00-0883-007 I J ) 1 1 ) 1 ) ) FIRE PROTECT �ON NOTES : 1 . APPLICABLE CODES AND CRIT W CD A. NFPA 13, "STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS". z w � cn 1 B. NFPA 101 , " LIFE SAFETY CODE". + co co z a o C. CHAPTER 4A-3 F.A.C. STATE OR FLORIDA FIRE PREVENTION CODE. Y 0 0) 1 1/4 w _j (0 � LJ a D. SOUTH FLORIDA BUILDING CODE - DADE EDITION. H a LL co UP TO EXIST. 6"x2 1/2"x2 1/2" R.M.V.- — — E. ALL OTHER APPLICABLE LOCAL CODES, ORDINANCES AND THE INSURANCE z z a 1 » u UNDERWRITTERS (FM) REQUIREMENTS. ^ cp NEW INSPECTORS 2. PROJECT REQUIREMENTS: TEST, SIGHT A. A COMPLETE FIRE SPRINKLER SYSTEM SHALL BE INSTALLED TO PROVIDE GLASS & DRAIN. ® A 100% FULL COVERAGE OF THE AREA WITHIN SCOPE OF THIS PROJECT, AND SHALL BE COMPATIBLE WITH THE FLOOR LAYOUT, CEILING NEW 3" D o O TYPE AND ARRANGEMENT. THE WORK INDICATED HEREIN PROVIDES THE MINIMUM O O FL. SW. / WORK NECESSARY TO COMPLETELY FIRE SPRINKLER THE INDICATED NEW 3" I.V. — 2" � ISOLATION ROOMS. THIS INCLUDES, BUT IS NOT LIMITED T0, RISERS, DRAINS, J W/ T3" VALVING, PIPING, FITTINGS, SUPPORTS, TESTS AND HEADS. CAPPED CONNECTIONS g C�0 HAVE BEEN INDICATED TO REFLECT EXTENSION WORK TO BE PROVIDED y 1_7 F7 s EXIST. 6"F.STP. UNDER A FUTURE FIRE SPRINKLER PROTECTION CONSTRUCTION CONTRACT. (SUPPLIED FROM EXISTING 750 GPM FIRE PUMP LOCATED B. NEW CEILING MOUNTED SPRINKLER HEADS SHALL BE FULLY RECESSED, WITH o ON GROUND FLOOR LEVEL IN - Z WHITE COVER PLATEco uj M W U EAST WING OF THIS BUILDING.) 1 » C. LOCATE SPRINKLER HEADS OF TYPE SPECIFIED TO OBTAIN PROPER a W < N n COVERAGE. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLANS. ~ N Lu c co 3" 3„ & C F.SP.L. SPRINKLER HEAD LAYOUT SHALL BE SYMMETRICAL. WHERE uj TFNSInN INSTALLED IN ACOUSTICAL CEILINGS, HEADS SHALL BE PLACED IN a o 2"DRAIN RISER DOWN. I PHA E VIII OF CONSTRUCTION TERMINATE AT 6" ABOVE 3" CENTER OF CEILING TILES, UNLESS NOTED OTHERWISE = W W W o f J GRADE. 2" CAPPED D. THE SYSTEM SHALL INCLUDE ALL MATERIALS, ACCESSORIES AND o m FOR FUTURE EQUIPMENT NECESSARY TO PROVIDE A SYSTEM COMPLETE AND READY :F EXTENSION FOR USE. THE SYSTEM SHALL BE INSTALLED TO AFFORD COMPLETE COVERAGE AND BE FREE FROM OPERATING AND MAINTENANCE DIFFICULTIES, ALL IN ACCORDANCE WITH DESIGN DOCUMENTS. co w LO E. DEVICES AND EQUIPMENT SHALL BE OF A MAKE AND TYPE LISTED 0 co BY UN DERWRITERS LABORATORIES AND APPROVED BY INDUSTRIAL RISK cco INSURERS. IN EACH OF THE NFPA STANDARDS REFERRED TO HEREIN, o m THE ADVISORY PROVISIONS SHALL BE CONSIDERED TO BE MANDATORY. w a H F O S T T E F. SPRINKLERS SHALL COVER THE ENTIRE AREA OF THE ROOMS) T � L S � � V N INCLUDING ALCOVES. SPRAY SHALL NOT BE BLOCKED BY WALLS OR w �� w FIRE SPRINKLER PROTECTION PL N PARTITIONS. U3 SCALE 1/4"=1 '-0" G. SYSTEMS SHALL HAVE FLUSHING CONNECTIONS. w H. PROVIDE AND MAINTAIN A MINIMUM OF 18" CLEARANCE BETWEEN THE '-� � � ° c BOTTOM OF THE SPRINKLER DEFLECTOR AND THE TOP OF THE O STORAGE, FILE SHELVING, ETC. I. CUT, PATCH, SLEEVE & SEAL EXISTING WALLS IN CEILING SPACE ABOVE AT NEW PIPE PENETRATIONS. J. SEE ARCHITECTURAL PLANS) FOR LIMIT OF WORK IN EXISTING CEILING. F I E P O T E C T I O N L E G E N D K. SEE ARCHITECTURAL PLANS) FOR UL LISTED DETAILS OF FLOOR AND SYMBOL ASSREV. DESCRIPTION WALL PENETRATIONS. 3/8" ROD COUPLING — — — EXIST. EXIST. PIPE TO REMAIN. 3. SPECIFICATIONS: 3/8" ALL THREAD ROD A. PIPING. F.SP.L. NEW FIRE SPRINKLER LINE PIPE RING . o F.STP. FIRE STANDPIPE 1) SIZES 1" TO 2" TO BE "XL" PIPING OR EQUAL. QUICK RESPONSE FIRE SPRINKLER HEAD FULLY 2) SIZES 2-1/2" AND LARGER TO BE SCHEDULE 10 BLACK STEEL. RECESSED W/ WHITE COVER PLATE. 3) MINIMUM SIZE FOR PIPING AND TEES TO BE 1 ". v - QUICK RESPONSE SIDE WALL SPRINKLER HEAD B. SPRINKLER HEADS. � � �p p�� O FL.SW. FLOW SWITCH VII�V ��I ®� T L 1) FINISHED CEILING MOUNTED - NEW 1/2" 1557. VIKING HORIZON MIRAGE co N.T.S. �a I.V. INDICATING VALVE HIGH PRESSURE QUICK RESPONSE CONCEALED SPRINKLER WITH �' CEILING MOUNTED COVER PLATE. M a T.SW. TAMPER SWITCH 2) SIDEWALL MOUNTED - NEW 1/2" 1557. VIKING BRASS SIDEWALL ® U R.M.V. ROOF MANIFOLD VALVE. QUICK RESPONSE HEAD. �r • NEW TIE-IN TO EXISTING PIPE. 3) ALL NEW HEADS TO BE CENTERLINE OF CEILING TILE IF EXISTING z ® CONDITIONS ALLOW. 4 SPARE HEAD CABINET & WRENCH AS PER N.F.P.A. #13. w ® � C. HANGERS. Z CIO 0 1 ALL HANGERS TO BE AS PER N.F.P.A. #13. -0 INDICATING TYPE FLOOR CONTROL ) VALVE W SUPERVISORY SWITCH, / 2) ALL ARM-OVERS, OVER 24 IN LENGTH TO HAVE A HANGER. SEE PLANS FOR SIZES. D. FLOW & TAMPER SWITCHES. cn ° WATERFLOW SWITCH ® 0 1) ALL FLOW & TAMPER SWITCHES TO BE SINGLE POLE, DOUBLE THROW. N ° cc HANGER ROD TO STRUCTURE FEED MAIN, SEE PLANS cn FOR SIZES. o � z � o = d cn U NIPPLE 4" MAXIMUM LENGTH SPRINKLER BRANCH v w CIO z STANDPIPE RISER Q ° 1 " INSPECTOR'S TEST VALVE TO SPRINKLER SYSTEM <H w � cV 0 1 " AUXILIARY ,"'- o z DRAIN VALVE Q 4 °• 1 " DROP NIPPLE o 0 1" SIGHT GLASS LOCATION OF EXISTING rsw, b " 1 2DUCER FIRE PUMP ON GROUND 1 x " RE CONCEALED TYPE / SPRINKLER HEAD FLOOR LEVEL 2" DRAIN RISER. 3 SEE PLANS FOR 1" UNION W/ BRASS ORIFICE DISK W/ HOLE EQUAL TO DIS- LOCATION OF WORK LOCATION. CHARGE FROM THE SMALLEST ON SIXTH FLOOR cn W+s• SPRINKLER ORIFICE IN THAT FLOOR. LEVEL FOR THIS DESIGN PROJECT. T.C.R. CEILING COVER PLATE FINISHED CEILING DRAWN A.R. IN WHITE FINISH EAST TOWER CHECKED BUILDING o.A. SCALE AS SHOWN DATE 08-04-98 PROJ. No. FLOOR L V L VE I T H N SHEET o. SPRINKLER ARM OVER DET ML IN P CT ® R'S TEST C ® NNECTI ® N KEY PLAN - EAST TOWER N.T.S. N.T.S. N.T.S. P FIRE PROTECTION PLAN, NOTES, LEGEND AND DETAILS �� e