ARCHITECTURAL ABBREVIATIONS ARCHITECTURAL SYMBOLS cARIos
FAG[ ER
RC
H ITECT
i
i
i
BLDG. CORE WALL &/OR EXISTING CONSTRUCTION
AB ANCHOR BOLT IN INCH 1. THE WORK SHOWN ON THESE PLANS, (ALSO REFERRED TO AS CONTRACT DOCUMENTS), AND HEREIN SPECIFIED IS
ABV ABOVE INCL INCLUDE �, . INTENDED TO INCLUDE ALL LABOR AND MATERIALS NECESSARY TO COMPLETE THE PROJECT IN ITS ENTIRETY, WHETHER
A/C AIR CONDITIONING INS INSULATE(D D)(LNG ING) BASE BUILDING COLUMN SHOWN, DESCRIBED, REASONABLY IMPLIED, REQUIRED, OR INFERRED.
ACOUS ACOUSTICAL INT INTERIOR 2. THE CONTRACTOR SHALL VISIT AND INSPECT THE SITE TO FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS PRIOR
ACT ACOUSTICAL TILE TO BID. ANY CONFLICTS OR DISCREPANCIES BETWEEN OBSERVED EXISTING CONDITIONS AND THE PLANS SHALL BE
ADD ADDENDUM JAN JANITOR NEW INTERIOR GYP. BD. PARTITION SUBMITTED TO THE ARCHITECT IN WRITING PRIOR TO BID.
ADH ADHESIVE JC JANITOR'S CLOSET REFERENCE TO TYPE
ADJ ADJACENT 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH THE OWNER OF THE ADVANCE TOWER BUILDING ARCHITECTURE
ADJT ADJUSTABLE LAB LABORATORY TO BE DEMOLISHED REGARDING ALL PHASES OF THE WORK INCLUDING DEMOLITION, DEBRIS REMOVAL, DELIVERY OF NEW MATERIALS, WORK INTERIOR DESIGN
ALT ALTERNATE HOURS, UTILITY HOOKUPS, ETC., AND SHALL MAKE ALL ARRANGEMENTS TO FACILITATE THE TIMELY COMPLETION OF THE
LAM LAMINATED WORK.
ALUM ALUMINUM j�..� A R o 0 0 9 s 4 4
LAV LAVATORY TT��``�-``-```11 NEW INTERIOR GYP. BD. PARTITION WITH 2x4 BLOCKING, SEE PLAN FOR HEIGHT AND LOCATION. 4080 SW 84th AVENUE
ANC ANCHOR, ANCHORAGE LBL LABEL 4. ANY DAMAGE TO THE EXISTING BUILDING INCLUDING ITS INTERIOR, PARKING AREAS, IMMEDIATE EXTERIOR PUBLIC
ANOD ANODIZED LH LEFT HAND RIGHT-OF-WAYS, MECHANICAL SYSTEMS, ELEVATORS, FINISHES AT PUBLIC CORRIDORS, AND LOBBIES SHALL BE REPAIRED MIAMI, FLORIDA 33155
AP ACCESS PANEL 3
ELEVATION DATUM POINT AT CONTRACTORS EXPENSE. ,
05 220 8997
APPROX APPROXIMATE LT LIGHT
5. THE CONTRACTOR SHALL NOT DETERMINE ANY DIMENSION NOT SPECIFICALLY NOTED ON THE PLANS BY SCALING
ARCH ARCHITECTURAL MACH MACHINE SUCH PLANS. WRITTEN DIMENSIONS SHALL PREVAIL IN THE EVENT OF CONFLICT.
ASPH ASPHALT z5 DOOR NUMBER
AUTO AUTOMATIC MAG MAGAZINE 6. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL, COUNTY, STATE, AND FEDERAL
MAT MATERIAL(S) s ELEVATION LAWS REGULATING CONSTRUCTION, CONSTRUCTION SAFETY, AND LABOR.
AVG AVERAGE MAX MAXIMUM
MECH MECHANICAL(AL) SHEEP NUMBER
7. ALL WORK SHALL CONFORM TO THE SOUTH FLORIDA BUILDING CODE AND THE CITY OF SOUTH MIAMI ZONING CODE.
BOARD A-s
BD MFR MANUFACTURE(ER) 8. ANY REVISIONS NECESSARY DUE TO A VARIANCE BETWEEN APPLICABLE LAWS, ORDINANCES AND REGULATIONS, AND / ' '•�..
BKT BRACKET THESE SPECIFICATIONS AND DRAWINGS SHALL BE SUBMITTED TO CARLOS FIGUEROA, P.A. FOR APPROVAL BEFORE SUCH
BLDG BUILDING MIN MINIMUM
WORK IS PERFORMED. L u A"'ll S
BLKG BLOCKING MISC MISCELLANEOUS s SECTION
BM BEAM MTD MOUNTED A-2 SHEET NUMBER
CAB CABINET NA NOT APPLICABLE L
CG CORNER GUARD NIC NOT IN CONTRACT
CLG CEILING NO NUMBER �y� N 3M
DETAIL � {
CLR CLEARANCE) NOM NOMINAL A-s
SHEET NUMBER
CLO CLOSET NTS NOT TO SCALE
CMU CONCRETE MASONRY UNIT OC ON CENTER ALIGN ALIGN W/
ESTABLISHED SURFACE
COL COLUMN OD OUTSIDE DIAMETER
COMP COMPRESS(ED),(ION),(IBLE) OFF OFFICE
CONC CONCRETE OPNG OPENING 5 — DETAIL
CONF CONFERENCE OPP OPPOSITE A-4 —SHEET NUMBER
CONST CONSTRUCTION
CONT CONTINUOUS, CONTINUE PBD PARTICLE BOARD
CORR CORRIDOR PERF PERFORATE(D) DETAILED AREA
CTR COUNTER
P.LAM. PLASTIC LAMINATE
CPT CARPET
CT CERAMIC TILE PLAS PLASTER
CTR CENTER PNL PANEL
PTD PAINT(ED)
DBL DOUBLE PR PAIR E `�
PSF POUNDS PER SQUARE FOOT
DEMO DEMOLISH, DEMOLITION PSI POUNDS PER SQUARE INCH
DEPT DEPARTMENT PT DETAIL I
PT PRESSURE TREATED CIO
PTN PARTITION
DF DRINKING FOUNTAIN
DIAG DIAGONAL PLYWD PLYWOOD
DIA DIAMETER QTY QUANTITY
DIM DIMENSION
DISP DISPOSAL RAD RADIUS
DN DOWN RA. RETURN AIR
DR DOOR RE REINFORCE(D),(ING) d I
DW DISHWASHER REC RECESSED
DWG DRAWING REF REFERENCE ERING S L Si � D E � DRAWINGS ® �...,
DWR DRAWER REFR REFRIGERATOR
EA EACH REQ'D REQUIRED c n
EL ELEVATION REV REVISION(S),REVISED
ELEC ELECTRICAL RFL REFLECT(ED),(IVE),(OR) W
ELEV ELEVATOR RH RIGHT HAND SEE ENGINEERS DRAWINGS
EMERG EMERGENCY RL RAILING
EQ EQUAL RM ROOM `� W
EQUIP EQUIPMENT RO ROUGH OPENING
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER SC SOLID CORE A- 1 COVER
EXST EXISTING SCH SCHEDULE
EXT EXTERIOR SEC SECTION W �
sHT SHEET A- ABBREVIATIONS, SYMBOLS, � 4.4
FA FIRE ALARM SIM SIMILAR KEY PLAN, & INDEX
FAB FABRICATED SNT SEALANT
FAP FIRE ALARM PULL SPEC SPECIFICATIONS) A- 3 ARCHITECTURAL PLAN �
FD FLOOR DRAIN SQ SQUARE
FE FIRE EXTINGUISHER SS STAINLESS STEEL
A-4 REFLECTED CEILING ►�
FECR FIRE EXTINGUISHER CABINET REC. STD STANDARD
FECSR FIRE EXTINGUISHER CABINET SEMI-REC. STD SEATING ® ~
FF FINISHED FLOOR A- 5 FINISH SCHEDULES
FHC FIRE HOSE CABINET STL STEEL
FIN FINISHED) STO STORAGE
STR STRUCTURAL � DETAILS, & SPECIFICATIONS
FIXT FIXTURE SUSP SUSPENDED E I L X11 SYMBOLS Q0
FLG FLAMMABLE SYM SYMMETRY(ICAL)
FLG FLASHING
FLR FLOORING)
FOC FACE OF CONCRETE TEL TELEPHONE M- 1 MECHANICAL PLAN
FOF FACE OF FINISH TEMP TEMPERED
FLUOR FLUORESCENT THK THICK(NESS)
FO FRAME OPENING THR THRESHOLD E- 1 POWER PLAN
FOM FACE OF MASONRY TKBD TACKBOARD
FOS FACE OF STUDS TOIL TOILET
FR FIRE RATED TV TELEVISION 2' x 4' ACOUSTICAL TILE CEILING E - 2
LIGHTING PLAN
FS FULL SIZE TYP TYPICAL ELECTRICAL SPECIFICATIONS Revisions
FT FOOT, FEET TZ TERRAZO
FUR FURRED(ING)
FWC FABRIC WALLCOVERING UC UNDERCUT E-3 ELECTRICAL NOTES
GA GAGE, GAUGE UL UNDERWRITER'S LABORATORY
GC GENERAL CONTRACTOR LINO UNLESS NOTED OTHERWISE
2x2 FLUORESCENT LIGHT FIXTURE
GD GRADE, GRADING
GKT GASKET(ED) VB VINYL BASE
GL GLASS, GLAZING VCT VINYL COMPOSITION TILE
GMU GLASS MASONRY UNIT VERT VERTICAL
GN GENERAL NOTES VEST VESTIBULE
GWB GYPSUM WALLBOARD VWC VINYL WALLCOVERING
GYP.BD. GYPSUM BOARD
GALV GALVANIZED WC WATER CLOSET/TOILETS
WD WOOD
HC HOLLOW CORE WIN WINDOW
Job No. Sheet No.
HCP HANDICAPPED WO WITHOUT
HDB HARDBOARD WSCT WAINSCOT
HM HOLLOW METAL
Date
HR HOUR
HT HEIGHT 10/19/00 A- 2
HVAC HEATING/VENTILATING/AIR COND.
Drawn by
GSR
Appr. by
CF 2 of