION , NOTES • ' __�, coy Q GLASS & DRAIN. ' ' ' „ UP TO EXIST. 6"x2 1/2"x2 1/2" R.M.V. 1. APPLICABLE CODES' AND CRITERIAS: z cn NEW 3 CO FL. SW. A. NFPA 13, "STAUDARD';.OR; fiHE INSr�'�';CATION OF SPRINKLER SYSTEMS". z W ' ) N C Ln NEW 3" I.V. W T.SW. j B. NFPA 101, " LIFE SAFETY CODE". m N 0 = Q o EXIST. 6"F.STP. I L C. CHAPTER 4A-3 F.A.C. STATE OR FLORIDA FIRE PREVENTION CODE. 00 rc � (SUPPLIED FROM EXISTING 2 CAPPED 2 CAPPED v � 750 GPM FIRE PUMP LOCATED n FOR FUTURE n FOR FUTURE' D. SOUTH FLORIDA BUILDING CODE - DADE EDITION. a u � - o m ON GROUND FLOOR LEVEL IN EXTENSION EXTENSION �'" EAST WING OF THIS BUILDING.) E. ALL OTHER APPLICABLE LOCAL CODES, ORDINANCES AND THE INSURANCE Z N g 1-1 1 1 UNDERWRITTERS (FM) REQUIREMENTS. a M a o M 2" 2. PROJECT REQUIREMENTS: L — 1 , 2 3„ 1 I 3„ STUB & C P 3 F.SP.L. A. A COMPLETE FIRE SPRINKLER SYSTEM SHALL BE INSTALLED TO PROVIDE FOR FUTURE EXTEN'sml 2"DRAIN RISER DOWN. 1 IN PHASE III OF CONS RUCTION A 100% FULL COVERAGE OF THE AREA WITHIN- SCOPE OF THIS PROJECT, AND TERMINATE AT 6" ABOVE 3" SHALL BE COMPATIBLE WITH THE FLOOR LAYOUT, CEILING rg 1 i TYPE AND ARRANGEMENT. THE WORK INDICATED HEREIN PROVIDES THE MINIMUM GRADE. 2" CAPPED WORK NECESSARY TO COMPLETELY FIRE SPRINKLER THE INDICATED FOR FUTURE , i BUT IS NOT LIMITED T0, ISOLATION ROOMS. THIS INCLUDES, RISERS DRAINS,° EXTENSION I VALVING, PIPING, FITTINGS, SUPPORTS, TESTS AND HEADS. CAPPED CONNECTIONS Z I 1„ HAVE BEEN INDICATED TO REFLECT EXTENSION WORK TO BE PROVIDED ' UNDER A FUTURE FIRE SPRINKLER PROTECTION CONSTRUCTION CONTRACT. N 1" 1" 1 1T" B. NEW CEILING MOUNTED SPRINKLER HEADS SHALL BE FULLY RECESSED, WITH Z to WHITE COVER PLATE. N W N C. LOCATE SPRINKLER HEADS OF TYPE SPECIFIED TO OBTAIN PROPER LL a a N i - COVERAGE. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLANS. z .. z ° I Lu 1 1/4" SPRINKLER HEAD LAYOUT SHALL BE SYMMETRICAL. WHERE � a W - — INSTALLED IN ACOUSTICAL CEILINGS, HEADS SHALL BE PLACED IN a 1 CENTER OF CEILING TILES, UNLESS NOTED OTHERWISE Z o W W L , z Z 1 1 1 D. THE SYSTEM SHALL INCLUDE ALL MATERIALS, ACCESSORIES AND 1 101 ° ul EQUIPMENT NECESSARY TO PROVIDE A SYSTEM COMPLETE AND READY FOR USE. THE SYSTEM SHALL BE INSTALLED TO AFFORD COMPLETE COVERAGE AND BE FREE FROM OPERATING AND MAINTENANCE i DIFFICULTIES, ALL IN ACCORDANCE WITH DESIGN DOCUMENTS. cl) Lu I i E. DEVICES AND EQUIPMENT SHALL BE OF A MAKE AND TYPE LISTED cn I_ - - - - - - -I - - - - - - - L- - - - - - - ! L - BY UNDERWRITERS LABORATORIES AND APPROVED BY INDUSTRIAL RISK - w .� CD INSURERS. IN EACH OF THE NFPA STANDARDS REFERRED TO HEREIN, C _ THE ADVISORY PROVISIONS SHALL BE CONSIDERED TO BE MANDATORY. 4 UJI a PARTIAL SFLOOR EA49T T F. SPRINKLERS SHALL COVER THE ENTIRE AREA OF THE ROOM(S) FIRE INCLUDING ALCOVES. SPRAY SHALL NOT BE BLOCKED BY WALLS OR �,SPRINKLER T PLAN PARTITIONS. bi w C' C- SCALE 1/4"=1'-0" G. SYSTEMS SHALL HAVE FLUSHING CONNECTIONS. o cc W H. PROVIDE AND MAINTAIN A MINIMUM OF 18" CLEARANCE BETWEEN THE BOTTOM OF THE SPRINKLER DEFLECTOR AND THE TOP OF THE o STORAGE, FILE SHELVING, ETC. I. CUT, PATCH, _SLEEVE .&- SEAL EXISTING WALLS IN CEILING, SPACE ABOVE AT NEW PIPE PENETRATIONS. J. SEE ARCHITECTURAL PLAN(S) FOR LIMIT OF WORK IN EXISTING CEILING. FIRE PROTECTION LEGEND K. SEE ARCHITECTURAL PLAN(S) FOR UL LISTED DETAILS OF FLOOR AND SYMBOL ABSREV. DESCRIPTION WALL PENETRATIONS. 3/8" ROD COUPLING --- EXIST. EXIST. PIPE TO REMAIN. 3. SPECIFICATIONS: 3/8" ALL THREAD ROD A. PIPING. F.SP.L. NEW FIRE SPRINKLER LINE PIPE RING o F.STP. FIRE STANDPIPE 1) SIZES 1" TO 2" TO BE "XL" PIPING OR EQUAL. e - QUICK RESPONSE FIRE SPRINKLER HEAD FULLY 2) SIZES 2-1/2" AND LARGER TO BE SCHEDULE 10 BLACK STEEL. RECESSED W/ WHITE COVER PLATE. 3) MINIMUM SIZE FOR PIPING AND TEES TO BE 1". v - QUICK RESPONSE SIDE WALL SPRINKLER HEAD B. SPRINKLER HEADS. 0 HANGER DETAIL g FL.SW. FLOW SWITCH 1) FINISHED CEILING MOUNTED - NEW 1/2" 155'F. VIKING HORIZON MIRAGE ® co � N.T.S. �a I.V. INDICATING VALVE HIGH PRESSURE QUICK RESPONSE CONCEALED SPRINKLER WITH V CEILING MOUNTED COVER PLATE. M � T.SW. TAMPER SWITCH C)2) SIDEWALL MOUNTED - NEW 1/2" 155'F. VIKING BRASS SIDEWALL U- R.M.V. ROOF MANIFOLD VALVE. QUICK RESPONSE HEAD. - NEW TIE-IN TO EXISTING PIPE. 3) ALL NEW HEADS TO BE CENTERLINE OF CEILING TILE IF EXISTING CONDITIONS ALLOW. 4) SPARE HEAD CABINET & WRENCH AS PER N.F.P.A. #13. 0 M ~ 0 w LU C. HANGERS. CD z INDICATING TYPE FLOOR CONTROL 1) ALL HANGERS TO BE AS PER N.F.P.A. #13. 00 M VALVE W/ SUPERVISORY SWITCH, 2) ALL ARM-OVERS, OVER 24" IN LENGTH TO HAVE A HANGER. '� � °, SEE PLANS FOR SIZES. D. FLOW & TAMPER SWITCHES. cn WATERFLOW SWITCH 0 1) ALL FLOW & TAMPER SWITCHES TO BE SINGLE POLE, DOUBLE THROW. N c c� HANGER ROD TO STRUCTURE FEED . MAIN, SEE PLANS FOR SIZES. �APPRM/ED FOR 0 m UIL I�l P 6,ef1}T<'la°? , P"H_ POSES C NIPPLE 4" BY il33A"�� mD��DE C ' i.° °' . W L.�ED-11I ° .t.r _ � N MAXIMUM LENGTH SPRINKLER BRANCH - �- _.i"4. W Lr STANDPIPE RISER r -.� . TO SPRINKLER SYSTEM a --O s r A�S�ES`_ r .i�s' P'. 4 e,N C_.� -_. �- j 1 INSPECTORS TEST VALVE-­\ / - 0 1" AUXILIARY `�' ` w DRAIN VALVE Q o W ° �— 1" DROP NIPPLE 1" SIGHT GLASS LOCATION OF EXISTING CONCEALED TYPE 1" x 1/2" REDUCER FIRE PUMP ON GROUND SPRINKLER HEAD FLOOR LEVEL _ 2" DRAIN RISER. 1" UNION W BRASS ORIFICE � = SEE PLANS FOR / ­ BRASS W E EQUAL TO DIS �'�- ¢ '•. "� `` LOCATION. / HOLE - LOCATION OF WORK Q CHARGE FROM THE SMALLEST ON. SIXTH FLOOR %,; ,v 0` ,,,��' SPRINKLER ORIFICE IN THAT FLOOR. LEVEL FOR THIS PROJECT. DESIGN ,T.c.R.' CEILING COVER PLATE FINISHED CEILING DRAWN IN WHITE FINISH EAST TOWER A.R. BUILDING CHECKED 0.A,_ SCALE i AS SHOWW DATE 08-04-98 PROJ. No. `� FLOOR CONTROL VALVE WITH 2OW17 SPRINKLER ARM OVER DETAIL TEST � SHEET No. N.T.S. INSPECTORS TEST CONNECTION KEY PLAN - EAST TOWER N.T.S. FIRE PR®TECTO®N PLAN, NOTES, LEGEND AND DETAILS OF