00-0374-020 a! t t U p F'LUME31NG f=IXtURE SCHEDULE PLUMBING GENERAL NOTE6 AND SPECIFICATIONS: CAR.LOS FLUME31NG 4 plFING LEGEND I. A. SCOPE OF WoRK: FIGUEROA MARK TRAP FIXTURE HOT COLD �.ltctirrr;�:�r SIZE UNITS WATER WATER THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY WOLLN ON THE WC 3" 4 _ 1/211 DRAWING8, SPECIFIED HEREIN AND/OR AS NEEDED FOR A COMPLETE RAIN WATER LEADER SYSTEM, INCLUDING BUT NOT NECESSARILY LIMITED TO: -CIF-- UNION CONNECTION ® ROOF DRAIN --�I-- FLANGED CONNECTION rK5K AV 11/211 1 1/211 1/211 I. DOMESTIC COLD AND HOT WATER PIPING SYSTEM$ ® FLOOR DRAIN 2. SANITARY DRAIN AND VENT SYSTEMS ECCENTRIC REDUCER �„ 3. PLUMBING FIXTURES AND TRIM ❑ AREA BASIN 11 2 I/2 1/2 11 4. AIR CONDITIONING CONDENSATE DRAIN$ ' — CONCENTRIC REDUCER CATCH BASIN 5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER [] +ASK 11/2" 2 '/2 11 1/ 6. PIPING INSULATION FIRE DEPARTMENT SIAMESE CONNECTION 2 I. SUPPORTS AND HANGER$ -4• HOSE BIBS W/VACUUM BREAKER UR 210 4 --- 3i4 B. ALL PLUMBING WORK 5N p a — ALL BE PERFORMED IN ACCORDANCE WITH THE LATEST OO PENDANT TYPE SPRINKLER HEAD ROOF MANIFOLD EDITION OF THE "SOUTH FLORIDA BUILDING CODE" CH. 46 LOCAL ORDINANCEStcFirrsc r�x� 3 CSK 11/2" 2 1/211 1/211 AND IN COMPLIANCE WITH THE "FLORIDA ENERGY EmlCIENCY CODE FOR 1 - rHRIOM VESrvrr -� SIDEWALL SPRINKLER HEAD -t��'---- BASKET STRAINER BUILDING GON$TRUCTION", AND "NR8" REGULATIONS. IN THE EVENT OF 'r T' _ - - GATE VALVE NB _ 1/2" W/VALVE 4 CONFLICT BETWEEN ANY CODE OR REGULATIONS, THE MORE STRINGENT 'z CO O O 9 s3 4 4 — �"- BALANCING PLUG "Y" STRAINER VAC. BREAKER REQUIREMENTS WILL GOVERN. 44, 4 SW 84th�vLNIUF_ --�-- 7,FLORIDA. 33155 FD 3° 2. CONTRACTOR t0 VERIFY AT SITE THE LOCATION, ELEVATION AND SIZE OF ALL \\�` s��s» - - ANGLE VALVE 3 --- 1/2" FOR RI=SEAL EXISTING LINES FOR CONNECTION BEFORE INSTALLATION OF ANY PIPING, �� -�- OS & Y VALVE \ • r FLOAT VALVE .� CHECK VALVE(NON-SLAM) � .� • ,•, 1 w 3. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS " , —��-- FLEXIBLE CONNECTION(12" PIPE DIAMETERS - C7 PRESSURE 6c TEMPERATURE RELIEF VALVE OR SHOCK AB50RBER5 A3 INDICATED ON PLANS, UP TO 24" MAX.) .. 1 �--- BALL VALVE FLOOR GLEAN-OUT 4. PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH THE APPROVED MATERIALS, ' ` V j` BUTTERFLY VALVE/ AGA APP. GAS VALVE SHALL HAVE FLOOR CLEAN-OUT SH SMOOTH IMPERVIOUS SURFACES AND ALL BE FREE FROM DEFECTS «' ® HW SHUT-OFF VALVE AND CONCEALED FOULING SURPACE5, ALL FIXTURE TRIM t0 BE CNROM '! �'E °�{' '• ' ,` - WALL CLEAN OUT E PLATED. FIXTURES SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC. ® CW SHUT-OFF VALVE DIRECTION OF FLOW CAP FOR FUTURE BUILDING SANITARY DRAIN OR SEWER CONNECTION SOLAR 5. WASTE LINES t0 BE PVC SCH. 40. SLOPE ALL UNDERGROUND SANITARY PIPES A/C AIR CONDITIONING CONDENSATE DRAIN OR HEAT RECOVERY 3" AND ABOVE AT 1/8"/FT. ALL PIPES 2" ! SMALLER SLOPE AT '/4"/FT. COLD WATER LINE V) — - - HOT WATER LINE 6. PROVIDE FULLY ACCE851BL,E CLEAN OUTS ON SANITARY AND ANY WASTE PIPING AT w GATE VALVE GATE VALVE EVERY CHANGE OF DIRECTION, AND At BOTTOM OF STACKS. CLEAN OUT LOCATIONS — - F - - HOT WATER RECIRCULATION LINE HEAT TRAP r l AND SIZES ON HORIZONTAL LINES SHALL BE ACCORDING TO CODE. O F FIRE LINE Z COLD WATER, 3/4" '1. VENT LINES t0 EXTEND g" MIN, ABOVE ROOF AND FLASH WITH LE=AD, rz�, G HW. t0 FIXTURES 8. WATER PIPE BELOW GROUND SHALL BE COPPER TYPE "K" ABOVE GROUND t0 BE v GAS LINE(NATURAL OR UP) PRESr,�,l� � TEMPERATURE COPPER TYPE "L". OR APPROVED GPVC NO JOINTS ALLOUJED UN HOT WATER 3/4' I�LIEF VALVE (ASME AFrRvo.) DER SLAB SANITARY VENT LINE UNION SD STORM DRAIN 5. PIPING UNION A. SUPPORT ALL PIPE FROM SOUND PORTIONS OF STRUCTURE AND AT PROPER INTERVALS ACCORDING WITH CODE. a B. PROVIDE SLEEVES FOR ALL PIPING PA88ING THROUGH FOUNDATION SLABS OR 3/4" Cu RELIEF DISCHARGE MASONRY WALLS, CAULK OPENINGS BETWEEN PIPE AND SLEEVES. s WATER NEATER EF. LINE, TO OUTSIDE GREEN 0 LO BOY g 40 GAL. F. ac R8 AREA, TERMINATE 6" C. WHERE EXPOSED PIPES PASS THROUGH FLOO , WALLS, OR CEILINGS, PROVIDE AE OVE FIN. GRADE ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUTSIDE DIAMETER TO COVER THE SLEEVED OPENINGS FOR THE PIPER, PROVIDE EMEgG. DRAIN PAN CHROMIUM PLATED ESCUTCHEONS IN BATHROOMS. 10. INSPECTIONS AND TESTS A. CONTRACTOR SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS t0 THE w AUTHORITIES HAVING JURISDICTION, AS THE WORK PROGRE55E5. ALL (h SYSTEMS SHALL BE TESTED BY CODE AND/OR LOCAL REGULATIONS. VV U WALL BRACKET----_ p U B. DRAINAGE PIPING: BEFORE INSTALLATION OF ANY DRAINS, THE ENDS OF HN SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH THE WATER TO THE 1 HIGHEST POINT AND ALLOWED TO 5TAND UNTIL INSPECTION IS MADE BY N WL HEATER ( J(� DIAGRAM H 004ER REPRESENTATIVE, r-1 NO SCALE II. STERILIZE ALL WATER LINES WITH A MIXTURE OF TWO (2) POUNDS LIME t0 EACH 1.000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE). RETAIN MIXTURE IN PIPES 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER BEFORE PLACING IN SERVICE. 12. COMPLETE SYSTEM, FIXTURES AND EQUIPMENT 5HALL BE GIVEN AN IN-SERVICE TEST F0 AFTER COMPLETION OF THE INSTALLATION. M w Q EXTRA DEEP HEAVY-DUCTY O a ACCESS FRAME SECURED COVER GASKETED ABS AUTOMATIC PRIMER VALVE (� FLOOR CLEANOUT PLUG SURFACE WITH INTEGRAL VACUUM • ' • ' BREAKER [� •'; �� .. a °'• ,►. ` , M � W ANCHOR DOMESTIC WATER LINE FLANGES THREADED COUNTERSUNK Revl5lons CLEANOUT PLUG 1�:. LINE TO TRAP Z COVER Q 0 0 FLOOR DRAIN m r� COUNTER INK SCREW 3 U) ENNGTH TANDARD DRAIN TO SEWER LINE Drawn : A r. Y b --� LONGER LENGTHS CNF CF c OPT15NAL AT EXTRA D j CLEANOUT DETAILS ate : 0312 I/00 U N.T.S. Scale :A5 noted rl r PL.00R DRAIN RESEAL Job No. LO Sheet: v NO SCALE U GUERRERO/GONZALEZ P-2 H ENGINEERS, INC. =01 C. (G5 Cu.rraro, P.L "'°'W L Of: I Sheets Ro1od L �1f� P/5236 EI•c{Acd Enp. Ue. //11051 4300 S.W. 73rd Al!Cl/VE• S . 107A wok Florida 33156 TA (306) 202-3044, Fax (305) 262—e211