00-0883-030 i > > cl CL CONSTRUCTION/DEMOLITION KEYNOTES A2.1 � N ' W Z N 5 3 Lu z W > W LLLO O INSTALL NEW MASK AND GLOVE STATION TO BE FURNISHED BY OWNER. � N DC CO CO Li Li z EXISTING WOOD DOOR TO REMAIN. PROVIDE A NEW AIRTIGHT SEAL ° ' ° ' ° ' ° ' ° ' ° ' ® ' ° ® ' M N O AND A DOOR CLOSER. SEE DOOR SCHEDULE. co W 00 0 0 O INSTALL NEW OWNER-FURNISHED AIR CLEANER UNIT (MEDAIR E 1 - -PRIVATE ' + La SCU-30N-4T) PER MANUFACTURER'S INSTRUCTIONS. SEE Evi. OFFICE I-1 �� V Q O I I I J 3 LL MECHANICAL DRAWINGS. I o L J L J _ Q y O DASHED LINES INDICATE LOCATION OF PATIENT STRETCHER. LO INSTALL NEW OWNER-FURNISHED SURFACE-MOUNTED CONTROL U C 0 5 ° ° ° i � i I pp� � Q (� O SYSTEM AND SURFACE-MOUNTED PRESSURE SENSOR. 2 GENERAL NOTES O DASHED LINE DENOTES PERIMETER PARTITIONS THAT MUST ABUTT � 901, AS PART OF THE PRESENT SCOPE OF WORK, THE CONCRETE SLAB ABOVE AND MUST BE PROPERLY SEALED FROM I NURSES GENERAL CONTRACTOR SHALL INSPECT ALL PERIMETER FLOOR BASE TO CEILING SLAB. IF A PARTITION DOES NOT CONTINUE _ T STATION o PARTITIONS ABOVE THE CEILING LEVEL TO INSURE THE FOLLOWING: ABOVE THE FINISHED CEILING, OR IF A PORTION OF IT IS MISSING, I ` CONTRACTOR SHALL EXTEND THE PARTITITION TO THE UNDERSIDE OF _ �^ so��-� ��� A.) ALL PARTITIONS ABUTT THE CONCRETE SLAB ABOVE ���� AND ARE PROPERLY SEALED FROM FLOOR BASE TO CEILING SLAB. THE STRUCTURE USING METAL STUDS WITH 5/8" TYPE "X" G.W.B. ON _ 4 GPaQ�c VESTIBULE WHERE SEALED PARTITION IS NOT FOUND, CONTRACTOR w EACH SIDE. I j y Q��s� SHALL REMEDY THE EXISTING CONDITION BY PROVIDING A F CONTINUOUS METAL STUD PARTITION W/ 5/8" TYPE X' Q Z E� �S ON EA. SIDE. Q R EXAM & TREAT. �� cP ROOM WAITING N PROVIDE & INSTALL ADHESIVE JAMB WEATHER-STRIPPING AT I _ _______ Z __---- _ - ^ o c°�� c�" �� B.) ALL DUCT PENETRATIONS, ELECTRICAL CONDUITS, WINDOWS TO INSURE PROPER ROOM ISOLATION. (� a �, �s°�P° �" ` o�R\Opc� oF� PLUMBING PENETRATIONS, ETC. ARE PROPERLY SEALED. I ^ o I w z g osc°e�^ o °FF��^ `�� C.) ANY EXISTING WALL OPENING(S) OR UNSEALED o I I z w _ ���°� ` �°e� PENETRATIONS TO BE BLOCKED W/ GYP. BD. (TAPED z rn n N Ln L.l_J 1 I o ^ ° P� o e. ��°a� ^v v AND COMPOUNDED) AS REQUIRED TO INSURE ROOM 111 .- N �°vi> i ISOLATION FROM SURROUNDING AREAS. d a w w Al CC NOTE: ALL PLUMBING, CASEWORK, FURNITURE, AND EQUIPMENT I A2.1 2 I _ ��oo �^ y D.) GENERAL CONTRACTOR SHALL PROTECT EXISTING AREAS a a a LL Q N SHOWN ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. I I 6 �`i j i os°P i ADJACENT TO WORK AREAS. ANY EXISl1NG FINISHES DAMAGED 6 _j z v vo,��o`/� DUE TO WORK PERFORMED SHALL BE REPAIRED OR REPLACED . i a W Lu LO M ————————————————————— - l TO MATCH EXISTING AT NO ADDITIONAL COST TO OWNER. s ��y c " v a G7 m LU !—LU Lu I E.) GENERAL CONTRACTOR TO PROVIDE A PERMIT FOR TRANSPORTATION AND DISPOSAL OF DEBRIS (IF REQUIRED). °�a a N � _ ^ z 6 o w F.) GENERAL CONTRACTOR SHALL SUBMIT TO THE OWNER/ d `` °z J I I V2�RO�� ARCHITECT A SCHEDULE FOR DEMOLITION PROCEDURE o m _ /] AND OPERATIONAL SEQUENCE FOR REVIEW AND APPROVAL. r G.) GENERAL CONTRACTOR SHALL SUBMIT A SCHEDULE U I SHOWING THE DAY, AREA, AND MEANS OF TRAVEL THROUGH ~' E /T - SCOPE OF WORK PREMISES FOR DISPOSAL OF DEBRIS FOR OWNER'S APPROVAL. 2 Lu ca I I _ 4 —6 EXISTING PORTIONS OF BUILDING SHALL 7 7 COq c'L'(Vr11 I i i THE PROVISIONS OF EXISTING a� I I OCCUPAir!CiES, AS SET FORTH IN THE 1991 ,� W a °� W NFPA 101 LiFE SAFETY CODE. cti �'o = 6TH FLOOR -EAST TOWER ) � ISOLATION ROOD LOCATION PLAN ` `�" SCALE: 1/18'=1'-0' -;,- ,T- ENDOSCOPY ._��. �' ��` ui G?L�1 �Vv 4y I I rayci G ui �zi r,:i2:CiJOT O I I I I I I 3 ISOLATION ROOM FLOOR PLAN SCALE: 3/4'=1'-0' � n c �� '+k.t p� �a �'s�i ? ENDOSCOPY s VNIATE CELING PLAN KEYNOTES CEILING DEMO KEYNOTES i O REINSTALL EXISTING LIGHT FIXTURE. O RELOCATED LIGHT FIXTURE. l �� I O REMOVE EXISTING METAL CURTAIN TRACK. " 3 PROVIDE AND INSTALL NEW ARMSTRONG MYLAR FILM-FACED O 9 I O EXISTING DIFFUSER TO REMAIN. SEE MECHANICAL DRAWINGS. I FIRE-RATED (CLASS A) ACOUSTICAL CEILING PANELS. - O NOT USED. O PROVIDE AND INSTALL NEW SUPPLY GRILLE (SEE MECHANICAL O REMOVE EXISTING RETURN GRILLES . SEE MECHANICAL DRAWINGS. + O DRAWINGS.) \ ON I \ O REMOVE EXISTING EXHAUST. SEE MECHANICAL DRAWINGS. c 5 RELOCATED SUPPLY GRILLE. \ B 0 REMOVE EXISTING LIGHT FIXTURE. SAVE FOR REINSTALLATION. LU OINSTALL NEW OWNER-FURNISHED AIR CLEANER UNIT (MEDAIR O REMOVE EXISTING LIGHT FIXTURE. SAVE FOR RELOCATION. SCU-30N-4T) PER MANUFACTURERS INSTRUCTIONS. SEE \ MECHANICAL DRAWINGS. INSTALL NEW OWNER-FURNISHED FEAU-1 UNIT PER REMOVE EXISTING CEILING MOUNTED SPEAKER. SAVE FOR J O O REINSTALLATION. �_ 0 MANUFACTURER'S INSTRUCTIONS. SEE MECHANICAL DRAWINGS. 0 � t Os REINSTALL EXISTING ACOUSTICAL CEILING PANELS. ® Q c Os REINSTALL EXISTING CORRIDOR SPEAKER. CEILING DEMO LEGEND �o DASHED LINES INDICATE APPROXIMATE LOCATION OF ROOF - co PENETRATIONS ABOVE CEILING. I I O SAWCUT EXISTING GYP. BD. CEILING W I - -- - - INCLUSIVE OF METAL FRAME. _ -- -- / Z O. � CEILING PLAN LEGEND I /// I c INSTALL NEW GYP. BD. CEILING WITH METAL T 1'_6" T CHANNEL FRAME TO MATCH EXISTING. I / ' I 3A �cn J � 2 I o N = I I I o t 4 I � _ PANELS. TEMPORARILY UREMOVE CPORTIONS OF CEILING GRID AS REQUIRED TO ALLOW z0 z z FOR DUCT INSTALLATION AND SAVE FOR I I REINSTALLATION. SEE MECHANICAL o 0 p Q N E -I � vL N NOTE: ALL ITEMS SHOWN ON CEILING PLAN ARE EXISTING TO REMAIN 3 6 _ -- -- _ UNLESS NOTED OTHERWISE. I _ - I - -- o = < a / Q U Lam,_ I / I 2 > w F-Z//-, / N ° / REMOVE EXISTING CEILING PANELS ALONG N ( THE CORRIDOR TO STAIRWAY RISER AS C) = 7 NECESSARY TO INSTALL NEW FIRE F- zN PROTECTION SYSTEM. SAVE PANELS FOR Q o N I I -(:4D I 'o I I I REINSTALLATION. ICI � ICI � ICI - - - I �, � "' J • ' II II II E T ' I I I I I I I I I � \ � � \ �' I �,' �•� I ( I EQ. EQ. I I I EQ. EQ. I ( I I I — S. EXISTING /� ROOF I I I I Ij I i i /• Ifs �`-� �� 3} I I I I ---- -- ----� V----- ------N Q '•. F'V ��r I I I I I I CONC. JOIST I I I I I DESIGN BELOW I I I NEW (TYP.) I I I I EXHAUST I DRAWN I I I I FAN (TYP.) I I CHECKED EXISTING I I I I I I I I PARAPET I I I I I I I i i SCALE AS NOTED I I ° III d I I i i i NOTE: ALL ITEMS SHOWN ON DEMOLITION CEILING PLAN ARE EXISTING DAB I I N I I I ; TO REMAIN UNLESS NOTED OTHERWISE. 8-4-98 I I PROJ. No. L---------------------------------------J 9736 SHEET No. EINDOSCOP ISOLATION RM. PLANS FAN PENETRATION PLAN � ISOLATION ROOM CEILING PLAN � ;)ISOLATION ROOM CEILING DEMO. PLAN N FF (5)EXHAUST SCALE: 1/2'=1'-O' ENDOSCOPY SCALE: 1/2 :1'-0' ENDOSCOPY A - 2 ENDOSCOPY OSCO