Loading...
00-0445-058 I11"d ( "vY .. P UMSING N 0 T E S : , i ` r � �. 1.. ALL WORK SHALL CO NFORM WITH TH E SOU TH F LOR I DA BUILDING CODE, NFPA, NEC, 23. CARRIERS: AND ALL OTHER APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS AND Lo ORDINANCES, FURNISH ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR THE A. ALL CARRIERS SHALL BE FULLY BOLTED TO THE FLOOR AND INSTALLED AS �► ; COMPLETION OF THE PLUMBING SYSTEMS DESCRIBED HEREIN AND SHOWN ON THE RECOMMENDED BY MANUFACTURER. ' � y s DRAWINGS. , W B. LAVATORIES: PROVIDE CARRIERS FOR ALL LAVATORIES NOT SUPPORTED BY y� ,t 2. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, INSPECTIONS, PLATES DIRECTLY FROM A MASONRY WALL. L► ,, TESTS, PERFORMANCE BONGS, FINES AND OTHER ITEMS AS REQUIRED FOR THE x �' ,�1ti►�� .•r � '� INSTALLATION OF THE COMPLETE PLUMBING SYSTEMS, AND SHALL BE RESPONSIBLE 24. VALVES NOTE: HORIZONTAL BUILDING DRAINAGE PIPING LESS THAN 3" NOMINAL DIAMETER SHALL FOR OBTAINING HIS OWN PERMIT. BE INSTALLED AT A SLOPE NOT LESS THAN 1/4" PER FOOT. ° A. GATE VALVES: ALL BRONZE CONSTRUCTION, SOLID WEDGE, CLASS 125, 200 PSIG 1 CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST NON-SHOCK WATER, THREADED ENDS, MILWAUKEE 115. '; PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. B. GLOBE VALVES: BRONZE CONSTRUCTION, CLASS 125, 200 PSIG NON-SHOCK 4. EXCEPT WHERE LONGER WARRANTIES ARE SPECIFIED FOR SPECIFIC EQUIPMENT, WATER, THREADED ENDS, MILWAUKEE 502. CONTRACTOR SHALL WARRANT ALL WORK TO BE FREE OF DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER FINAL WRITTEN ACCEPTANCE OF C, CHECK VALVES: BRONZE BODY, CLASS 125, 200 PSIG NON-SHOCK WATER, THE PROJECT BY THE OWNER. THREADED, MILWAUKEE 509; SOLDERED ENDS, MILWAUKEE 1509. • 5. PROVIDE ALL NECESSARY INSTRUCTIONS TO THE OWNER IN THE OPERATION OF THE 25, HANG PIPING FROM STRUCTURE ABOVE UTILIZING GALVANIZED HANGER RODS AND PLUMBING SYSTEMS BEFORE FINAL ACCEPTANCE. TRAPEZE OR CLEVIS HANGERS. FOR COPPER PIPING, RODS AND HANGERS SHALL BE COPPER CLAD. SUPPORT PIPING INDEPENDENTLY FROM EQUIPMENT. PLACE HANGERS 6. SUBMIT SHOP DRAWINGS FOR ALL MATERIALS AND EQUIPMENT FOR ACCEPTANCE OF AT EVERY PIPE CHANGE OF DIRECTION AND AT EACH SIDE OF SHUT OFF VALVES, THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLA- PROVIDE PROTECTING SHEET METAL SHIELDS FOR ALL INSULATED PIPING. Lij TION OF ANY EQUIPMENT AND MATERIALS. 26, PIPING TESTS 7, LABEL AND IDENTIFY ALL EQUIPMENT, PIPING AND VALVES. SUBMIT IDENTIFICATION SANITARY AND STORM PIPING: SUBJECT ENTIRE SYSTEM TO A HYDROSTATIC HEAD OF Q p SCHEME TO THE ARCHITECT/ENGINEER FOR APPROVAL. NO LESS THAN 10 FEET OF WATER EXCEPT FOR THE TOPMOST 10 FEET OF PIPE BY FILLING SYSTEM WITH WATER UP TO THE OVERFLOW POINT OF THE HIGHEST OPENING, U .- t( 8. PRODUCTS AND MATERIALS SPECIFIED BY TRADE NAME AND/OR MODEL ON THE 0 FOR A PERIOD OF TWO HOURS WITHOUT DROP IN WATER LEVEL. DRAWINGS ESTABLISH A STANDARD OF QUALITY, APPEARANCE, PERFORMANCE AND O (D • DIMENSIONS. CONTRACTOR SHALL BASE HIS BID ON THOSE ITEMS, WHICH SHALL BE DOMESTIC WATER PIPING: SUBJECT THE ENTIRE SYSTEM TO A HYDROSTATIC 4+ 1 M ^ CONSIDERED TO ESTABLISH A STANDARD BASIS OF BIDDING, REQUESTS FOR SUBSTITUTION SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT ENGINEER PRESSURE OF NO LESS THAN 150 PSIG FOR A PERIOD OF TWO HOURS WITHOUT LOSS DEMONSTRATING THAT THE PROPOSED PRODUCT IS COMPARABLE, AND THAT BASIC IN PRESSURE. (f U w DESIGN, CONSTRUCTION STANDARDS, QUALITY AND WARRANTIES ARE EQUAL OR 27, TEST ALL EQUIPMENT TO DEMONSTRATE PROPER FUNCTIONING AND CAPACITY, Q ®= •• O BETTER THAN THE PRODUCT SPECIFIED, CONTRACTOR SHALL BE RESPONSIBLE FOR - Q) 0- LA; t ANY CHANGE IN THE WORK REQUIRED BY OTHER TRADES AND'SHALL PAY FOR ANY 28 PROVIDE SHOCK ABSORBERS DIELECTRIC FITTINGS HANGERS AND INSERTS TRAP �RE- e EXPENSES INCURRED DUE TO THE CONTRACTOR'S REQUEST FOR REVISIONS OR SEALERS, VACUUM BREAKERS, STRAINERS, VALVES, ETC., FOR COMPLETE AND SUBSTITUTIONS. OPERABLE PLUMBING SYSTEMS AS REQUIRED BY CODE AND AS INDICATED ON PLANS. PROVIDE UNIONS AND FLANGES AT ALL CONNECTIONS TO EQUIPMENT FOR EASY Z r' 9. CONTRACTOR SHALL MAINTAIN A SET OF DRAWINGS AT THE PROJECT SITE WITH UP TO- MAINTENANCE AND DISMANTLING. PROVIDE ESCUTCHEONS AT ALL PIPE PENETRATIONS [� • --- z O) DATE INFORMATION ON AS-BUILT CONDITIONS INDICATING WITH COLORED PENS ALL OF WALLS, PARTITIONS, FLOORS AND CEILINGS. cD ++ CHANGES AND DEVIATIONS FROM THE CONTRACT DRAWINGS, THIS SET OF PRINTS 3" VTR LL.J SHALL BE TURNED OVER TO THE ARCHITECT/ENGINEER AT THE COMPLETION OF THE 29, PROVIDE SHORING AND BRACING IN ACCORDANCE WITH STATE AND LOCAL REGULA- J '� PROJECT AS APRE-REQUISITE FOR FINAL PAYMENT. TIONS FOR THE PROTECTION OF PERSONNEL AND UTILITIES WHERE EXCAVATIONS ARE I Qp I U to 10. PROVIDE ALL NEW MATERIALS OF AMERICAN MANUFACTURE, BEARING THE U.L. LABEL MADE. PROVIDE ALL LABOR AND MATERIALS IN CONNECTION WITH EXCAVATING,TRENCHING, DE-WATERING, FILLING, BACKFILLING, COMPACTING, ETC., UNDER THIS W AS APPLICABLE. PROVIDE SUPPLEMENTAL MATERIALS NOT SPECIFICALLY NOTED DIVISION (MECHANICAL). O HEREIN, BUT REQUIRED TO COMPLETE THE INSTALLATION IN ACCORDANCE WITH THE I INTENT OF THE CONTRACT DRAWINGS, AT NO ADDITIONAL COST TO THE OWNER, 1 11, FURNISH ALL NECESSARY ACCESS PANELS TO CONTROL VALVES, CLLANOUTS, WATER ( I HAMMER ARRESTORS, ETC., TO THE GENERAL CONTRACTOR, FOR INSTALLATION UNDER 3 f/ VTR Col. THE GENERAL TRADES. j L 3"FD I 12, ALL WORK SHALL BE FIELD CHECKED BEFORE INSTALLATION AND COORDINATED WITH BEAM I Q ALL OTHER TRADES, THE CONTRACT DRAWINGS ARE DIAGRAMMATIC AND INTENDED ( 3" TO DEPICT APPROXIMATE EQUIPMENT LOCATIONS AND ARRANGEMENTS, NOT SHOW P..� " ANY MINOR DETAIL. PLANS SHALL NOT BE SCALED: REFER TO THE ARCHITECTURAL ?__2 u AND STRUCTURAL DRAWINGS FOR DIMENSIONS. '3"FD 4" „ 13. OFFSET PIPING AS REQUIRED TO CLEAR BUILDING STRUCTURE, DUCTWORK, ETC. AS CO 4 3 SHOWN ON DRAWINGS AND AS REQUIRED BY FIELD CONDITIONS. 2„ � 3 I ' I 14. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT 3" JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. ' P 1 15. PLUMBING FIXTURES ARE NOT INCLUDED UNDER THIS CONTRACT. PROVIDE COMPLETE � ROUGH-IN (WATER AND DRAINAGE) FOR ALL PLUMBING FIXTURES, 3"FD MAX, 18" 16, EACH PLUMBING FIXTURE SHALL BE PROVIDED WITH AIR CHAMBERS AS PER S.F.B.C. I 17. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE (3" PROVIDED TO CONNECT BOTH TYPES OF PIPES. I n I L_L._ 18, PROVIDE PIPING AS FOLLOWS: 3„ 2 I 0 A. DOMESTIC COLD WATER PIPING: �1 UNDERGROUND:' TYPE K SEAMLESS HARD DRAWN COPPER TUBE WITH CAST 3" COPPER ALLOY OR WROUGHT SOLDER JOINT FITTINGS. +, � ABOVE GROUND; TYPE L SEAMLESS HARP DRAWN COPPER TUBE WITH CAST Z �4 I COPPER ALLOY OR WROUGHT SOLDER JOINT FITTINGS, � 3 W z SOLDER USED IN JOINTS SHALL BE 100% LEAD-FREE. Q V B. STORM WATER, SANITARY WASTE AND VENT PIPING: I co CO Q ® N „ 3"Fp S �' .� V UNDERGROUND AND ABOVE GROUND; PVC DWV PIPE AND FITTINGS WITH 2 3 C SOLVENT SOLDERED JOINTS. I I 4" 3 P-- 4" FCO 19. DISINFECT ALL DOMESTIC WATER PIPING IN ACCORDANCE WITH SFBC AND AWWA 3"FD _p_1 STANDARDS, ( 0 4„ 20, THERMAL INSULATION 24 F.U. PLUG FOR FUTURE EXTENSION BY ( n O A. HORIZONTAL STORM DRAINAGE PIPING RUNNING PARALLEL TO THE ROOF: 1/2" OTHERS (STARBUCK$ COFFEE SHOP) THICK PRE-MOLDED GLASS FIBER PIPE INSULATION WITH SELF-ADHESIVE UNDER A SEPARATE CONTRACT. ( 3 3„ 4" M JACKET. 4" 11 21. CLEANOUTS 63 F.U. , Q A. WALL CLEANOUT: JOSAM SERIES 58790 WITH THREADED PLUG AND VANDAL 4" 3„FD 3 I FCO P�1 PROOF STAINLESS STEEL ACCESS COVER PLATE. x 36 F,U. (� TO CITY SEWER, B. FLOOR CLEANOUT: SEE CIVIL DRAWINGS. ' 3„ FCO 60 F.U. INTERIOR; JOSAM SERIES 56020 WITH VANDAL PROOF COVER. 3 4 R? EXTERIOR; JOSAM SERIES 58440 WITH VANDAL PROOF COVER. PROVIDE CLEAN-OUTS IN HORIZONTAL PIPING AT INTERVALS REQUIRED BY CODE, AT 4” 3" FCO THE BOTTOM OF ALL WASTE STACKS AND RISERS, AND AT EVERY CHANGE IN F. DIRECTION, AND WHERE INDICATED ON DRAWINGS. . 22. DRAINS; A. TOILET ROOM FLOOR DRAIN (FD-1): JOSAM NO. 30000-6S-50, 6" X '6" NICKEL— B DA APRIL 3, 2000 .r�i.�ir.,.��,�.r..rr."r�.r®erss BRONZE STRAINER AND TRAP PRIMER CONNECTION, B. TRASH ROOM DRAIN: JOSAM N0, 34720 COATED CAST IRON FLOOR DRAIN WITH ,J,Q�„j�,000-06 TWO-PIECE BODY, EXTRA HEAVY DUTY ROUND CAST IRON GRATE AND REMOVABLE SEDIMENT BUCKET. _. gDWN BY..,r•------J.S �1/ T C. ROOF DRAIN (RD-1): JOSAM N0. 21005, DRAIN RECEIVER, SUPPORTING RING AND INK 9Yr„",,,,,.,.r, L GASKET, DECK CLAMP ASSEMBLY, C.I. DOME. - - -E N V' D N T � I SCALE : N .T. S. P - 2 A I J