Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
00-0832-014
EXHAUST DUCTWORK (E/D) 4 V .. - • Y minimum 6" U 07# GA, G/I, CONSTRUCTED, INSTALLED IN ACCORDANCE V1114 NrPA-96. LIQUID TIGHT, CONTIN- I ) Front view and section of hoods showing dimensions , overhang clearance from duct to ` L � , UQUSLY MELDED, RADIUS ELBOWS, PITCHED 1/4' PER FUT3T TOWARD HOOD WITH-OUT FORMING DIPS and location of all cooking appliances beneath the hood. If interior surface of ° OR TRAPS WHICH MIGHT COLLECT RESIDUES. ACCESS PANEL (A/P) APPROPRIATE SIZE TO PERMIT g PP enclosure. Fire rated enclosure +� '.1.•PROPER CLEANING, AT 12' INTERVALS, W/FULL PERIMETER FIRESTOP GASKET, SECURED WITH STUD. " deep fat fryers are installed, show minimum 16 " se aratio from top of hood throw (chase) to be continuous y DOLTS & VING NUTS, PROVIDE GREASE TROUGH V/DRAIN PIPE AND PLUG WHERE APPLICABLE, surface flames of adjacent cooking equipment . P n to naturally vented with Weather ,roorf othe curb and curb to be u � EXHAUST VELOCITY 1500 L 2200 FPM. P type louvers. ° 08 EXHAUST DUCTS CONTAINED IN FIRE; RATED ENCLOSURES, SHALL HAVE 6' MINIMUM CLEARANCE Z ) Type of cooking fuel. Solid fuel cooking appliances shall be provided with separate ° BETWEEN DUCTWORK & NON-COMBUSTIBLE MATERIALS, ` exhaust systems provided with fan override switch =h 3 ) If hood is listed or classified by a recognized testing ch tha t will m ' SUPPLY DUCTWORK I operate the exhaust fans whenever the duct tern 09 SUPPLY DUCTWORK CONSTRUCTED, INSTALLED IN ACCORDANCE WIT14 SMACNA STD. laboratory, give model number and test report of hood. if above 130o F. perature rises SUPPLY DUCTWORK (SID) SHALL BE 1124 GA. G/I . (PITTSBURG CONSIR'N) VELOCITY 1200/1500 FPM• hood is not listed by an approved testing laboratory , the ; RtIUND SUPPLY DUCTWORK <S/D>, rtI4ERF10FIN, ALUMINUM L FLEX, SUPPLY AIR VELA 1200/1500 FPM.- following is required: Kitchen exhaust ducts are not to be insulated ,v.,. • . iQ►�,,� •�C+ � IJL�'' as Maximum hood length 8 ft. per exhaust outlet. Following notes to be placed on draw b. Island hood open all four sides 150 CFM/Sq. of ing: • = l � ` �,,,yyy�. /i �/� / + r G',!;'� npgi Vol r�' p /� ,! Supply and exhaust ' entrance area. a' fans are interlocked with pilot � c . Canopy hood open three sides or less , 100 C1!'M/Sq . light in kitchen area. / b . Fire mode requires exhaust fan continues t o operate �:/ INSULATED CLASS 1 OR 0 FT EXIT3LE OR STEEL DUCT PER PI F t . ?out RX-r M SPECS. va/lE7Q 6 1100' 10 75 /lJ �' !� d. Canopy type hoods shall be at least 2 f and Supply fa n t. deep in PP Y n stops . �✓ U.L LISTED rusieLE LANK (165 F UNLESS OTHERWISE INDICAI the capture area, this area shall extend over the c. Hood exhaust fans shall operate whenever the Q CEILING RMV1110N Ik'MPER OR i1RE STOP FLAP WITI1 Gx2A/ 141 ' R+ ..� entire cooking 6g1,C �f '75 ��� ZS' g surface. extinguishing system is activated. CERAMIC FIOER INSULATION ADJUSTABLE FOR VOLUME CONI do Fixed pipe extinguishing systems in a single hazard 1 O THERIMAI. FIOER 8LMI(ET WREN CLG, OPG. C<CEEDS DAMPER 4) The length and width of kitchen hoods shall extend a minimum area shall be arranged for simultaneous automatic 5 OUTER CONE-GALVALUME $TELL of 6 inches beyond the cooking surface of tits a fiance over P O o eration u on act PP P i activation ti O n 0 f which an is � tl anyone e y are installed. Y o f the systems . STEEL GRILLE/PATTERN DEFLECTOR-REFER TO SCHEDULE Common exhaust duct for more than one hood would define e ' S) Show - type of construction of all walla , ceilings , roof a 811119le hazard area. Exception would be a secondary O MOUNTING SUPPORT rmic fire suppression system contained in the le J a structures and roof curbs that are within 18" of exhaust duct. e common exhaust O tw40ER WIRES (BY on4ERS) ' system. ,KITCHEN SHALL BE BALANCED TO BE NEGATIVE I s RATED CEILING WITH RESPECT TO THE DINING ROOM, t3 6) Liquid tight externally welded exhaust ducts to have all s to MOUNTING SCREWS dimensions , gauge, air quantities, E(Design between 1 5 0 0 and � ' tM F'Re ID(TINGUISH149 SWEI/ IS TO BE PROVIDED WITH CONTACT(S) TO STOP. FAJ(s) , NAI Lo R IN oUST4ES 0722A Oft 0116A u.1 CLASSIFIED iA ONTA:T(S) FOR INTERFACE YITII TIRE ALARM PANEL AS REQUIRED.F.P .M. ) Radius e l b o w s O n l y O n e X 18 U D C ducts. Vert O duCCWOCk shall be provided with an opening at top of the g (U.L SSSC) ADJJISTABLE RAD4ITION FIRE DAMPER ASSEMBLY UR EQUAL ('DYW441C' FIRE DWERS UNLESS vertical riser to permit descent . ;%1�l „'�» j OTHERWISE FUlEO). P p personnel s o n n e l a access e s s and -J"" I "" `--• '��'.'�' V 12 INSTALL. PER IMFGR'S RECOMMENDATIONS Horizontal ducts shall provide at least one 2U" X 20" opening x - O - -`"�-. - • ob to permit personnel entry. Whenever this i s not possible, openings l a r g e enough t o I t LAY- IN TYPE oIUSEN/RECISTR SM TNERtMP. 9LANKt permit thorough cleaning shall be 3 OVE LAP ADJACENT T-BRS IN LAY-I I A1UnON j 1� to F � ,' FOR DIFFUSER provided at 12 ft. intervals . All horizontal ducts to have "Rio PCrsRT CC LA143SIZEANONNWiW�A � 10 minimum 1/4 F t pitch toward the hood, without forming dips 1 17 I 1 a DAMPER A,ss ,Me SIL tTr AIR THROW P`A RI S OR EQUN. or traps which might collect residues. tft1ti DIXT 18 U.L CLASSIFIED CMS COUNO D)NAMIC'6DtATION AND//OR U•L CLASSIFIED BZIU FIRE WE0 CE)U DYNAMIC WTDNTIO � r- 7 ) Show make-up air ducts with dimensions and air quantity , and• ; tAx-N wTVSL�T sur;FrcF It4lIl4T DMTUSiR MMPER/UIFFUSER PACtVrCt:'S. fire damper if applicable. If replacement air is being 1•'--` 19 17 o 1 supplied by A/C system, show design criteria of air handling T-BAR LAY-IN C40UNG C-RiD MEMBER j 19 SUPPORT t3RA,NCH DUCT FEEDIFIO DIFi'U$ DUCT DROP PER /'l40 equipment. The replacement air quantity shall be adequate to ,I, UI Ucr IN 1 p Al . Vc DAMPER MANUFACTURER. WSEUOLY WST&JA S RUCs( «'' r-lO�� /� 'f� a�OL � prevent negative pressures in the room from exceeding 0. 02 in I '' 19 t' Llttir>�VU .•� ow� '�t,} (70/j, water column. Q 0 T SUS 8 ) Show roof mounted fans with minimum ae aration be If AC DESIGN I(E UIItL; YI?S N 2 O O IIISULAT)ON FOR DUCT, DAMPER FRA1ME. aFfA)SER p t w e e n D CT SMOKE DETECTOR COLLAR ETC. to K EDGE VAPOR IiAJ JERK SF.:ALED• ')L03 -S -,a •S I'�(� (' � exhaust and supply of 10 ' 0" side to side dimension. Exhaust -°°� �, P FI DAMPL'It S � ® PER SPECS. ANO EXTERNAL TO TT4ER►NL FIBER ©LANXt T. T , , fan to be minimum 40" above roof to discharge air. Roof to exhaust fans must be hinged on minimum 18" roof curb to SMOKE DAMPERS _ - � 5' � ------ permit full opening for exhaust duct maintenance . Specify FI ' ItATEDL'NCLOSURE ..� ELR ... .. At �--�fans by manufacturer, model number and design static FI s RATED ROOF/FLOOR F IRIN V DE. i•1 , ' pressure. All exhaust Fans sha•11 be listed as UL YLIITZ C IL1NG ASSEMBLY ~" N.T.S. �6c- C 1'T'�UT Subject 762 . fiQi FI E S•FOPPING a ' VApe V' 9) In one-story buildings where the , roof or roof ceiling SMOKE g MOTOR DOME .--. assembly Ls required to have a fire resistance rating, the I�II � ,t <10AI W Ii 14 / �/!G- �ldv/vd KITCHEN �►1I BALANCE -� D OLE exhaust duct shall be enclosed in a continuous enclosure 2 DISCHARGE APRON/UPPER AND LOWER WIND©AND 'Jb� extending from the ceiling above the hood, through any 3 VENTURI INLET NQLES; EQUIP. SUPPIYr` ` OU P f' 211 ,. ,, � �j • concealed spaces to or through the roof . ( NR RI:TU J NR EXITAU. T � � ��i +. «����:i..-.. M�V<E NR REMARKS }��t�lelf� •'• In all buildings more than ono story in. height the exhaust � INTERIOR WEATHER BAFFLE � i �'J STEEL IiAtdCING ANCLE. REFER TO Jt .�. HOOD DETAIL AND/Of? SC i AC-1 `�• m QajiA1.G- duct shall be enclosed in a continuous enclosure that VIII r / I EDULE CQ /� maintain the integrity of the fire separations � CENTRiFUCAL FAN WHEEL W/INTAKE FAN 11 Cl � 76 Y la G Lees ��Fd[1 l� _ B STEEL. MOUNTING BASE 1 DOUBLE d � 13LE LOCK NUT oNt: AC-2 AND ONE BELOW HANGING ANGLE) " F` D . 7 STEEL BttACED MAIN FASTENING ASSEMBLY °°'°"°"�"�°°° • • �r �Or`t�iS � 8 BALL BEARING MOTOR //;'3 DIA. ALL THREAD ROD F--1 y�. 2 SECURE0 TO STRUCTURE, CONFIRM �1 � SIZE PER 5TRUCT. DWGS, Li ' �- ,� ------- _ _ C� srP:EL MOTOR SUPPORT PLATE ' • 12 O RODS AND NUTS TO DE SUPPLIED MOTOR COMPARTMENT COOLING TUBE ANTI-VIBRATION MOUNTS tar GINGL14GL .CONTRACTOR. STEEL F-3 HANGING A11r, PRE- PUNCHED .. / LES TO l3E �r y ...........,. -„ -...�.�... �/,�'j'( 'IC. OD ` y""--~ ----'�ia.Cerc�M C, T1� © • S�Q�� 7 5 12 MOTOR AND BEARING FRAME 2 TEGRAL WITH I BODY & FURNISHED FV V..�.�.�.� C6&61�L �* 13 V-DELT AND PULLEYS REFER TO ARCH,/SIRUCTUI2AI. DWGS. �,�" , 'r`�y " "°'°"�'""" °"""°—"-- - 31, r FOR MVII()D IN WIiICN HANGER RODS 2 0 . VA UV G FAN � 16 15 � � 1 q FAN SHAFT AND BEARINGS ARE SECURED TO STRUCTURE. {' uuLL FAN BASE / .�.....".•.'..." ...- ,,,mow.. a.....�..� ...,.........,,,, Rte. . 11D FI V6- P67-6-- C6 4G/,(l� Q -.._/ / 15 CONDUIT GUIDE, n AVM• ; 22 y 16 WEATHER-TIGHT DISCONNECT SWITCH �..' _ 1N � ANGLE DETAIL P- A �, . �, 0 0 4 4C MIN. ' HINGE Kli . 1 EXTERNAL GREASE DRAIN PIPE - <IDENTICA� ASSENBLY ----CURB 1� 6 1© EXTERIOR GREASE COLLECTION PAN o f , ON OTHER SIDE Of CURD ___ � 17 19 FLEXIBLE WEATHERPROOF ELECTRIC CABLE ----------- --- -----�--- • 2.0 GT1' DU ' TA �► J�+�'•rl=u 0 21 18 - / - • r���. wlrhllu 1g o� � L,1zv r- L98 hs� �66A6E X00 e� 20 FLOATING HINGE ARRANGEMENT I :• ooh PtW�tJ n DUGT C,1l . r >r CoA1,P'1,1G. ___ .._ . II 21 HOLD OPEN RETAINER CHAIN i CT/D(J - 11S2I.F.�: wAL�--�. IZOO• `EJ�'-' �t RE(�L1u:ElEryT_.NR..4hA HVAC- SYSTEI,f SUFFICIENT-TO PRE1Nf NEGATIVE PRES5URE a "� 22 OF-LING HANDLES v/�1 �' t�ZJ tl'1 KIrCHE 1 FROLI 3 CURB MOUNTED JUNCTION BOX `I E�(GEEOING o.02 W.G. �p �2 NR IS TR. f EREp ROU,t DJACENT AREA TO KEEP KITCHEN UNDER NEGATIVE - 24 18" HIGH GALV. STEEL VENTILATED ROOF CURB i(1�oP PN' �/f 1}It ��� �'�/i:- 1 It111.IL1)dL PRESSURE��VE ED, ECf•TO ADJACENT AREA. � I �~ DDT , i T t1 25 U.L LISTED (YZHW) SUBJECT 762 't LUML i 0 too D �.U.57,6e G 'u) 126 PER NFPA 96--1994 r I 2fl e l f fit: C?P�IG- • ' 'f / S`102C- f�� 12 CLEARANCE PER. NFPA-96-1991 - C' �} 20 RATED ENCLOSURE WHERE REQUIREII, M 14,5-1,Q . till OUP '1 `� r'� r C ;• ` •"' , j �- CURB. 1DOMtj( UGC- G'FIhg�r VENTED CURB cti !<ITQHEN M -EAN-DE l / t3 at Ki6i�iv 1 .11+ ; - ... .. j1"G,UD ,J(/GT rJ t I °! f�r""`. I .r � ��j r.tJ d d•�Z�''• 10 -wee. i� DU 61 QWo fo r+t QO p :` p u ,�, /M7G-n w L Z 1 ` LASInI1G j� L 3' [Y1TINU(]US I S ,l� �—�"�� oil o '� I, � i pl,/ �+ ,.....,.sea•"'..=r� ,....yr `'t,r\�;l' ' _ 3`'A Irz � 5� ,•, C/ �ilJ� "�` c��lt`� `)�GO� 24 L C� D gbl�I�b 8f�+�dt-` FI(,T+*.P'S 11th / Z Dr 1(/I�L(. �fc j� OD SCCUQ� p ` _ rp- ,. .„ 2. �6C����G--��- - �► U ,1 14 00 0 • 12 vI `1 Co11.CGC0r I�.r1'' �,� �� It Wd D t� t d o� CU Q v Fb pr 1'C�7/Ulf eT Wi4� P }e. -T' X00/* f G G r Cu P _' Z Jx ��i tvaw fa'�X S' 0 r� 9 N "r er �' 4 r/ 0l2 " IL4?• �, F r - GAG -• '�8 I ► '�- I1,P'tI�C,. or -Titre ' 70 G �ri¢2 Foot 6,A6C� �1Ji • ILA PiiM Cx•IL is G-OVZ .�� - - Poop 1"R vS sect'l 0 I 1- 6-7'AC. PAP T /eZ i o�tJ ( ,� N pct our ��clr i prJ l G r7�S�G- rv/.�[.t, J 2. 0 1 U S7'61--cI l D�U r i AS �� � ; ..— 1 1�• l 'j �.� ���� ti.� �� �.+ /�,:. ? �� � fr+/�f6 r7" r �. gym/ 'J[ l�S�S O! ' INC. s �„ - .. ) w CONSULTING CIVIL 3, STAUCTURAL ENGINEER] � '.r" •, .y • -fjc�/�L .�'- � c �/// �> 326 S.W. 62 Am. ILL ti AS Tel: (3r5)2U'Is3G6u • Fax: 262=3368 1 � n �� 7 ! III' r