Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
00-0883-011
> 1 U ) ) ) ) ) ) oc cl 4 ENCLOSUREMOKE ) ) W O. ) ))) ca UJ uj LID ) ) ) ) ) Ln pu 2HR FIRE/SMOKE �- M = ENCLOSUR� 2HR C.D C G + "E v� a I� VESr. W OFFICE STAN a O ® B O O ° ♦~� Q L D O O O � o 0 0 0 <6> 1W-- -, 3 0 O CLASSROOM )n T Q STAFF B ° 2 Z v, LL 0 wanNC � TOILET ° O ° Q O O e MECHANICAL I _ M O I STORAGE Q ROOM vFA v li I PATIENT T p @ I � p I I I ° O CHILD O TILES O °M O O O Tgn£wfT ° CARE O .: ®I o JAN.o a.FUR ST B FlLEROOM DISTANCE 88 AN E T -88 FT. O Sp CORRISO PATIENT MEWING Li MEWING VENWG Q OFFCE Q 61 RECEPT, O O ROOM ROOM HOT LAB ui LIFE SAFETY CALCULATIONS O ° DISTANCE TO � p AN EXIT-74 FT. Q FIRST F L®® R Q MAMMOGRAPHY Q Z SD SD vFA ° q0 elo WORK ° Q 5,587 CORRIDOR 2 ° ° NI1 lIN AREA $.F. p ° ° fl) O NUCLEAR FLOUROSCOPY PATIENT TALENT CORRIDOR O FE MEDICINE Q SMOKE COMPARTMENT CALCULATIONS AR��� TOILET TOILET TOILET ° � Q o 0 O B o o ci SMALLEST ° ° o ° o TREADMILL p Q FE MOGRAPHY V' M S) n ADJACENT COMP'T i I 0 0 O PATIENT d ¢ w Ld 1 w n a M 00 N B EXAM ULTRASOUND A O Ni° O O LL ¢ [t a a N COMPARTMENT OCCUPANT ADJACENT N0. OF i i I O OFFICE O `s O B DRESS FLauROSCOPY _ < z AREA (S.F.) OCCUPANTS REFUGE COMP'T LOAD SMOKE OFFICE AREA EXAM ULTRASOUND sus-wanNC ° DRESS D� O sD ° Q d � � W FO SLEEPING NON-SLEEPING ASSEMBLY OFFICE MERCANTILE AREA SLEEPING NON-SLEEPING Q CORRIDOR Q ° SAL CLEAN J U 9 (120 S.F./P) (240 S.F./P) (15 S.F./P) (100 S.F./P) (30 S.F./P) (PERSONS) COMP'T COMP'T (30 S.F./P) (6 S.F./P) I I O O O O ° O B WFA DT" unL W o LU = S.F. 1 A ___-- 14,264 14,2x4 / 240 = 5s 1 B, 1 E, 1 G 1 G 8,400 / 6 = I I OFFICE 7,1x4 PATIENT ° O EQUIP w ¢ SD O Z O O PATIENT PATIENT $,F, - ® - Q 8,400 -___- COMPLIES I � TOILET TOILET sD O EQUIPMENT ROOM ® 1HR FIRE/ Z � �, � � 1,407 O O O Roots � Q I SMOKE WALL � ¢ o W W 15,216 / 6 DRESS O ® O O L+- c 1 B _____ 15,216 12,000 / 240 = 50 1 B, 1 C, 1 E 1 B 15,216 ----- 2 536 COMPLIES qq 10,217 / 240 = 43 1B, 1D, 1E, 1 E.1 3,212 3,212 / 6 COMPLIES 1C ----- 10,217 2,970 789 2,970 / 100 = 30 1.E1, IK IN """"" 535 � N 789 30 = 26 I 1 I OFFICE ® ° CORRIDOR O SD ❑ ® ULTRASOUND PATIENT O CT.ROOM 1D "-°' 13,850 13,850 / 100 = 139 1C 1C 13,796 ----- 13,796 / s = COMPLIES I i SMO FIRE/ u� O SOIL O DARK ra' T SUB-wanNC ° CONTROL ° O O 1E ----- 12,000 12,000 / 240 = 50 1A, 1B, 1F 1F 5,330 ----- 5,330 / 6 = COMPLIES 0 Q a 888 �O STORAGE 1 I ,212 3,212 / 15 = 214 1C 1C 13,796 ----- 13,796 / 6 = COMPLIES FUR�-sr ® Sp 42 sD 2,299 I I AN ANC- TO 1F ----- 5,330 5,330 / 240 = 22 1A, 1E 1E 12,000 _____ 12,000 / 6 = COMPLIES I I AN�XIT-106 FT. e � �42 p ° SD p O Q O ® Q SD � 61d SD O RRIB �D CORRIDOR I e� I--' 2,000 I I y PS � FE O FE O � [1+ 1G _____ 8,400 8,400 / 240 = 35 1A 1A 14,264 _____ 14,264 / 6 = COMPLIES EKG/ RECEPT. W N 2 377 I 1 I TREADMILL FURTHEST ad C'3 -1K ----- 7,774 7,774 / 240 = 32 1L, 1M, 1N 1L 5,587 ----- 5,587 / 6 = COMPLIES I I I O e ° OFFICE ca�NSUL� G ° sD 1 I� ° > o O A SMOKE DOOR-162 FT. a H 931 O O O O READING/ READING/ O O 1 CONSULTING CONSULTING O Q e FURTHEST A'r :R, W 1L _____ 5,587 5,587 / 240 = 23 1K, 1M 1M 7,194 _-_-_ 7,194 / 6 = COMPLIES I s.F. GE I Sp O sO sD Q 7,774 O DISTANCE TO m.-.2 W 1'199 O sD AN EXIT -182 FT. 1 M _ 1 K, 1 L, 1 N 1 L 5,587 5,587 / 6 = COMPLIES WAITING a PATIENT sue-warrNC O ° ----- 7,194 7,194 / 240 = 30 ""-"" 931 1 O O TOILET p O cq. ° F- 1N 5,908 5,908 / 240 = 25 1C, 1K 1M 1M 7,194 ___ 7,194 / 6 = COMPLIES I I %QL�N STORAGE �°, O sD Q sD O ®_ CORRIDOR .� DRESS Sq ----- -- 1,199 I Q PATENT coRPo B O c H TOILET A O O T ®O O O p O Q p COMPUTER I� C m ----- LJ ° PANTRY BLOOD WAITING IX JOAN. SOIL R L ROOM U t, 1 I I II Q RECEPT. O ° DRAW a Q W Z DOB ° 1 EXIT CALCULATIONS I I i I ®� ® ® Q °� Q Q TALENT O COMPARTMENT OCP. LOAD EXIT CAP. PROVIDED I I Ps OB o Q ° "'e m O O AREA (S.F.) (PERSONS) INCHES TOTAL EXIT e o � HOLDING O COMP'T CAP. PROVIDED I I I I I 1 N ° SLEEPING NON-SLEEPING ASSEMBLY OFFICE MERCANTILE (120/240) STAIRS LEVEL (PERSONS) I I I I �' ° ° Q Q ° (120 S.F./P) (240 S.F./P) (15 S.F./P) (100 S.F./P) (30 S.F./P) I I I I 5,9 8 0 ° Q NURSES Q MA E K I ---- 198 0.2 = 990 990 i i ° O STORA �® 1A ----- 14,264 14,264 / 240 = 59 - / WAITING $ Q I I I SD a O ° O 1B ----- 15,216 12,000 / 240 = 50 ----- 204 / 0.2 = 1 020 1020 I w I I I I 4 5D e O B O Q CDR Q ® 84 O NURSE SCHEDULING B VFA STATION FILM EQUIPMENT 10,217 / 240 = 43 I a I I I Q ® O OFFICE 1 C ----- 10,217 2,970 789 2.970 / 100 = 30 ----- 348 / 0.2 = 1740 1740 1 I I I I O SCE wFA Ps O 789 30 = 26 sD ;" PROCESSOR ROOM 2HR FIRE/SMOKE 13,850 100 = 139 1270 I CANOPY DRIVE WAY 1 ENCLOSURE O O O O O O � O 1D _____ 13,850 / _____ 254 / 0.2 = 1270 I I I 1 0 0 0 STAFF STAFF EIEC 12,000 / 240 = 50 ---_ 126 0.2 = 630 630 I I I I 1 E ----- 15,862 - / - I 1 I 1 ROOM WORK/FlLE ° CORR OR PANTRY LOUNGE ELECTRICAL ROOM _____ 3,212 15 = 214 108 0.2 = 540 540 2HR FIRE( SMOKE MALL I k MECHANICAL 1E.1 3,212 / / ---7-1 / Q p FF ° TOILET Roots ROOM OFFICE OFFICE I Q _ r TRANSFORMER O 5.330 / 240 = 22 - 1 ARCADE PS p� LOCKER ° E: ° Q PUMP PUMP 1 F ----- 5,330 ----- 252 / 0.2 - 12x0 1260 ARCADE ❑ 1G ----- 8,400 8,400 / 240 = 35 ---__ 102 / 0.2 = 510 510 I SD 4 SO SD STAFF ENTRANCE ENTRANCE 4 CORRIDOR ° m �� Q 1 K 7,774 7,774 / 240 = 32 ----- 42 / 0.2 = 210 210 ---- _--- ---- ---- O O ----- - 1L ----- 5,587 5,587 240 = 23 ----- 84 / 0.2 = 420 420 44 %2HR FIRE/ 1 I I O O O O I R FIRE SMOKE 2HR FIRE SMOKE 2HR FIRE SMOKE " 1 M ----- 7,194 7,194 / 240 = 30 ----- 84 / 0.2 = 420 420 I I I VESTIBULE I srew s SMOKE WALL / / // ENCLOSURE ENCLOSURE ENCLOSURE 1N 840 1 INFORMATION DESK VESTIB ___-_ 5,908 5,908 / 240 = 25 ----- 168 / 0.2 = 840 1 GaROEN I GARD°J Q z O TOTAL EXIT CAPACITY (PERSONS) 791 IS LESS THAN 9850 W S M H - PARTIAL FIRST FLOOR w J z LIFE SAFETY PLAN = SCALE: 1/16' = V-0" ® Q (n ~ 0 cv) w p , ® � _ U) Z z 00 „ � O SYMBOL LEGEND �" Q ONE HOUR RATED WALL OR PARTITION ('3ENERAL LIFE SAFETY / CODEE SUPPORT INFORMATION 0 O TWO HOUR RATED WALL OR PARTITION 0 0 Aft O O N � THREE HOUR RATED WALL OR PARTITION N FOUR HOUR RATED WALL OR PARTITION EXIT LIGHT HOSPITAL PROTECTION REQUIREMENTS EXIT CAPACITY-STAIRS NOTE: SHADED AREA INDICATES PPLI ABLE CODES o LIGHTED FACE LIFE SAFETY FACTORS APPLICABLE AND BUILDING CODE CLASSIFICATIONS IL EXIT LIGHT (DIRECTIONAL) LIFE SAFETY CODE LIFE SAFETY CODE INSIDE ACCESS EXIT v NOTE: SHADED AREA INDICATES GENERAL NFPA 101, 1994 NFPA 101, 1994 WIDTH CLASS TO ROOF CAPACITY � LIGHTED FACE (MAIN / PAVILION BLDG.) (NORTH TOWER) (INCHES) (INCHES) o w LL FE FIRE EXTINGUISHER PROJECT HAS BEEN DESIGNED AND SHALL BE INSPECTED FOLLOWING OCCUPANCY CLASSIFICATION EXISTING HEALTH CARE NEW HEALTH CARE STAIR 1 44 A 44 / 0.3 = 147 j `n 120 S.F. / PERSON - PERSON - HEALTH THE BUILDING CODES CURRENT EDITIONS, UNLESS OTHERWISE SPECIFIED. w w FIRE JACK CARE SLEEPING TYPE OF CONSTRUCTION TYPE I (332) TYPE 1 (332) STAIR 2 44 A 44 / 0.3 = 147 I F OCCUPANT LOAD 240 S.F. / PERSON - HEALTH CARE * � Z m FHC FIRE HOSE CABINET CHAPTER 59A-3, FLORIDA ADMINISTRATIVE CODE HOSPITAL FIRE SPRINKLERS (INTERIM PROTECTED) YES YES STAIR 3 44 A 44 / 0.3 = 147 Q W TREATMENT LICENSURE, JULY 1997 EDITION o � FL FIRE LIGHT MAX. TRAVEL DISTANCE TO EXIT 150 FT. 200 FT. STAIR 4 44 A YES @ LEVEL 4 44 / 0.3 = 147 , FIRE INDICATOR LIGHT •• F CAPACITY OF MEANS OF EGRESS * NFPA 101 LIFE SAFETY CODE, 1994 EDITION �•�' ,�� ❑ CEILING MOUNTED - CHAPTER 13: EXISTING HEALTH CARE OCCUPANCIES MAX. DEAD-END CORRIDOR NO REQUIREMENT 30 FT. STAIR 5 44 A YES © LEVEL 4 44 / 0.3 = 147 ,�,_.,o L �` A FIRE ALARM SPEAKER • S * - ADE COUNTY 2 HRS. 2 HRS. STAIR 6 44 A 44 / 0.3 = 147 . OF SOUTH FLORIDA BUILDING CODE (SFPA) MIAMI D FLOOR/CEILING CONSTRUCTION _� LIFE SAFETY CODE _ o H FIRE-HORN 1994 REVISED EDITION - 1-1 2 HRS. 1-1 2 HRS. STAIR 7 44 A YES @ LEVEL 8 44 / 0.3 - 147 r^:�'' , •`� SPRINKLERED NON-SPRINKLERED * ROOF/CEILING CONSTRUCTION / / FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION ���~'� 7 3 STAIR 8 44 A YES Ca? LEVEL 2 44 / 0.3 = 147 �., ':. ".`• B FIRE ALARM BELL STAIR 0.3 IN. 0.6 IN. OCTOBER 1997 EDITION BUILDING HEIGHT-STORIES w='... c {' ,• VFA VISUAL FIRE ALARM LEVEL TRAVEL 0.2 IN. 0.5 IN. STAIR 9 44 A YES C�? LEVEL 2 44 / 0.3 = 147 DESIGN . THERMOSTAT STAIR 10 44 A 44 / 0.3 = 147 DRAWN SD SMOKE DETECTOR TOTAL NUMBER 30 S.F. / PERSON - PERSON - HEALTH STAIR 11 44 A 44 / 0.3 = 147 CHECKED HD HEAT DETECTOR OF OCCUPANTS CARE SLEEPING SCALE IN SMALLEST AS NOTED HALON FIRE SUPPRESSION HEAD ADJACENT 6 S.F. / PERSON - HEALTH CARE DATE H COMPARTMENT TREATMENT 1-5-99 PROJ. No. FIRE SPRINKLER HEAD 9736 SHEET No. <9> EXIT CAPACITY IN INCHES PART.' �St F LIFE SAFET LAN CD AIIIIIIN L S - 101