00-0883-042
) ) , / U a w CO) NOTE: PER bETER PART?TIONS)'AT INTEIISTIVAL Z W SPACE MUST BE SEAL'_D AND ANY EXISTING W 11) SEE MECH. DWGS. FOR DIM. OPEN)MS kbtktb )OU r)WITH GYP.) BD: AND DET. OF DUCTWORK AND TAPED AND COMPOUNDED AS REQ.TO INSURE a' �' NEW MECH. AIR PLENUM. PROPER ROOM ISOLATION FROM SURROUNDING + m N CO EXISTING CONC. AREAS. TYP. FOR ALL PERIMETER WALLS OR EXISTING CONC. {/� t Q 0 SLAB ABOVE AS INDICATED IN FLOOR PLANS. co W +0 Q O� 3EMECH. DWGS. FOR DIM. -REFER TO FLOOR PLANS FOR PARTITION SLAB ABOVE GOOSENECK. CONSTRUCT OF AND DET. OF DUCTWORK AND CLOSURE DETAILS V Q O ,Lo 22 GAUGE ALUMINUM. SEE MECH. DWGS. NEW MECH. AIR PLENUM. J LL EXIST. UNIT MOUNTING = Z \ CURB SECURED TO C NEW WD. NAILERS SEALING MATERIALS MUST BE Q Q O CONTINUOUS ON THE PERIMETER c+) UNIT PERIMETER PARTITIONS ABOVE SELF-FLASHING UNIT CEILING LEVEL MUST BE SEALED AND ANY EXISTING OPENINGS BLOCKED OUT WITH GYP. BD. N0. 10 S.S. SHEET MTL. SCREWS 9'-O" . TAPED AND COMPOUNDED AS REQ. THRU SEALANT WASHERS @ 8" O.C. A.F.F. TO INSURE PROPER ROOM ISOLATION FROM SURROUNDING ST. STL. COUNTER FLASHING AREAS. TYP. FOR ALL PERIMETER MODIFIED BITUMEN BASE FLASHING WALLS Q © WOOD CANT STRIP (WRAP ARRUND TOP OF CURB) Z N MODIFIED BITUMEN ROOF MEMBRANE -HOT N 8" MOP OVER EXISTING ROOFING FELTS EXISTING INSULATION -PATCH AS REQUIRED TO INSURE TIGHT FIT AGAINST BLOCKING ° c z a n N Ln m 04 W CC n M N w LJ I Q d EXIST. CONC. DECK Q N LL d F M W a v yZj S2 z N p o = LY 4" P.T. WD. CANT SECURED a a TO NAILERS WITH # 14 a ACCESSORY ROOF CURB WITH H.D. ROOF FASTENERS w DAMPER TRAY ANGLE SUPPORT. ( ) 8'-O" A F.F. \ \ ��1 P.T. WOOD NAILER MIN. 2X6 — Z < W EQUAL TO INSULATION THICKNESS / / g w Ed Z ANCHORED TO EDGE OF ROOF OPENING W/ 2'-4" m #14/ WASHER 012- O.C.( STAGGERED) V � CUT OPENING THROUGH EXISTING ROOF SLAB P.T. WOOD NAILER (MIN. 2X6) SET IN I BETWEEN EXISTING PRECAST CONC. JOISTS MASTIC ANCHORED TO CONC. ROOF NEW ACOUST. PANEL TO BE -COORDINATE WITH MECHANICAL DRAWINGS SAW-CUT BACK TO ACCOMODATE WITH 5"X1/2"0 ANCHOR BOLTS (MIN) l FOR OPENING/DUCT SIZE W/ WASHERS @ 16" O.C. (STAGG) NEW PORTABLE AIR CLEANER (2" MIN. INTO CONC. DECK) UNIT DUCTWORK. SEE NOTE. 10" / U W T. 0 0 W 'G. O ; t ko 13 o m o W 3 o GOOSE NECK ROOF PENETRATION DETAIL I I EXIST. PARTITION N.T.S. TO REMAIN. XIST. PARTITION TO REMAIN. NEW PORTABLE AIR CLEANER (SCU-30N-4T) UNIT TO BE FASTENED TO NEW PORTABLE AIR CLEANER (SCU-30N-4T) METAL FRAME. UNIT TO BE FASTENED TO METAL FRAME. I MOUNTING PLATE MOUNTING PLATE FURNISHED WITH FURNISHED WITH AIR CLEANER UNIT. AIR CLEANER UNIT. 0 n �J 0 co DETAIL OF AIR CLEANER UNIT DETAIL OF AIR CLEANER UNIT �C ICU 3"=1 '-0" 1 ` 1 ENDOSCOPY 3"=1 '-0" 1 W V� ch > EXISTING STUCCO EXISTING STUCCO O EXISTING CONCRETE WALL TO REMAIN a 1 LINE OF EXISTING EXISTING CONCRETE SPANDREL BEAM TO REMAIN I I CONC. SLAB ABOVE O Ce) NEW STUCCO TO MATCH EXISTING EXIST. 1 HR. FIRE-RATED/SMOKE W 0 PROOF PARTITION. ® W SEALANT Q NEW STUCCO TO MATCH EXISTING I I NOTE: SEE TYP. NOTE REGARDING SEALANT Q I I ROOM ISOLA11ON CONDITION. O FLASHING TAPE ' ' Q SEALANT BED '� 0 O METAL WALL CAP FLANGE Q METAL WALL CAP FLANGE V.r NEW 3 5/8" GALV. MTL. NOM. 2X4XN0. 22GA. J 22 GA. GALVANIZED STEEL WALL CAP I STUD FRAME. c 22 GA. GALVANIZED STEEL WALL CAP (OR HEAVIER) STEEL ANGLES O = FASTEN SLEEVES W/ 2 SHEET METAL SEE MECHANICAL DWGS FOR DUCT WORK / /� I DUCT TO ALL 4 SIDES OF ® QO SCREWS AT TOP AND BOTTOM -ADJUST TO SOFFIT CONDITIONS FASTEN SLEEVES W/ 2 SHEET METAL / / SEE MECHANICAL DWGS FOR DUCT WORK ON BOTH SIDS OF WALL N SEE INTERIOR ELEVATIONS �� SCREWS AT TOP AND BOTTOM ( I I -ADJUST TO SOFFIT CONDITIONS W/ N0. 8 SHEET METAL SCREWS �p WALL CAP UNIT W/ BACKDRAFT-BIRD SCREEN I SEE INTERIOR ELEVATIONS COMPONENTS OVER MASONRY OPENING WALL CAP INLET SLEEVE WALL CAP UNIT W/ BACKDRAFT-BIRD SCREEN SEE MECHANICAL DRAWINGS WALL SLEEVE -EXTEND SIX INCHES OUT COMPONENTS OVER MASONRY OPENING /I WALL CAP INLET SLEEVE O Z cn 00 FROM ADJACENT WALL PROJECTION SEE MECHANICAL DRAWINGS / I I I WALL SLEEVE -EXTEND SIX INCHES OUT � w p m / FROM ADJACENT WALL PROJECTION ( I I I W Q E U O 61 0 C) 0 T EXISTING 5/8" GYP. BD. V) E w I — TO BE SAW-CUT. = J a w PATCH OPENING TO I I ( I W SEALANT BED I I I I M MATCH EXISTING FINISH f I I I I a ACOUSTICAL CEILING PANELS o o NEW STUCCO TO MATCH EXISTING W NEW A/C RETURN DUCTWORK. I oI oI z� NEW STUCCO TO MATCH EXISTING Q p I ,� ,e ,►., + SEE MECH. DWGS. Q CUT OPENINGTHROUGH MASONRY WALL BELOW EXISTING Q CONCRETE SPANDREL BEAM. PROVIDE 8" X 8" CONCRETE 8 X 8' CONC. BAND � ..• ..� ,. •••••-, a' �,, AROUND MASONRY OPENING 4 I BAND REINF, WITH 1 # 5 CONT. TIE INTO SPANDREL .l Q WITH 1# 5 BAR DRILLED 5" INTO CONCRETE AND EPDXIED Q I ACOUSTICAL CEILING SOFFIT EXIST. 1 HR. FIRE-RATED/SMOKE PROOF PARTITION. y' "• e,d'� EXISTING STUCCO EXISTING STUCCO EXISTING MASONRY WALL I I (n 'rte sell', EXISTING CONCRETE WALL W FIRESTOP SYSTEM PACKING MATERIAL DESIGN MIN. 2 1/4" THICK OF.MIN. 4.0 PCF MINERAL WOOL BATT INSULATION PACKED INTO OPENING AS A DRAWN * PATCH OPENING TO PERMANENT FORM. FILL, VOID OR CAVITY MATERIAL -CAULK- CHECKED MATCH EXISTING FINISH MIN. 3/4" THICK FILL MATERIAL APPLIED WITHIN THE ANNULUS W/ A MIN. 1/4" DIA. BEAD OF FILL MATERIAL APPLIED © WALL/DUCT INTERFACE ON BOTH SC_AS NOTED SURFACES OF WALL. PRODUCT MUST BEAR U.L. CLASSIFICATION MARKING. DATE . . . . . . . . . . . . 8-4-98 PROJ. No. 9736 WALL CAP DETAIL 4 WALL CAP DETAIL EXISTING HEADER SHEET No. EMERGENCY N.T.S. N.T.S. TYP. N. U.L. SYSTEM N0. W—L-7012 DETAIL OF MECHANICAL DUCTWORK 2 ENDOSCOPY 3"=1 '-0" A - 7