00-0883-034 V = a W w > > > CO) 2E LLJ licown N m CONSTRUCTION/DEMOLITION KEYNOTES + +U1 PHARMACY W STORAGE ~ q LO 0 INSTALL NEW MASK AND GLOVE STATION TO BE FURNISHED BY W J O� OWNER. LL 2 LV. SOLUTIONS ROOM GENERAL NOTES z c 0 EXISTING GLASS DOOR TO REMAIN. PROVIDE A NEW AIRTIGHT SEAL STAIR DRUGS = Z AND A DOOR CLOSER. SEE DOOR SCHEDULE. (.� F o Fl AS PART OF THE PRESENT SCOPE OF WORK, LO INSTALL NEW OWNER-FURNISHED AIR CLEANER UNIT (MEDAIR GENERAL CONTRACTOR SHALL INSPECT ALL PERIMETER n M SCU-30N-4T) PER MANUFACTURER'S INSTRUCTIONS. SEE BALCONY ° ° PARTITIONS ABOVE THE CEILING LEVEL TO INSURE THE FOLLOWING:qH) MECHANICAL DRAWINGS. COR IDOR Allsh 0 KIM o A.) ALL PARTITIONS ABUTT THE CONCRETE SLAB ABOVE O DASHED LINES INDICATE LOCATION OF PATIENT STRETCHER. 3 T � AND ARE PROPERLY SEALED FROM FLOOR BASE TO CEILING SLAB. Is L TI N WHERE SEALED PARTITION IS NOT FOUND, CONTRACTOR INSTALL NEW OWNER-FURNISHED SURFACE-MOUNTED CONTROL IN-PATIENT Nu. A. SHALL REMEDY THE EXISTING CONDITION BY PROVIDING A O SYSTEM AND SURFACE-MOUNTED PRESSURE SENSOR. o CONTINUOUS METAL STUD PARTITION W/ 5/8" TYPE X' ❑ T. OUT-PATI ON EA. SIDE. Os DASHED LINE DENOTES PERIMETER PARTITIONS THAT MUST ABUTT 0 - NU. STA. B.) ALL DUCT PENETRATIONS, ELECTRICAL CONDUITS, cc THE CONCRETE SLAB ABOVE AND MUST BE PROPERLY SEALED FROM I 1 ' S.0 PLUMBING PENETRATIONS, ETC. ARE PROPERLY SEALED. a FLOOR BASE TO CEILING SLAB. IF A PARTITION DOES NOT CONTINUE -------T---------- ------- C.) ANY EXISTING WALL OPENING(S) OR UNSEALED z ABOVE THE FINISHED CEILING, OR IF A PORTION OF IT IS MISSING, I I II - CORRIDOR PENETRATIONS TO BE BLOCKED W/ GYP. BD. (TAPED - co CONTRACTOR SHALL EXTEND THE PARTITITION TO THE UNDERSIDE OF I AND COMPOUNDED) AS REQUIRED TO INSURE ROOM THE STRUCTURE USING METAL STUDS WITH 5/8" TYPE "X" G.W.B. ON I I ROOF ISOLATION FROM SURROUNDING AREAS. EACH SIDE. R E C I 8 I J.C. D.) GENERAL CONTRACTOR SHALL PROTECT EXISTING AREAS °z to SOIL. IN-SERV. n N Ln SEE DET. 5/A-6 1 OF NEW dIR 9 I Nu. OFF. ADJACENT TO WORK AREAS. ANY EXISTING FINISHES DAMAGED UJ n n M -. N D I CLEANER (UNIT. s u. o NU. TOIL. DRS. TOI DUE TO WORK PERFORMED SHALL BE REPAIRED OR REPLACED J a w w EXISTING EXTERIO I I I Nu. & SH. & SH. TO MATCH EXISTING AT NO ADDITIONAL COST TO OWNER. a a a a a N Co PATCH DOOR JAMB AND HEADER AS REQUIRED AND PAINT TO A3 CONCRETE WALL. I 1 4 SCOPE OF WORK RECOVERY STA. ISOL. RM. E. GENERAL CONTRACTOR TO PROVIDE A PERMIT FOR d F .-. MATCH EXISTING AND FLOORING. I I II _ q-6 C.U. NU. LKR. RM. ) w < S2 W LO I DRS. TRANSPORTATION AND DISPOSAL OF DEBRIS (IF REQUIRED). � en M s0 REMOVE EXIST WALL HUNG UNIT. REFINISH WALL FINISH TO MATCH 3 4 2 I I Q ❑ LKRS. F.) GENERAL CONTRACTOR SHALL SUBMIT TO THE OWNER/ a � a Lu EXISTING. I _ T. ARCHITECT A SCHEDULE FOR DEMOLITION PROCEDURE w 8 a 1 A4.1 1 2 AND OPERATIONAL SEQUENCE FOR REVIEW AND APPROVAL. a 0 REMOVE EXISTING FOLDING GLASS/ALUMN. DOOR, FRAME, AND I I II ' NU. LOUNGE z 4, zw TRACK. I _ LKRS. G.) GENERAL CONTRACTOR SHALL SUBMIT A SCHEDULE d o W J ANES. OFF. ANES. n _ 9 -1 I SUP. SHOWING THE DAY, AREA, AND MEANS OF TRAVEL THROUGH a ® 5 o m I PREMISES FOR DISPOSAL OF DEBRIS FOR OWNER'S APPROVAL. 7 I I I STAIR STERILE CORRIDOR W NOTE: ALL PLUMBING, CASEWORK, FURNITURE, AND EQUIPMENT II I LITTERS SHOWN ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. _ INST. _� P= STER. LC, (~/� CAM 0.R. #1 fA A.H.U. #8 SCRUB O R #Z ISOL. O.R. #7 _ TRANS. J Q=+ W g Q W 6 � E- � �- 1 5 SURGERY 'S sue, SL mow.. y n � y a ELECT. �.\'fil�sT!t`'7G .1'�` 14?�'f'i � ti� �7i�i�.. it j-. ��.: ,�L 3 C r^•'-•/' I l i"t :1 i� 1 �iJ i:�IJtL1F 4i S 0` `1'\!S T i':<\.1- 1.\�..i'J r f Jai' � C J !'r �a 1 t �! ~� � c+ C0CIrIP,4�NCIES, AS S}_i FO R1 H IN THE t 9:�l � Z A4.1 r3�� a LIFE SAFETY CODE. 3 Lu Z 01' byF� r , o 3 ISOLATION ROOM FLOOR PLAN V"Jy SCALE: 1/2'_1'-O• RECOVERY _-''Q ^; 7 120.00 SQ. FT. 2nd FLOG R-MAIN/PAVILION BUILDING T"; Ul ISOLATION ROOM LOCATION PLAN R �ti�z<ar SCALE: 1/16•=r-0• RECOVERY LUC AIIATER k L L ry�r .• CELING PLAN KEYNOTES CEILING DEMO KEYNOTES z O REMOVE EXISTING CURTAIN METAL TRACK. SAVE FOR O REINSTALLATION. O REINSTALL EXISTING LIGHT FIXTURE. O EXISTING DIFFUSER TO REMAIN. SEE MECHANICAL DRAWINGS. M co d O NOT USED. O REMOVE EXISTING DIFFUSER. SEE MECHANICAL DRAWINGS. �/�n- j W O NOT USED. 6 � !!s � 0 REMOVE EXISTING RETURN GRILLES . SEE MECHANICAL DRAWINGS. 0 J Z O PROVIDE AND INSTALL NEW SUPPLY GRILLE (SEE MECHANICAL O NOT USED. LL O DRAWINGS.) Q3 H Os REMOVE EXISTING LIGHT FIXTURE. SAVE FOR REINSTALLATION. V 5 RELOCATED SUPPLY GRILLE. 0 REMOVE EXISTING LIGHT FIXTURE. SAVE FOR RELOCATION. Os INSTALL NEW OWNER-FURNISHED AIR CLEANER UNIT (MEDAIR ; 11 0 REMOVE EXISTING SPRINKLER HEAD COVER. SAVE FOR m SCU-30N-4T) PER MANUFACTURERS INSTRUCTIONS. SEE N / I REINSTALLATION. C Q MECHANICAL DRAWINGS. _ �- ' II O DASHED LINES INDICATE EXISTING FOLDING GLASS/ALMN. DOOR, W 0 O NOT USED. - - - u 2 FRAME AND TRACK TO BE REMOVED. ® 1 _ 10 EXISTING LIGHT FIXTURE TO REMAIN. Os NOT USED. \ 3 O O PATCH DOOR JAMB & HEADER AS REQUIRED. FINISH TO MATCH — 11 EXISTING EXHAUST TO REMAIN. EXISTING. II 12 EXISTING FIRE SPRINKLER HEAD COVER TO REMAIN. M O C 10 REINSTALL EXISTING FIRE SPRINKLER HEAD COVER. 4 N ' II 13 EXISTING DRYWALL CEILING TO REMAIN. ^ ~ J _� ® I I u 11 PROVIDE AND INSTALL NEW 12" X 18" METAL ACCESS PANEL. � 13 � 12 PROVIDE AND INSTALL NEW CURTAIN METAL TRACK. V? O 0 4 II ® o N = II 12 CEILING DEMO LEGEND N I I u 101 REMOVE EXISTING GYP. BD. CEILING J INCLUSIVE OF METAL FRAME. cn z Zwzo 1 I I 0 �- 4 11 � oQC II I UU � ° al CEILING PLAN LEGEND ❑ ■ cn w wva =D � o = cn INSTALL NEW GYP. BD. CEILING WITH METAL Q U m CHANNEL FRAME TO MATCH EXISTING TO N REMAIN. w N r� Q NOTE: ALL ITEMS SHOWN ON DEMOLITION CEILING PLAN ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. °o 0 0 w rn oLO Q Ln lc - uj_ cl ISOLATION ROOM CEILING DEMO. PLAN! = = 2 SCALE: 1/2'.1'-O• NOTE: ALL ITEMS SHOWN ON CEILING PLAN ARE.EXISTING TO REMAIN ISOLATION ROOM CEILING PLAN RECOVERY o y Y UNLESS NOTED OTHERWISE. 4 SCALE: 1/2'=1'-O• RECOVERY V) T, I� tt DESIGN DRAWN CHECKED SCALE AS NOTED DATE 8-4-98 PROJ. No. 9736 SHEET No. RECOVERY ISOLATION RM. PLANS AM 4=mj