Loading...
00-0445-052 • • Y.._ • • • U U Y D Y • L • O PANEL PANEL PANEL ` .Y `Y• G Y • U 1: U YY U G 150A BREAKER FOR SPACE #203. 150A BREAKER FOR SPACE #202. D' 'F' 'G' (METER BELOW) (METER BELOW) 150A BREAKER FOR SPACE #201, °Y (METER BELOW) Y . � G 2ND FLOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MAIN 1 OF 1 150A BREAKER FOR SPACE #101. MARICE CHAEL, A.I.A. AR0014885 (METER BELOW) 400A METER FOR THOMAS T. COOPER, A.I.A. AR4486 8' GUTTER 400A BREAKER SPACE #103 150A BREAKER FOR SPACE #102, (METER BELOW) FOR SPACE #103 z � n 400A METER FOR HOUSE � � � PANEL AND ELEVATOR ONE 2" EMPTY PVC. PROVIDE C PULL STRINGS F N B 8 B 8 B f GUTTER 6" X 6" X 4, 3 � PAN, i � �r—� EL MAIN 1 0 F 3 -� i X19 H, PANEL PANEL PANEL PANEL 4' GUTTER 1,200A,30 _ MAN' 8 'C' 1C1' 'B' 'A' • ELEV. MAIN 0 2 0 0 2_- 0 0 0 f (MAIN 2 OF 3) TELEPHONE BACKBOARD �-- 'I N 8'H x 4'W x 3/4"p �- ® TENANT TENANT TENANT TENANT TENANT TENANT B /� • 201 202 203 101 102 103 HOUSE l MAIN 3 ,2 4 TENANT TENANT TENANT 200A BREAKER , _ 103 102 101 MAIN 3 OF 3 TO TELEPHONE COMPANY ,� � OF 3 �� -� ( ) POINT OF CONNECTION, N GUTTER 12" X 12" X 8' � TO ELEVATOR FIELD VERIFY LOCATION LIGHT TiMER 'T1' MACH. ROOM �—.2�! HOUSE PANEL 'H' � � [] M I t`0 U3 O TO FPL POINT TO FPL POINT It co SERVICE L OF SE CE F SERVICE/ 0 SE CE - O I— a) L M 2"MIN, ?p' MIN. Q �'^� M tf) GROUNDING ELECTRODE #4 AWG OR V) Q v 5/8"x10' GROUNDING ROD LARGER BARE COPPER CONDUCTOR �j �_ .� 2 OR STEEL REINFORCING BAR OR ROD ELECTRICAL RISER Q; v > W x a ELECTRICAL ROOM LAYOUT NOT LESS THAN }f DIAM. NTS CJ p O U " " $ r. SCALE: 1/2 = 1 -0 ��D wAT�+c A'•s� boN��D � �-- u7 '- \ CROSS REFERENCE NOTES . ,..� V) °,_° �- • The ampacity of the THHN conductors has been determined on the 7.- PANEL "B" ; 225 amp, Main Lugs, 1201208v, 3-¢, with an /C breaker Z Q O 0 basis of 751 C rating. combination 22,000 IC amps, ITE mode! G4242ML3225 .Branch circuit �T� V) All conductors shall be copper. breakers QP. .- ELECTiW SYMBOLS 0 Installation shall comply with the NEC, the South Florida Building ^ U Code and other applicable National, State and Local codes. 8,- PANEL "C" : 400 amp, Main Lugs, 1201208v, 3-¢, with an iC breaker ® �, 00 O Ln All equipment shall be new and UL listed. combination 22,000 IC amps, ITE mode! E4242ML3400FCU .Branch o I GROUNDING TYPE DUPLEX RECEPTACLE. INSTALL AT 18" AFF, U.O.N. circuit breakers QP. Provide panel with double lugs kit. ® ') W VICE GROUNDING TYPE SINGLE RECEPTACLE. INSTALL AT 18" AFF, U.O.N. 1.- #1: Three (3) sets: Each set ER4-600 THWN in 4"PVC Sch 40 fora 8A.-PANEL "Cl" : 400 amp, Main Lugs, 1201208v, 3-0, with an /C breaker Lj total service ampacity of 1,260 Amps. (based on 75` C) combination IC amps, ITE model E4242ML3400FCU .Branch circuit breakers rs QP.QP. 150A 150A 150A GFCI DUPLEX RECEPTACLE, INSTALL AT 18" AFF, U,O.N. BREAK BREAK BREAK MAIN 1 OF 1 � 1A.- #2.' 4 # 250 THWN in 3" PVC Sch 40 for a service ampacity of 255 400A BREAKER Amps. (based on 75` C) 9.- PANEL "D" : 225 amp, Main Lugs, 1201208v, 3-¢, with an IC breaker ® SPECIAL PURPOSE RECEPTACLE TO MATCH EQUIPMENT PLUG, combination 22,000 /C amps, ITE model G4242ML3225 .Branch circuit 0 INSTALL AT 18" AFF, U.O.N. MAIN SERVICE BREAKERS breakers QP. 0 J JUNCTION BOX. 2.- MAIN # 1: A 1,200 amp main breaker, 1201208v, 3¢, /C= 42,000A, make ITE model NXD6. Provide permanent black plaque labeled "Main 10,-PANEL "F" : 225 amp, Main Lugs, 1201208v, 3-0, with an IC breaker 000 l of 3 "as per NEC article 230-2. combination 22,000 /C amps, ITE model G4242ML3225 .Branch circuit SAFETY DISCONNECT SWITCH breakers QP. 400A 21.- MAIN#2 (Elev. Main):. 200 Amps heavy duty disconnect switch, 30, METER Z► PHONE OUTLET. RUN 3/4" CONDUIT AND STUB UP 6" ABOVE CEILING. make ITE model SN424, with three 175 Amps dual element time delay 11- PANEL "G" : 225 amp, Main Lugs, 1201208v, 3-q., with an lC breaker fuses Provide permanent black plaque labeled "Elev. Man " as per combination 22,000 /C amps, ITE model G4242ML3225 .Branch circuit breakers QP. DENOTES FIXTURE TYPE W. SEE LIGHTING FIXTURE SCHEDULE NEC article 230-2. 12" x 12" x 8' GUTTER 24.- MAIN#3:A 100 amp main breaker, 1201208v, 3¢, /C= 42,000A, make GUTTERS $ LIGHTING SWITCH. INSTALL AT 48" AFF, U.O.N. ITE model QJ2H. Provide permanent black plaque labeled"Main 3 of 3 12.-Gutter 12'x 12 "x 8'. "as per NEC article 230-2. 13.-Gutter 6"x 6 "x 4'. $3 THREE-WAY LIGHTING SWITCH. INSTALL AT 48" AFF, U.O.N. DISTRIBUTION BREAKERS WIRING 3.- 150 amp breaker, 1201208v, 3¢, /C=42,000A, make ITE model QJ2H, 14.- Three sets, each set : 44 600 THHN (A0,B0,CO3 Neutral ) + 1 # 1/0 men ELECTRIC PANEL. SEE ELECTRICAL RISER AND PANEL SCHEDULE SHEETS THHN(gnd)in 3-1/2"C. 4.- 400 amp breaker, 120/208v, 3¢, /C= 65,000A, make ITE model JXD2. 15.-4# 1/0 THHN(A0,B0 Co,Neutral) + 1-#6 THHN(gnd)in 2"C. ELECTRICAL ROOM EAST WALL 16.-4#600 THHN(A0,B0 CO3 Neutral) + 14 3 THHN(gnd)in 3-1/2"C. SCALE: 1/2" = 1'-0" O DOWNLIGHT FIXTURE 17.-4#250 THHN A ,8 G ,Neutral i PANELS INSIDE ELECTRIC ROOM ( � � � ) n 2-112"C. 5.- PANEL "H" : 225 amp, Main Lugs , 1201208v, 3-0, with an IC breaker 18.-4#210 THHN(A0,B0 Co,Neutral) + 14 6 THHN(gnd)in 2"C. e—; 4' FLUORESCENT STRIP combination 42,000 IC amps, ITE model G4242ML3225. Branch circuit 19.-4#3 THHN(A0,B0 Co,Neutral) + 1-#8 THHN(gnd)in 1-1/4"C. breakers QP. ^ . EMERGENCY LIGHT W/BATTERY BACKUP GROUNDING h"�•1 FLOOR PANELS 20.- 1 #340 THHN in 3/4"PVC, 6.- PANEL "A" : 225 amp, Main Lugs, 1201208v, 3-¢, with an /C breaker 25.- 1 #2 THHN in 112"P VC. ® EXIT LIGHT W/BATTERY BACKUP combination 22,000 /C amps, ITE model G4242ML3225 .Branch circuit breakers QP. OTHER EQUIPMENT 22.-200 Amps meter, 30. WALL MOUNTED INCANDESCENT FIXTURE 23.400 Amps meter, 30. 6" x 6" x 4' GUTTER 4' WRAPAROUND FLUORESCENT FIXTURE CEILING MOUNTED FAN WITH LIGHTS. w PANEL MAIN MAIN 2 150A 150A SELECTED BY ARCH/OWNER Q Q 0 H' OF 3 OF 3 Q BREAK BREAK p U WP WEATHERPROOF ® N M TOILET EXHAUST FAN • Lj W O Y • L� :3 400A I • �p MOTE 0 a Q 00 W � V) z � Z o W B-1,3 6' HIGH COND, UNIT Service #1 Load Calculation ENCLOSURE C-1,3 H-1,3 F-1,3 SEE ARCH, DWGS, Load A B C Neutral 2 Main 1 of 3 1, 150 1, 150 1, 150 1,038 Q� CU-7 ; i Total Load 1,150 1,150 1,150 1,038 � ELECTRICAL ROOM NORTH WALL cu-6 H-11 �^ SCALE: 1/2" = 1'-0" CU-5 � i®II E H-11 � CU-1 L3 Service #2 Load Calculation o CU-4 Load A B C Neutral vi � Main 2 of 3 (Eiev. Main 129 129 129 0 't x NOTES Main 3 of 3 100 100 100 85 pF-- 1.— FOR EXACT LOCATION OF HVAC EQUIPMENT CONSULT MECHANICAL DRAWINGS, 4V 3 2,- ALL ROOF MOUNTED ELECTRICAL DEVICES TO BE WEATHERPROOF, 7 Total Load 229 229 229 85 3 G-1,3 A-1,3 D-1,3 3.- FROM TELEPHONE BACKBOARD RUN ONE EMPTY 1"PVC TO EACH SPACE, FOR FUTURE TENANTS O� CO DUI�S EINSIQDEIPMENANTPSPACES,PULL STRINGS, CONSULT WITH OWNER FOR FINAL LOCATION OF PARTIAL ROOF PLAN DATE: APRIL 3, 2,a� 4.- FROM TELEPHONE BACKBOARD RUN ONE #6 CU GROUNDING CONDUCTOR TO MAIN GROUNDING SCALE 1/8" = 1'-0" � JOB N0: V)O `ELECTRODE SYSTEM INSIDE ELECTRICAL ROOM, w V" 5.- FOR EXACT LOCATION OF EQUIPMENT AND DEVICES INSIDE ELEVATOR MACHINE ROOM AND PIT, DWN BY: A5• VERIFY WITH ELEVATOR CONSULTANT. r� 0 a`L 6.- CONSULT WITH OWNER/ARCHITECT FOR FINAL LOCATION OF PANEL 'C' IN SPACE #103, NOT TO ''` >a' "' ' CHK BY; TA p INTERFERE WITH LOCATION OF FUTURE RESTROOMS IN THAT SPACE. C.' A. IQ U 7.- ALL EXIT AND EMERGENCY LIGHTS TO BE CONNECTED TO INDICATED CIRCUITS AHEAD OF ANY �* ;� �r�%'.'l, REVISION: SWITCH. �:. ` F/ 4 �� ? ,�,` TOMAS C " RMSTR U',�P.A: ENGINEERING ,QNSU 7' Ile # ,5 5600 S.W. 135ti 4 e., S•- ,W i rel (303)386 7J 5?' v{ (OS) j 1 -T E�4 TOAIAS','J. ARMSTROrQ ,t? E.E. PE .974,. ' sit=, �,�' �l..,�• ..... ,. ,