00-0883-041 oc cli 1= a W 2E N I-- > > z W L0 T� ' , � � N GWC M PERIMETER PARTITIONS AT INTERSTITIAL ' SPACE MUST BE SEALED AND ANY EXISTING I I PERIMETER PARTITIONS AT INTERSTITIAL + m ch OPENINGS BLOCKED OUT WITH GYP. BD. I I SPACE MUST BE SEALED AND ANY EXISTING TAPED AND COMPOUNDED AS REQ.TO INSURE I I OPENINGS BLOCKED OUT WITH GYP. BD. W C 0) PROPER ROOM ISOLATION FROM SURROUNDING I I TAPED AND COMPOUNDED AS REQ.TO INSURE AREAS. TYP. FOR ALL PERIMETER WALLS OR I I EXISTING CONC. PROPER ROOM ISOLATION FROM SURROUNDING � LO AS INDICATED IN FLOOR PLANS. I I SLAB ABOVE AREAS. TAP. FOR ALL PERIMETER WALLS OR PARTITION AS INDICATED IN FLOOR PLANS. EXISTING CONC. W J � � � -REFER TO FLOOR PLANS FOR PAR I I CLOSURE DETAILS -REFER TO FLOOR PLANS FOR PARTITION SLAB ABOVE �-- �p I CLOSURE DETAILS NOTE: I I V p \ SEE MECH. DWGS. FOR DIM. I I AND DET. OF DUCTWORK AND I I Q M Q p NEW MECH. AIR PLENUM. I I I I g ^ M I I NOTE: PERIMETER PARTITIONS ABOVE SEE MECH. DWGS. FOR DIM. I I I CEILING LEVEL MUST BE SEALED AND DET. OF DUCTWORK AND I I AND ANY EXISTING OPENINGS NEW MECH. AIR PLENUM. I I BLOCKED OUT WITH GYP. BD. --- -------- ----------- ------ I I TAPED AND COMPOUNDED AS REQ. 9.-C)" I I TO INSURE PROPER ROOM _ A.F.F. I I ISOLATION FROM SURROUNDING I I AREAS. TYP. FOR ALL PERIMETER z I I WALLS Q 55 NEW RECESSED 5/8" TYPE 'X' G.W.B. ON 2 1/2" 20 GA. MTL. CHANNEL FRAME. to SAW-CUT FOR DUCT PENETRATIONS W r- N to to C3 I I SEAL AS REQ'D. d cc a N M LL a a d N Wo to 4 ca o ¢ — — — — — — — — — — — — — — — J W a en zd < C=9 ................................................ a . . .......... — �' zz z 8'-0" A.F.F. ---1-------- NEW 12" X 18 .METAL / p m --I— En NEW TYPE 'X' ACCESS DOOR. 2'-4" I 5/8" G.W.B. SOFFIT SEE SHOP DWGS. FOR \ ON 2 1/2" 20 GA. DETAILS AND DIMS. / I ' 1 I MTL. CHANNEL FRAME �I � @ 16" O.C. W/ FIN. NEW ACOUST. PANEL TO BE ' I I TO MATCH EXIST. CLG. I I I W SAW-CUT BACK TO ACCOMODATE NEW PORTABLE AIR CLEANER \ UNIT DUCTWORK. SEE NOTE. � N 10" / \\ / FPM N / � _ �- a j W LY I LINE OF EXIST. CEILING. o ko 0 _ 0 "' Z EXIST. PARTITION TO REMAIN. NEW PORTABLE AIR CLEANER NEW PORTABLE AIR CLEANER I I I I UNIT (SCU-30N-4T) TO BE (SCU-30N-4T) FASTENED INTO MTL. FRAME UNIT TO BE FASTENED TO I I MOUNTING PLATE SEE MECH. DWGS. FOR METAL FRAME. I I I I FOR DETAILS AND DIMS. FURNISHED WITH AIR CLEANER UNIT. I I MOUNTING PLATE DETAIL OF AIR CLEANER UNIT —TYP. �Jl OR RECOVERY EXIST. PARTITION — I TO REMAIN. I ER O DOC � — DETAIL OF AIR CLEANER UNIT 2 CIO cl) EMERGENCY M � A2 ® _j Z cri � V W O � ® Lu _ Z z Oa FRONT VIEW SECTION A-A J a as a ° as a a 0V N 4. 4 cn (0 1 � cn Z v) 2 EXISTING CONC. EXISTING CONC. I I o ° o SLAB OVERHEAD SLAB OVERHEAD I I a I I � 16 GA. GALV. PARTITIONS MUST BE SEALED AND EXISTING v Q MTL. J TRACK I I OPENINGS (IF ANY) BLOCKED OUT W = " SUM 3/8" REDHEADS I I W/ NEW GYP. BD. TO MATCH EXISTING Q U J 3/8 REDHEADS 5/8 GYP I I AND TAPED & COMPOUNDED AS REQ. Q W 1 8 WASHERS ~ W/ 1/8" WASHERS SHAFT WALL LINER / ,/ I I TO INSURE ROOM ISOLATION FROM > w @ 12" O.C. W/ 1/4" STEEL SELF @ 12 O.C. ki ki TAPPING SCREWS SURROUNDING AREAS. D' N 5/8" TYPE 'X' GYP. BD. I I COLD ROLLED CHANEL rn °o = STEEL C-H STUDS �- 5/8 GYPSUM I I LO I I ZV) METAL STUD PARTITION @ 24" O.C. WALLBOARD I I METAL FURRING CHANEL Ln d Q c T TO MATCH STUD BELOW -SPACE @ 16" O.C. — — ------- ------------ - i 3 4 INTERSTITIAL SPACE INTERSTITIAL SPACE I I � ROOM SIDE ROOM SIDE I I � J I I ... ., o. I I .... A I I CONT. TAPE AND I I JOINT COMPOUND NEW 5/8" TYPE 'X' G.W.B. CEILING Q ;,y'•. �' �� ``�.`� W/ MTL SUSP. W ,O, "i',``•�� FIRE-RATING . GYPSUM BOARD CEILING EXISTING CEILING LINE TO REMAIN. I I AND FINISH TO MATCH EXISTING. (n 1. GYPSUM WALL ASSEMBLY (1 HR ) I I DESIGN 2. PIPE OR CONDUIT TO BE OF THE FOLLOWING A. MAX. NOM. 4" DIA. STEEL ELECTRICAL METALLIC TUBING. I DRAWN .�: I EXISTING PARTITION B. MAX. NOM. 6" DIA. COPPER TUBING (TYPE 'L' OR HEAVIER). C. MAX. NOM. 1" DIA. FLEXIBLE STEEL CONDUIT. — — — — — — — — — — — — I I TO REMAIN. I CHECKED • MAX. 1 PIPE OR CONDUIT PERMITTED IN THE FIRESTOP SYSTEM. Al 111111111111111111111111 • PIPE OR CONDUIT TO BE INSTALLED NEAR CENTER OF STUD CAVITY I I I I ...... SCALE WIDTH & TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF ASSEMBLY AS NOTED 3. 3M FIRE BARRIER CP 25WB+ INTUMESCENT LATEX-BASED CAULK FORCED INTO ANNULAR SPACE TO MAXIMUM EXTENT. EXISTING EXISTING 4. MIN. 1/4" BEAD 3M FIRE BARRIER CP 25WB+ INTUMESCENT CAULK PARTITION PARTITION DAZE 8-4-98 / PROJ. No. AT PIPE/GYPSUM WALLBOARD INTERFACE. 9736 MAX. PIPE/CONDUIT DIA. (IN.) ANNULAR SPACE (IN.) SHE o. 1 0" TO 3/16" 4 0" TO 1/4" U.L. DES. U438 DETAIL OF NEW GYP. BD. CEILING DETAILS RECOVERY SMOKE PARTITION SMOKE PARTITION A - 6 PENETRATION THROUGH GYPSUM WALL ASSEMBLY ] 4 N.T.S.