Loading...
00-0883-006 C3 cn Z Y ) ) ) w co w f- Z W IA J W t_A m N co cn W L' o 0 Al Lu Lo J LL (C Q co ix NEW FAN (SCU BLOWER a M a O 3.9 AMPS @ 120 VOLT N co NOTE: EXISTING CEILING IS LAY-IN NOTE: SCU TILE TO BE REMOVED AND REPLACED SEE ARCHITECTURAL DRAWING WITH A NEW DRYWALL CEILING. SEE FOR NEW DOOR LAYOUT. ELECTRICAL NOTE #27 ON SHEET E-1 . Lu NEW CIRCUIT RR-34 MON SPARE 1 P. 20 A. BREAKER) J X12 & 1 #12 GRID. IN 1/2 C. o ci F J N MOUNT ABOVE' NEW � DOOR TO ROM. J w N U. H M Q n ,., N Z E V W Lp cc SCU w SE J a ~LU W a MON ANTI-ROOM Z w Z NEW CIRCUIT CL2NB-35 ��`� o J M T J F M12 ARE 1 P. 20 A. BREAKER) N o m & 1 #12 GRID. IN 1/2 C. W �o NEW FAN (SCU BLOWER) �; N 3.9 AMPS @ 120 VOLTS I- w ul Cw. °o >_ ri m F- �-r Q J i W PARTIAL 2nd FLOOR PARTIAL 2nd FLOOR NORTH RECOVERY ROOM ELECTRICAL PLAN w P N °a � �o TOWER ICU ELECTRICAL PLAN SCALE: 1 /4" m 0. p er :. SCALE: 1 /4" = l '—O" ►�'�-. 0to �0 3 O ELECTRICAL SYMBOL LEGEND TYPICAL NOTE: TWO(2) EXISTING 1 "x4" FLUORESCENT FIXTURES THIS ROOM, _ SURFACE MT'D, TO REMAIN-SEVARCH. DWG'S FO NECESSARY DIREC Ilf ONS I I CONCERNING REWORK THIS PR JECT. M PREWIRED BLOWER MOTOR INSIDE "SCU" OR NEW FEAU FAN FILTER UNIT. TOGGLE TYPE DISCONNECT SWITCH LOCATED ABOVE LAY-IN CEILING. �� NEW FEAU-1 ?lF MOUNTED IN JUNCTION BOX WITH COMMERCIAL COVER ATTACHED NEW FAN MPS, 120V, 10 TO 1/2" KNOCKOUT AT TOP OF "SCU" FURNISHED BY MANUFACTURER. (S.C.U. BLOWER) (AB . CLG.) 3.9AMPS JUNCTION BOX WITH TOGGLE TYPE DISCONNECT SWITCH LOCATED ABOVE LAY-IN CEILING. 120 VOLTS u INTERLOCK W/RM. AIR PURIFICATION UNIT (CKT. E6-9) 2 T II M MOTOR RATED SWITCH CID w M M p EQUIPMENT JUNCTION BOX MOUNTED INSIDE EQUIPMENT . ® � I- PM NEW - SEE LEGEND m 2 . TYPICAL SCU J E6-9 (2 #12 & 1 #12 GND. IN 1/ 2 'C.) o o MON ELECTRONIC MONITOR (NEGATIVE PRESSURE) WITH AUDIBLE ALARM AND DIGITAL O O ROOM PRESSURE READOUT. SURFACE MOUNT TO WALL AT 48 TO CENTERLINE OF DEVICE AND CONNECTED AS DIRECTED BY THE MED AIR CO. FURNISHED < w � LOCATIO OF EXISTING ITH SCU . ® � F.C.U. BV. TO REMAIN C> CC z NEW CKT. E6-9 ( ) T 24 VOLT CONTROL TRANSFORMER FURNISHED PREWIRED IN "SCU". co (SPARE RKR) 2 �120A. �°•�°�°���� El & 1#12 GND. M IN 1/ SE THROUGH WALL PRESSURE SENSOR MODULE. MOUNTED ABOVE CENTER (� 2"C. LINE OF DOORWAY AND CONNECTED AS DIRECTED BY THE "MED AIR CO. O SEE ELECTRICAL NOTES. FURNISHED WITH "SCU". D C6 TYPICAL 24 V. UABLE. e 24V. ® 0 V �/ ' � 24 VOLT WIRING/CABLE RUN IN CO."WALLS AND ABOVE CEILING. CONNECTIONS AS N DIRECTED BY THE MED AIR SEE ELECTRICAL NOTES FOR ADDITIONAL INFO. to FURNISHED WITH "SCU". z z cn III y r— O Oz FLEXIBLE METAL CONDUIT AND WIRING. _ � U U Qw C CONTROL WIRING IN CONDUIT. o U o w C�3 woO lc�o �- oo Z nn a O� 1 0 j ii 'rrr. DESIGN NOTE: DRAWN E.M. IT� - - � �- - - -� I- - —I LL BE UNDERSTOOD THAT ALL ELECTRICAL WORK . CHECKED M.S.F. IN ALL THE ROOM'S IN THIS PROJECT SHALL. BE COORDINATED WHITH THE MECHANICAL AND ARCHITECTURAL DWG'S BY THE CONTRACTOR. SCALE AS SHOWN IF ANY QUESTIONS ARISE AN R.F.I. SHALL BE ROUTED THROUGH THE DATE PROPER CHANNELS. 08-04-98 PROJ. No. 9753 SHEET No. PARTIAL 6th FLOOR EAST TOWER ENDOSCOPY ELECTRICAL PLAN N SCALE: 1 /4" = V-0" E - 6___Jlv