Loading...
00-0273-037 �I 'Jill 4 1 _ .' . . . . . . . . . . . . . . . . . LAY LAVATORY, AMERICAN STANDARD 3003.605 VANETTE COUNTER TOP. FAUCET 2352.431 PLUMBING SHEET INDEX ' ZURN Z-1022 REGENCY CENTERSET WITH CROSS HANDLES. Howard 3noweisa AUTOMATIC 6A Design Group PRIMER HANDICAP LAVATORY, AMERICAN STANDARD, DECLYN WALL HUNG LAVATORY MODEL PO.1 PLUMBING NOTES 4200 Aurora str«t i HLAV #0321.075. WHITE, WITH FAUCET AMERICAN STANDARD MODEL #2000.101. CONTRACTOR ` Florida da 39th FLOW FRO TO SUPPLY CONCEALED ARM SUPPORT CARRIER FOR MOUNTING OF LAVATORY. SUPPLY Q , FLOW t0 P2.1 SANITARY PLAN ; 304-481- 131 ; WATER FIXTURE TRUBRO MODEL #1020 HANOI LAY-GUARD INSULATION KIT. MUST MEET A.D.A. CODE. Q RISER - WATER CLOSET - FLUSH VALVE, " P3.1 DOMESTIC WATER PLAN BOWL FLOOR MOUTEO SIPHON JET ACTION VITREOUS � • CHINA, ELONGATED RIM AND 1-1/2 TOP SPUD, AMERICAN STANDARD 2234.015 MADERA i WC AQUAMETER, 1.5 GPF TOILET WITH A SLOAN x{111 FLUSH VALVE NO A CHURCH #9500C P5.1 SANITARY ISOMETRIC Q � ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' � FLOOR DRAIN OPEN FRONT SEAT LESS COVER. Q AIR GAP VACUUM J.R. SMITH P6.1 DOMESTIC WATER, dt PROPANE GAS ISOMETRIC . . . . . . . . . . . . . . . . . 0 BREAKER POINTS 2005-AP HANDICAPPED WATER CLOSET - FLUSH VALVE, BOWL; FLOOR MOUNTED, SIPHON JET, VITREOUS CHINA WITH ELONGATED RIM AND A 1-1/2" TOP SPUD AND 18" HIGH AMERICAN : r d , i HWC STANDARD 3043.102 ELDERLY NEW CADET AQUAMETER, 1.5 GPF TOILET WITH A SLOAN ; 12" MINIMUM . X1111 FLUSH VALVE AND A CHURCH #9500C OPEN FRONT SEAT LESS COVER. ; TO HORIZONTAL RUN IN PIPE ' ' UR URINAL AMERICAN STANDARD, WASHBROOK 6501.010, FLUSH VALVE SLOAN ROYAL 188-1 �, WALL MOUNTED, WHITE URINAL. WALL CARRIER ZURN. PLUMBING NOTES • SHOWER, MIXING VALVE HOT AND COLD WATER, SHOWER MIXING VALVE SHALL BE A ' HSH SYMMONS TEMPTROL 2000 MODEL X25-500-X 830-SR ANT1-SCALD BALANCED PRESSURE SHOWER VALVE TO INCLUDE A 2.5 GPM FLOW RESTRICTOR AND INTERGRAL SERVICE STOPS. 1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE I' LOCAL CODES, , RULES AND ORDINANCES. . 2. PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE , FO FLOOR DRAIN, 3" PVC WITH 4" DEEP SEAL TRAP. HIMSELF WITH ALL EXISTING CONDITIONS. 3. ALL MATERIALS SHALL BE NEW. SINGLE STAINLESS STEEL SINK 25X22 DAYTON MODEL #K-12522 WITH CHICAGO 4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST ' SK FAUCETS MODEL �1786E3-CP KITCHEN 5-3/4 SPREAD GOOSENECK WITH 4 WRIST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. ALL I TRAP PRIMER EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE ; 4» BLADE FAUCET HANDLES. A PART OF THIS CONTRACT. 1, CONNECTION , k; GO, F000 WASTE DISPOSAL "!SE", "GRAINGER" STOCK �i5H504, 1/2 NP, 115V. 5. REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 6. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTION AND PEDICURE TESTS, PLUMBING CONTRACTOR TO OBTAIN PERMIT AND APPROVED SUBMITTALS PRIOR TO SK PEDICURE SINK BY OWNER/ARCHITECT. BEGINNING WORK OR ORDERING EQUIPMENT. PLUMBING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS OF HIS WORK BY REGULATORY AUTHORITIES. 3 . I HAIR 7• DRAWINGS I NUIPMENT,GETCMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, TRAP PRIMER DETAIL WASH HAIR WASH LAV. SINK BY OWNER/ARCHITECT. NOT ro scats LAY 8. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH ; THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ENGINEER/ARCHITECT ; FLOOR SINK: ZURN Z1900-10 WITH 4" DEEP SEAL PRIOR TO BEGINNING CONSTRUCTION. : I FS TRAP. FOR DIRECT WASTE USE GRATE 2 OR 3 9. VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERTS OF ALL EXISTING UTILITIES p GUY GRAY SPACE OPTIMAL AS REQUIRED. PRIOR TO BEGINNING OF CONSTRUCTION. ADVISE ENGINEER OF ANY DISCREPANCIES. , 10. WATER DISTRIBUTION PIPING ABOVE GROUND SHALL BE TYPE "L" COPPER. WATER DISTRIBUTION SAVER W/ 4 DEEP BOX FOR HAIR PIPING BELOW GROUND IN D.AaE AND BROWARD. COUNTIES SHALL BE TYPE "L" COPPER ALL HAIR INTERCEPTOR P-TRAP: ZURN Z1176-YR-1-1/2" » » V ; METAL STUD WALL INTER- OTHER COUNTIES SHALL BE TYPE M COPPER. p pRAp 11• PVC MAY NOT BE USED THRU RATED IASSEMBLIES OR IN PLENUMS. R PVC, WHERE CODE ALLOWS. (�) 12. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS AND APPROPRIATELY ��(- j H.W. HOT WATER RECIRC. PUMP: TACO MODEL 007 MARKED ACCESS PANELS. COORDINATE LOCATIONS WITH GENERAL CONTRACTOR PRIOR ' ARMTROL MODEL 500 RECIRC. BRONZE CASTING, 3/4", WITH "00" TIMER AQUASTAT, 115V, 1PH, 16 AMPS. TO INSTALLATION. WATER HAMMER ARRESTOR. PUMP 13. APPROVED SHOCK ARRESTORS ON MAIN LINES OR RISERS H PLUMBING FIXTURE AND , 14. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS. : PLUM'IN (�I in �C��{lE®ULC HW & CW HOSE CONNECTIONS 15. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD. f W/ VACUUM BREAKERS 16. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM ; d (WATTS OR EQUAL). NOTE: FIRE, SMOKE AND WATER PENETRATION BY FILLING VOIDS BETWEEN PIPE AND WALL/FLOOR FIXTURES UNIT AS SHOWN OR EQUAL. SLEEVES WITH FIRE RATED FOAM, TO ACHIEVE THE SAME RATING AS WALLS OR FLOORS�'2� - ALL FIXTURES SHALL COMPLY WITH TABLE 46R-2 OF S.F,B.C. AS PART OF THE PLUMBER'S WORK. � ; 17. PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM O 1 2 HW do CW DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE BY ' I� PING OWNER. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION �(1 WASTE. WHICH MAY HAVE BEEN DAMAGED. 1 VACUUM RECIRCULATION 18. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES ANO ALL WATER HAMMER { 1 FINISHED FLOOR S RELIEF VALVE PUMP ARRESTERS. ACCESS PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING AND s AQUASTAT AND MUST MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED. y ; COLD WATER SUPPLY TIME CLOCK 19. PROVIDE CHROME PLATED COMBINATION COVER PLATE AND CLEANOUT PLUG OR ACCESS _ TO WATER HEATER. CHEC ' HEAT TRAP VALVE PANEL FOR ALL WALL CLEANOUTS. 20. NO COMBUSTIBLE MATERIAL TO BE USED IN MECHANICAL ROOMS OR IN CEILING SPACES 0 • WHERE USED AS RETURN AIR PLENUMS. N U U�J F UU A� (l -11 O U V� M A�H�U V L� �O U V U V E� � HOT WATER TO FIXTURES � �" �- "' 21. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL OR ELEVATOR NOT TO SCALE AS SHOWN ON PLANS EQUIPMENT ROOMS. PROVIDE A 210'F RECIRCULATION LINE 22• ALL CONTROL VALVES SHALL BE TAGGED AND MARKED. A REPRODUCIBLE DIAGRAM , PROVIDE FULL PORT BALL TEMPERATURE AND LOCATING ALL VALVES SHALL BE PROVIDED FOR OWNER/OPERATOR." SHUT-OFF NAIVES 23. ALL CONDENSATE DRAIN PIPING SHALL BE TYPE L COPPER WITH 1 THICK 150 PSI PRESSURE ARMAFLEX INSULATION WHERE USED IN A RETURN AIR PLENUM. PVC PIPING WITH 1" THICK ; PROVIDE PIPE RELIEF VALVE ARMAFLEX INSULATION MAY BE USED IN LOCATIONS WHERE ALLOWED BY LOCAL CODES. WITH TEST LEVER 9Y 6A9 GOMF'ANf(V�21FY) BY PLUMDIN9 GONTW GTOR UNIONS, DIELECTRIC SEE PLUMBING DRAWINGS FOR SIZE AND LOCATION OF PIPING. , � SIZED WITH AGA/CGA . 1� PPf6%*kE TEST GOGK BuILDiN9 4 IF REQUIRED FOR TEMPERATURE STEAM 24. PROVIDE ANGLE STOPS ON ALL WATER SERVICE LINES TO FIXTURES FOR INDIVIDUAL ; OAS PIPE UP Irmo eLDe. DISSIMILAR METALS. RATING 10%j OVER SHUT-OFF. OAS C" McTr=R or cFF1 Nne As SOWN ON�. HEATER INPUT. ' GAPAUTf�0N'y use 8tJ1GK 9TH..PIPC. THERMOSTAT AND 25. WATER PIPING INSULATION SHALL BE 1" THICK ARMAFLEX INSTALLED IN ACCORDANCE , I1 ON Pt.M1s PRESSURE REGU- PROVIDE A HARD WITH MANUFACTURERS INSTRUCTIONS FOR ALL HOT WATER PIPING. WHERE DOMESTIC I 1 PIPS INGRLA515L LATOR FURNISHED COPPER RELIEF WATER TEMPERATURES CAN CAUSE SWEATING ALL COLD WATER PIPING SHALL BE i 1 DIRT I."AT BOTTOM TH WATER HEATER. VALVE DISCHARGE INSULATED WITH 1/2" THICK ARMAFLEX INSULATION. Y a' LINE FULL SIZE OF 26. STUDOR MINI/MAXI AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO RJOM To Wr1J.. VENT PIPING THRU ROOF WHERE ACCEPTABLE BY THE PLUMBING OFFICIAL AND LOCAL ; ;, 6RAOe oat FLOOR RUN TO EXTERIOR CODES. INSTALLATION SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS. , i PAVEMENT l� U OF BUILDING AT 6" PR1:55URB RF6ULJ�TOR TO Rl Dt1G@ PRESr�URE TO 70 WG. ABOVE GRADE ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' GEN. REV. s vAEVE PLUMBING LEGEND : 3/30/00 f DRAIN VALVE BY 1 HEATER MANUFACT. YMPY P0WIRETANT3 FOR r INO AND PIPING WITH 0"COMPANY. CONTRACTOR SHALL PAY ALL OAS t:OhPMIY FEES FOR INSTALLATION. 1159 WELDED OR 5ePZV O PIPE AND FITTIN60 Phi PL"N9`�• CO CLEAN OUT �---5 SANITARY SEWER PIPING ' i • ' ��� ����I�� ®ETA�L. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT S.O.V. SHUT-OFf VALVE S- - - - -S VENT PIPING FIELD CONDITIONS. REFER TO ISOMETRIC RISER FOR PIPE SIZES. ;I NTS SET HEATER THERMOSTAT AT 120' F. COTC CLEAN OUT TO GRADE �---S DOMESTIC COLD WATER PIPING WATER HEATER TO BE 119 GALLON, ELECTRIC, 240 V. 3PH, 54KW, FD FLOOR DRAIN �------S HOT WATER PIPING (110') , , , , , , , , , , , , , , , , , t 0. A. SMITH CONSERVATIONIST "ASME" James Patrick O'Sha hnessy s. MODEL DRE-120-54 CW DOMESTIC COLD WATER Tr------S HOT WATER PIPING (140') +, List. AR 0011651 ; State of Florida Arc 'test HW DOMESTIC HOT WATER �--•CO-S CONDENSATE PIPING :State of Florida interior Designer: ,t HWR DOMESTIC HOT WATER RETURN S•-CA-•S COMPRESSED AIR PIPING Use. I.D. 0000348 , WATEn HECTOR SCHEDULEMETAOL Howard Snro sa ; H8 HOSE BIBS �-T&P-S TEMPERATURE AND PRESSURE RELIEF Design Group s NTS : 4800 Aurora Street VTR VENT THRU ROOF $---SO STORM DRAIN PIPING Florida 3si4e F� ; 306-481-9191 x' �Q GATE VALVE S-G-S GAS PIPING pOQ GLOBE VALVE �O�-S PIPE RISE OR DROP � ' ' ' ' ' ' ' ' ' ' ' ' � ' ' ' ' � �j CHECK VALVE 5-7-5 PIPE RISER UP �Q BALANCING VALVE �- CAPPED END OF PIPE "siaio.c. . . . 'i GAS COCK POINT OF CONNECTION : • • • • n�xre • • • • ; N WATER HAMMER ARRESTER (PDI-A ETC.) -�,� P-TRAP ' . . Prime Professional FD FLOOR DRAIN ap ' N `s 0 r df i r KAMM CONSULTING PROJECT ii: 2000-093 . . . . . . . . . . . . . . . . . . PROJECT MANAGER: BRAD BROWN 02-28-00 . . . .DATi . . . . ; N 947 Clint Moore Rd Boc Ratbi FL,334p ; { englnuibng�kabmmax�Si 991b23 t - r Onsu 1C.4 t � ,�� PO - 1 Lon T.Carter Florida License #35249 d 4 Mircea Pella Florida License¥48798 p A•��+ " rY ' . . . . x �'t• ••' 4;10 .• ��' � � .,. N loT"�t11� § y I O U I